TITZ Site Information Form International GPS Service 0. Form Prepared by (full name) : Robert Khachikyan Date Prepared : 2012-10-07 Report Type : UPDATE If Update: Previous Site Log : titz_20110309.log Modified/Added Sections : 4.1, 4.2 1. Site Identification of the GNSS Monument Site Name : Titz / Jackerath Four Character ID : TITZ Monument Inscription : IERS DOMES Number : 14278M001 CDP Number : Monument Description : STEEL Tripod Height of the Monument : Monument Foundation : CONCRETE BLOCKS Foundation Depth : (m) Marker Description : Thread - Rod Date Installed : 2001-09-27T10:00Z Geologic Characteristic : (BEDROCK/CLAY/CONGLOMERATE/GRAVEL/SAND/etc) Bedrock Type : Bedrock Condition : Fracture Spacing : none Fault zones nearby : (YES/NO/Name of the zone) Distance/activity : (multiple lines) Additional Information : Marker on a Steel Tripod : fixed on a concrete-platform. 2. Site Location Information City or Town : Titz State or Province : Nordrhein-Westfalen Country : Germany Tectonic Plate : Eurasean Plate Approximate Position (ITRF) X coordinate (m) : 3993780.705 Y coordinate (m) : 450206.585 Z coordinate (m) : 4936136.790 Latitude (N is +) : +510207.1 Longitude (E is +) : +0062553.9 Elevation (m,ellips.) : 155.6 Additional Information : (multiple lines) 3. GNSS Receiver Information 3.1 Receiver Type : JPS LEGACY Satellite System : GPS+GLO Serial Number : MT311605707 Firmware Version : EURO_3/2.1 JAN,03 Elevation Cutoff Setting : 5 deg Date Installed : 2001-09-27T10:00Z Date Removed : 2002-10-09T12:00Z Temperature Stabiliz. : none Additional Information : Additional number : LE 2813 on the type : level 3.2 Receiver Type : JPS LEGACY Satellite System : GPS+GLO Serial Number : MT311605707 Firmware Version : EURO_3/2.2p2 Elevation Cutoff Setting : 5 deg Date Installed : 2002-10-09T12:00Z Date Removed : 2003-01-14T10:00Z Temperature Stabiliz. : none Additional Information : Additional number : LE 2813 on the type : level 3.3 Receiver Type : JPS LEGACY Satellite System : GPS+GLO Serial Number : AGV7CCJP3B4 Firmware Version : E_GGD_2/2.2P2 Elevation Cutoff Setting : 5 deg Date Installed : 2003-01-14T10:00Z Date Removed : 2003-12-01T10:00Z Temperature Stabiliz. : none Additional Information : Additional number : LE 5791 on the type : level 3.4 Receiver Type : JPS LEGACY Satellite System : GPS+GLO Serial Number : AGV7CCJP3B4 Firmware Version : E_GGD_2/2.3P3 Elevation Cutoff Setting : 5 deg Date Installed : 2003-12-01T10:00Z Date Removed : 2006-11-22T12:00Z Temperature Stabiliz. : none Additional Information : Additional number : LE 5791 on the type : level 3.5 Receiver Type : JPS LEGACY Satellite System : GPS+GLO Serial Number : AGV7CCJP3B4 Firmware Version : E_GGD_2/2.5p2 Elevation Cutoff Setting : 5 deg Date Installed : 2006-11-22T12:00Z Date Removed : 2007-11-02T08:30Z Temperature Stabiliz. : none Additional Information : Additional number : LE 5791 on the type : level 3.6 Receiver Type : JPS LEGACY Satellite System : GPS+GLO Serial Number : AGV7CCJP3B4 Firmware Version : E_GGD_2/2.6.0 Elevation Cutoff Setting : 0 deg Date Installed : 2007-11-02T08:30Z Date Removed : 2008-01-25T08:00Z Temperature Stabiliz. : none Additional Information : Additional number : LE 5791 on the type : level 3.7 Receiver Type : JPS LEGACY Satellite System : GPS+GLO Serial Number : AGV7CCJP3B4 Firmware Version : 2.6.1 JAN,10,2008 Elevation Cutoff Setting : 0 deg Date Installed : 2008-01-25T08:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : none Additional Information : Additional number : LE 5791 on the type : level 4. GNSS Antenna Information 4.1 Antenna Type : JPSREGANT_SD_E2 NONE Serial Number : RA0291 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.020 Marker->ARP North Ecc(m) : Marker->ARP East Ecc(m) : Alignment from True N : Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : AIRCOM (R) PLUS Antenna Cable Length : 50 m Date Installed : 2001-09-27T10:00Z Date Removed : 2003-01-14T10:00Z Additional Information : : Antenna type listed in this section retro- : actively changed from JPSREGANT_SD_E to : JPSREGANT_SD_E2 starting with log file : titz_20121007.log. See IGSMAIL-6662 and : IGSMAIL-6663 for details. 4.2 Antenna Type : JPSREGANT_SD_E2 NONE Serial Number : RA0311 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.020 Marker->ARP North Ecc(m) : Marker->ARP East Ecc(m) : Alignment from True N : Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : AIRCOM (R) PLUS Antenna Cable Length : 50 m Date Installed : 2003-01-14T10:00Z Date Removed : 2008-02-20T15:30Z Additional Information : : Antenna type listed in this section retro- : actively changed from JPSREGANT_SD_E to : JPSREGANT_SD_E2 starting with log file : titz_20121007.log. See IGSMAIL-6662 and : IGSMAIL-6663 for details. 4.3 Antenna Type : TPSCR3_GGD CONE Serial Number : 217-0383 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.020 Marker->ARP North Ecc(m) : Marker->ARP East Ecc(m) : Alignment from True N : Antenna Radome Type : CONE Radome Serial Number : Antenna Cable Type : AIRCOM (R) PLUS Antenna Cable Length : 50 m Date Installed : 2008-02-20T15:30Z Date Removed : 2011-03-09T15:00Z Additional Information : 4.4 Antenna Type : LEIAR25.R4 LEIT Serial Number : 10231046 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 000.045 Marker->ARP North Ecc(m) : 000.000 Marker->ARP East Ecc(m) : 000.000 Alignment from True N : 0 Antenna Radome Type : LEIT Radome Serial Number : Antenna Cable Type : AIRCOM (R) PLUS Antenna Cable Length : 50 m Date Installed : 2011-03-09T17:00Z Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : Antenna calibrated absolute : by Geo++ GmbH, Garbsen 2010-09-29. 5. Surveyed Local Ties 5.1 Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : Effective Dates : Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : Status : Effective Dates : Notes : 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : HMP45A-P Manufacturer : Vaisala Oyi Serial Number : X2930003 Data Sampling Interval : 10 Accuracy (% rel h) : 1.0 Aspiration : CAPACITIVY THIN FILM POLYMER Height Diff to Ant : 0.5 m Calibration date : 2007-05-28 Effective Dates : 2008-02-20/CCYY-MM-DD Notes : Humidity Sensor is 0.5 m : above the antenna 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : PTU200 Manufacturer : Vaisala Oyi Serial Number : W511011 Data Sampling Interval : 10 Accuracy : 0.1 Height Diff to Ant : 0.5 m Calibration date : 2001-12-17 Effective Dates : 2003-01-14/CCYY-MM-DD Notes : Pressure Sensor is : 0.5 m above the antenna 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : HMP45A-P Manufacturer : Vaisala Oyi Serial Number : X2930003 Data Sampling Interval : 10 Accuracy : 0.2 Aspiration : RESISTIVE PLATINUM PROBE Height Diff to Ant : 0.5 m Calibration date : 2007-05-28 Effective Dates : 2008-02-20/CCYY-MM-DD Notes : Humidity Sensor is 0.5 m : above the antenna 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.1 Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.1 Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.1 Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.1 Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.1 Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.1 Date : (CCYY-MM-DDThh:mmZ) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Bundesamt fuer Kartographie und Geodaesie Preferred Abbreviation : BKG Mailing Address : Bundesamt fuer Kartographie und Geodaesie : Department of Geodaesie : Richard Strauss Allee 11 : D 60598 Frankfurt / M. : Germany Primary Contact Contact Name : Peter Franke Telephone (primary) : (0049)-69-6333-279 Telephone (secondary) : (0049)-69-6333-1 Fax : (0049)-69-6333-425 E-mail : peter.franke@bkg.bund.de Secondary Contact Contact Name : see 12. Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : Bundesamt fuer Kartographie und Geodaesie Preferred Abbreviation : BKG Mailing Address : Bundesamt fuer Kartographie und Geodaesie : Branch Leipzig : Karl Rothe Str. 10-14 : D 04105 Leipzig : Germany Primary Contact Contact Name : Mathias Groeschel Telephone (primary) : (0049)-341-5634-432 Telephone (secondary) : (0049)-341-5634-0 Fax : (0049)-341-5634-1921 E-mail : matthias.groeschel@bkg.bund.de Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : Bundesamt fuer Kartographie und Geodaesie : Abt. Geodaesie : Referat G2 : Richard Strauss Allee 11 : D 60598 Frankfurt / M. : Germany : http://www.bkg.bund.de Secondary Data Center : CDDIS URL for More Information : http://igs.bkg.bund.de Hardcopy on File Site Map : (Y or URL) Site Diagram : (Y or URL) Horizon Mask : (Y or URL) Monument Description : (Y or URL) Site Pictures : (Y or URL) Additional Information : (multiple lines) Antenna Graphics with Dimensions REGANT - SD +-------------------------+ <-- Plastic Housing for / ------------------- \ Antenna/Choke Ring / / \ \ +---------+ | + | +---------+ <-- 0.1060 L1 | +-------------------------------------------------+ | <-- TCR / | | \ | | | | | | | | | | | | \+-----------------------------------------------------+/ |+-----------------------------------------------------+| <-- BCR \______________ | | ______________/ \ | | / \+---------x---------+/ <-- 0.0000 ARP=BPA TPSCR3_GGD --------- / + \ <-- 0.104 = L2 | + | <-- 0.081 = L1 +--------------------------------------------------+ <-- 0.071 = TCR | | | | | | | | +-----------------+-------------+------------------+ <-- 0.003 = BCR +-----x-----+ <-- 0.000 BPA=ARP <-- 0.326 --> LEIAR25.R4 +-------+ <-- 0.1995 / \ +---+-------------+---+ <-- 0.1606 TCR | | |---------------------------| |---------------------------------| |---------------------------------------| +---------------------------------------------+ | | | | +-+---------------------------------------------+-+ +-----------------+-------------+-----------------+ <-- 0.0320 BCR | | | | +------x------+ <-- 0.0000 BPA=ARP <-- 0.3802 --> ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center TCR: Top of Chokering BCR: Bottom of Chokering TGP: Top of Ground Plane BGP: Bottom of Ground Plane TPA: Top of Preamplifier BPA: Bottom of Preamplifier TOP: Top of Pole BOP: Bottom of Pole