WARN00DEU Site Information Form (site log) International GNSS Service See Instructions at: ftp://igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Peter Franke Date Prepared : 2019-05-14 Report Type : UPDATE If Update: Previous Site Log : warn_20190205.log Modified/Added Sections : 3.10, 3.11, 4.5, 4.6 1. Site Identification of the GNSS Monument Site Name : Warnemuende Four Character ID : WARN Monument Inscription : IERS DOMES Number : 14277M002 CDP Number : Monument Description : STEEL MAST Height of the Monument : 3.6 m Monument Foundation : STEEL MAST ANCHORED TO THE ROOF Foundation Depth : Marker Description : SURVEY MARKER BOLT ON A STEEL MAST Date Installed : 2003-02-11T12:00Z Geologic Characteristic : Bedrock Type : Bedrock Condition : Fracture Spacing : Fault zones nearby : Distance/activity : Additional Information : Survey Marker Bolt on a steel mast, : fastened on a wall on the roof : of the building for the branch office : of the Wasser- und Schifffahrtsamt : in Warnemuende. The Survey Marker Bolt : is 1.2 m above the roof and 9,65 m : above the ground. 2. Site Location Information City or Town : Rostock-Warnemuende State or Province : Mecklenburg-Vorpommern Country : Germany Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : 3658785.930 Y coordinate (m) : 784470.840 Z coordinate (m) : 5147870.560 Latitude (N is +) : +541011.23 Longitude (E is +) : +0120605.13 Elevation (m,ellips.) : 50.8 Additional Information : 3. GNSS Receiver Information 3.1 Receiver Type : JPS LEGACY Satellite System : GPS+GLO Serial Number : AF2ETZ85Y4G Firmware Version : E_GGD_2/2.2 Elevation Cutoff Setting : 5 deg Date Installed : 2003-02-11T12:00Z Date Removed : 2003-12-05T10:00Z Temperature Stabiliz. : Additional Information : Additional Number LE 5800 on the type level 3.2 Receiver Type : JPS LEGACY Satellite System : GPS+GLO Serial Number : AF2ETZ85Y4G Firmware Version : E_GGD_2/2.3p3 Elevation Cutoff Setting : 5 deg Date Installed : 2003-12-05T10:00Z Date Removed : 2006-03-29T08:00Z Temperature Stabiliz. : Additional Information : Additional Number LE 5800 on the type level 3.3 Receiver Type : JPS LEGACY Satellite System : GPS+GLO Serial Number : AF2ETZ85Y4G Firmware Version : E_GGD_2/2.5p1 Elevation Cutoff Setting : 5 deg Date Installed : 2006-03-29T08:00Z Date Removed : 2007-05-08T11:00Z Temperature Stabiliz. : Additional Information : Additional Number LE 5800 on the type level 3.4 Receiver Type : JPS LEGACY Satellite System : GPS+GLO Serial Number : AF2ETZ85Y4G Firmware Version : 2.6.0 APR,18,2007 Elevation Cutoff Setting : 0 deg Date Installed : 2007-05-08T11:00Z Date Removed : 2008-01-25T11:45Z Temperature Stabiliz. : Additional Information : Additional Number LE 5800 on the type level 3.5 Receiver Type : JPS LEGACY Satellite System : GPS+GLO Serial Number : AF2ETZ85Y4G Firmware Version : 2.6.1 JAN,10,2008 Elevation Cutoff Setting : 0 deg Date Installed : 2008-01-25T11:45Z Date Removed : 2015-07-07T08:00Z Temperature Stabiliz. : Additional Information : Additional Number LE 5800 on the type level 3.6 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL+BDS+SBAS Serial Number : 01591 Firmware Version : 3.5.9 APR,21,2015 Elevation Cutoff Setting : 0 deg Date Installed : 2015-07-07T09:00Z Date Removed : 2016-07-10T12:00Z Temperature Stabiliz. : Additional Information : Bord ID : 013NBW6VQSP3X11CYHBZ506632 3.7 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL+BDS+SBAS Serial Number : 01591 Firmware Version : 3.6.6 APR,27,2016 Elevation Cutoff Setting : 0 deg Date Installed : 2016-07-10T12:00Z Date Removed : 2017-03-28T08:00Z Temperature Stabiliz. : none Additional Information : Bord ID : 013NBW6VQSP3X11CYHBZ506632 3.8 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL+BDS+SBAS Serial Number : 01591 Firmware Version : 3.7.0 MAR,03,2017 Elevation Cutoff Setting : 0 deg Date Installed : 2017-03-28T08:00Z Date Removed : 2017-06-07T09:00Z Temperature Stabiliz. : none Additional Information : Bord ID : 013NBW6VQSP3X11CYHBZ506632 3.9 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL+BDS+SBAS Serial Number : 01591 Firmware Version : 3.7.1 APR,04,2017 Elevation Cutoff Setting : 0 deg Date Installed : 2017-06-07T09:00Z Date Removed : 2019-01-30T09:10Z Temperature Stabiliz. : none Additional Information : Bord ID : 013NBW6VQSP3X11CYHBZ506632 3.10 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL+BDS+SBAS Serial Number : 01591 Firmware Version : 3.7.5P1 JAN,23,2019 Elevation Cutoff Setting : 0 deg Date Installed : 2019-01-30T09:10Z Date Removed : 2019-05-13T11:00Z Temperature Stabiliz. : none Additional Information : Bord ID: 013NBW6VQSP3X11CYHBZ506632 3.11 Receiver Type : JAVAD TRE_3 DELTA Satellite System : GPS+GLO+GAL+BDS+SBAS Serial Number : 02890 Firmware Version : 3.7.6 APR,08,2019 Elevation Cutoff Setting : 0 deg Date Installed : 2019-05-13T11:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : none Additional Information : Bord ID: 198GILL1QGDGX0QDSPVJA2QGHS 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TPSCR3_GGD CONE Serial Number : 217 0111 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.1750 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : CONE Radome Serial Number : Antenna Cable Type : Aircom plus Antenna Cable Length : 50 m Date Installed : 2003-02-11T12:00Z Date Removed : 2003-10-22T08:00Z Additional Information : 4.2 Antenna Type : TPSCR3_GGD CONE Serial Number : 217 0159 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.1750 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : CONE Radome Serial Number : Antenna Cable Type : Aircom plus Antenna Cable Length : 50 m Date Installed : 2003-10-22T08:00Z Date Removed : 2004-08-12T08:00Z Additional Information : absolute Individuel Calibration 4.3 Antenna Type : TPSCR3_GGD CONE Serial Number : 217 0159 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0686 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : CONE Radome Serial Number : Antenna Cable Type : Aircom plus Antenna Cable Length : 50 m Date Installed : 2004-08-12T08:00Z Date Removed : 2005-03-01T05:00Z Additional Information : absolute Individuel Calibration 4.4 Antenna Type : TPSCR3_GGD CONE Serial Number : 217 0159 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0690 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : CONE Radome Serial Number : Antenna Cable Type : Aircom plus Antenna Cable Length : 50 m Date Installed : 2005-03-01T05:00Z Date Removed : 2010-09-15T09:00Z Additional Information : absolute Individuel Calibration 4.5 Antenna Type : LEIAR25.R3 LEIT Serial Number : 09050002 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0690 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : LEIT Radome Serial Number : Antenna Cable Type : RG214 Antenna Cable Length : 20 m Date Installed : 2010-09-15T09:30Z Date Removed : 2019-05-13T11:00Z Additional Information : Antenna calibrated absolute : by Geo++ GmbH, Garbsen 2010-07-01. 4.6 Antenna Type : LEIAR25.R4 LEIT Serial Number : 725559 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0690 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : LEIT Radome Serial Number : 0 Antenna Cable Type : RG214 Antenna Cable Length : 20 m Date Installed : 2019-05-13T11:00Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : Antenna calibrated absolute : by Geo++ GmbH, Garbsen 2013-01-17. : by Uni Bonn 2018-10-15 : by Senatsverwaltung Berlin 2019-05-02 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : Effective Dates : 2003-02-11/CCYY-MM-DD Notes : 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : HMP45A-P Manufacturer : Vaisala Oyi Serial Number : X2930002 Data Sampling Interval : 900 sec Accuracy (% rel h) : 1 Aspiration : CAPACITIVY THIN FILM POLYMER Height Diff to Ant : 0.13 m Calibration date : (CCYY-MM-DD) Effective Dates : 2003-02-11/2010-09-15 Notes : The humidity sensor is 0.13 m : below the antenna. 8.1.2 Humidity Sensor Model : HMP45A-P Manufacturer : Vaisala Oyi Serial Number : X4150004 Data Sampling Interval : 10 sec Accuracy (% rel h) : 1 Aspiration : CAPACITIVY THIN FILM POLYMER Height Diff to Ant : -0.15 m Calibration date : 2009-08-12 Effective Dates : 2010-09-15/2017-03-28 Notes : The humidity sensor is 0.15 m : below the antenna. 8.1.3 Humidity Sensor Model : HMP45A-P Manufacturer : Vaisala Oyi Serial Number : X4150003 Data Sampling Interval : 10 sec Accuracy (% rel h) : 1 Aspiration : CAPACITIVY THIN FILM POLYMER Height Diff to Ant : -0.15 m Calibration date : 2015-11-23 Effective Dates : 2017-03-28/CCYY-MM-DD Notes : The humidity sensor is 0.15 m : below the antenna. 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : PTU200 Manufacturer : Vaisala Oyi Serial Number : X2930002 Data Sampling Interval : 10 sec Accuracy : 0.1 hPa Height Diff to Ant : -3.8 m Calibration date : (CCYY-MM-DD) Effective Dates : 2003-02-11/CCYY-MM-DD Notes : The pressure Sensor is : 3.8 m below the antenna. 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : HMP45A-P Manufacturer : Vaisala Oyi Serial Number : X2930002 Data Sampling Interval : 10 sec Accuracy : 0.2 deg C Aspiration : RESISTIVE PLATINUM PROBE Height Diff to Ant : 0.13 m Calibration date : Effective Dates : 2003-02-11/2010-09-15 Notes : The temperature sensor is : 0.13 m below the antenna. 8.3.2 Temp. Sensor Model : HMP45A-P Manufacturer : Vaisala Oyi Serial Number : X4150004 Data Sampling Interval : 10 sec Accuracy : 0.2 deg C Aspiration : RESISTIVE PLATINUM PROBE Height Diff to Ant : -0.15 m Calibration date : 2009-08-12 Effective Dates : 2010-09-15/2017-03-28 Notes : The temperature sensor is : 0.15 m below the antenna. 8.3.3 Temp. Sensor Model : HMP45A-P Manufacturer : Vaisala Oyi Serial Number : X4150003 Data Sampling Interval : 10 sec Accuracy : 0.2 deg C Aspiration : RESISTIVE PLATINUM PROBE Height Diff to Ant : -0.15 m Calibration date : 2015-11-23 Effective Dates : 2017-03-28/CCYY-MM-DD Notes : The temperature sensor is : 0.15 m below the antenna. 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Bundesamt fuer Kartographie und Geodaesie : Department of Geodaesie Preferred Abbreviation : BKG Mailing Address : Richard-Strauss-Allee 11 : D-60598 Frankfurt a.M. : Germany Primary Contact Contact Name : BKG GNSS Data Center Telephone (primary) : +49 69 6333274 Telephone (secondary) : +49 69 63331 Fax : +49 69 6333425 E-mail : bkg-gdc@bkg.bund.de Secondary Contact Contact Name : GREF Operator Telephone (primary) : +49 341 5634333 Telephone (secondary) : Fax : +49 341 5634415 E-mail : dlz@bkg.bund.de Additional Information : 12. Responsible Agency (if different from 11.) Agency : Preferred Abbreviation : Mailing Address : Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : 13. More Information Primary Data Center : BKG Secondary Data Center : URL for More Information : www.bkg.bund.de Hardcopy on File Site Map : Site Diagram : Horizon Mask : Monument Description : Site Pictures : Additional Information : Antenna Graphics with Dimensions Topcon Positioning Systems: TPSCR3_GGD --------- / + \ <-- 0.104 L2 | + | <-- 0.081 L1 +--------------------------------------------------+ <-- 0.071 TCR | | | | | | | | +-----------------+-------------+------------------+ <-- 0.003 BCR +-----x-----+ <-- 0.0 BPA=ARP +---+ | | | | | | | | | | | | +---+ +---------+---+----------+ <-- -0.0686 <-- 0.326 --> LEIAR25.R3 +-------+ <-- 0.1995 / \ +---+-------------+---+ <-- 0.1606 TCR | | |---------------------------| |---------------------------------| |---------------------------------------| +---------------------------------------------+ | | | | +-+---------------------------------------------+-+ +-----------------+-------------+-----------------+ <-- 0.0320 BCR | | | | +------x------+ <-- 0.0000 BPA=ARP <-- 0.3802 --> ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center TCR: Top of Chokering BCR: Bottom of Chokering TGP: Top of Ground Plane BGP: Bottom of Ground Plane