TIT200DEU Site Information Form (site log) International GNSS Service See Instructions at: ftp://igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : GREF Operator Date Prepared : 2019-12-03 Report Type : UPDATE If Update: Previous Site Log : tit2_20191114.log Modified/Added Sections : 3.5, 3.6, 8.5.4, 8.5.2, 8.5.1, 8.5.3, 11 1. Site Identification of the GNSS Monument Site Name : Titz / Jackerath Four Character ID : TIT2 Monument Inscription : IERS DOMES Number : 14278M002 CDP Number : Monument Description : Steelpipe with heat protection Height of the Monument : 2.2 m Monument Foundation : 2014 Foundation Depth : 12 m Marker Description : SURVEY MARKER BOLT ON THE PILLAR Date Installed : 2014-12-10T00:00Z Geologic Characteristic : Bedrock Type : Bedrock Condition : Fracture Spacing : Fault zones nearby : Distance/activity : Additional Information : Survey Marker Bolt on a pillar. : Antenna mounted with a special screw : adapter on a rivet thread of a circular : tube of steel filled with concrete, : 14.5 m length : placed on the ground at Goelogischer Dienst : Nordrhein-Westfalen : In addition and parallel a JPS LEGACY GPS+GLO : Receiver, Four character ID TITZ, : DOMES No. 14278M001. : Further informations and effective : dates see section 7. 2. Site Location Information City or Town : Titz State or Province : Nordrhein-Westfalen Country : Germany Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : 3993787.260 Y coordinate (m) : 450203.890 Z coordinate (m) : 4936131.690 Latitude (N is +) : +510206.84 Longitude (E is +) : +0062553.68 Elevation (m,ellips.) : 156.1 Additional Information : 3. GNSS Receiver Information 3.1 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL+SBAS Serial Number : 01690 Firmware Version : 3.6.0 JUN,23,2014 Elevation Cutoff Setting : 0 deg Date Installed : 2014-12-11T09:00Z Date Removed : 2016-08-09T13:30Z Temperature Stabiliz. : none Additional Information : Bord ID : 02RRVTI255XJX2EJ3XLQDJMTBB 3.2 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL+BDS+SBAS Serial Number : 01690 Firmware Version : 3.6.6 APR,27,2016 Elevation Cutoff Setting : 0 deg Date Installed : 2016-08-09T13:30Z Date Removed : 2017-06-06T10:30Z Temperature Stabiliz. : none Additional Information : Bord ID : 02RRVTI255XJX2EJ3XLQDJMTBB 3.3 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL+BDS+SBAS Serial Number : 01690 Firmware Version : 3.7.1 APR,04,2017 Elevation Cutoff Setting : 0 deg Date Installed : 2017-06-06T10:30Z Date Removed : 2018-01-10T09:00Z Temperature Stabiliz. : none Additional Information : Bord ID : 02RRVTI255XJX2EJ3XLQDJMTBB 3.4 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL+BDS+SBAS Serial Number : 01690 Firmware Version : 3.7.2 Aug,31,2017 Elevation Cutoff Setting : 0 deg Date Installed : 2018-01-10T09:00Z Date Removed : 2018-04-11T10:00Z Temperature Stabiliz. : none Additional Information : Bord ID : 02RRVTI255XJX2EJ3XLQDJMTBB 3.5 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL+BDS+SBAS Serial Number : 01690 Firmware Version : 3.7.3 FEB,02,2018 Elevation Cutoff Setting : 0 deg Date Installed : 2018-04-11T10:00Z Date Removed : 2019-12-03T09:20Z Temperature Stabiliz. : none Additional Information : Bord ID : 02RRVTI255XJX2EJ3XLQDJMTBB 3.6 Receiver Type : JAVAD TRE_3 DELTA Satellite System : GPS+GLO+GAL+BDS+SBAS Serial Number : 02909 Firmware Version : 3.7.7 OCT,08,2019 Elevation Cutoff Setting : 0 deg Date Installed : 2019-12-03T09:30Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : none Additional Information : Bord ID : 1982NQ5YA4OC10QDSPVJA2QGHS 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : LEIAR25.R4 LEIT Serial Number : 725557 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0450 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : LEIT Radome Serial Number : Antenna Cable Type : ECOFLEX 10 Antenna Cable Length : 41 m Date Installed : 2014-12-11T09:00Z Date Removed : 2018-04-11T07:50Z Additional Information : Antenna calibrated absolute : by Geo++ GmbH, Garbsen 2013-01-15. 4.2 Antenna Type : LEIAR25.R4 LEIT Serial Number : 726856 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0450 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : LEIT Radome Serial Number : Antenna Cable Type : ECOFLEX 10 Antenna Cable Length : 41 m Date Installed : 2018-04-11T11:10Z Date Removed : 2019-11-13T10:15Z Additional Information : Antenna calibrated absolute : by Uni Bonn, Institut für Geodaesie und : Geoinformation : Antennenmesskammer 2018-01-31 4.3 Antenna Type : LEIAR25.R4 LEIT Serial Number : 725551 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0450 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : LEIT Radome Serial Number : Antenna Cable Type : Ecoflex 10 Antenna Cable Length : 41 m Date Installed : 2019-11-13T10:15Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : Antenna individual calibrated absolute : by UNIBN 2019-09-23 : by Senat Berlin 2019-08-21 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : Effective Dates : 2005-07-01/CCYY-MM-DD Notes : 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : JPS LEGACY GPS+GLONASS TITZ Status : PERMANENT Effective Dates : 2001-09-27/CCYY-MM-DD Notes : 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : WXTPTU Manufacturer : Vaisala Serial Number : J2420011 Data Sampling Interval : 10 sec Accuracy (% rel h) : 3 Aspiration : NATURAL Height Diff to Ant : 0.7 m Calibration date : 2013-06-14 Effective Dates : 2018-04-11/CCYY-MM-DD Notes : Vaisala WXT520 SN: J2440010 : Humidity Sensor is 0.7 m above the antenna : capacitive thin film polymer HUMICAP 180 sensor 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : WXTPTU Manufacturer : Vaisala Serial Number : J2420011 Data Sampling Interval : 10 sec Accuracy : 1 hPa Height Diff to Ant : 0.7 m Calibration date : 2013-01-10 Effective Dates : 2018-04-11/CCYY-MM-DD Notes : Vaisala WXT520 SN: J2440010 : Pressure Sensor is 0.7 m above the antenna : capacitive silicon BAROCAP sensor 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : WXTPTU Manufacturer : Vaisala Serial Number : J2420011 Data Sampling Interval : 10 sec Accuracy : 0.3 deg C Aspiration : NATURAL Height Diff to Ant : 0.7 m Calibration date : 2013-01-10 Effective Dates : 2018-04-11/CCYY-MM-DD Notes : Vaisala WXT520 SN: J2440010 : Temperature Sensor is 0.7 m above the antenna : capacitive ceramic THERMOCAP sensor 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.1 Other Instrumentation : Wind Azimut : Wind Sensor Model WXT520 (heated) : Manufacturer Vaisala : Serial Number J2440010 : Data Sampling Interval 10 sec : Accuracy 3 deg : Height Diff to Ant +0.7 m : Test date 2013-01-10 : Effective Dates 2018-04-11/CCYY-MM-DD : Notes Wind Sensor is 0.7 m above the antenna : Notes ultrasonic WINDCAP sensor 8.5.2 Other Instrumentation : Wind Speed : Wind Sensor Model WXT520 (heated) : Manufacturer Vaisala : Serial Number J2440010 : Data Sampling Interval 10 sec : Accuracy : measurement values 0..35 m/s 0.3 m/s or 3% : measurement values 36..60 m/s 5% : Height Diff to Ant +0.7 m : Test date 2013-01-10 : Effective Dates 2018-04-11/CCYY-MM-DD : Notes Wind Sensor is 0.7 m above the antenna : Notes ultrasonic WINDCAP sensor 8.5.3 Other Instrumentation : Rain Increment : Rain Sensor Model WXT520 (heated) : Manufacturer Vaisala : Serial Number J2440010 : Data Sampling Interval 10 sec : Accuracy 5 % : Height Diff to Ant +0.7 m : Test date 2013-01-10 : Effective Dates 2018-04-11/CCYY-MM-DD : Notes Rain Sensor is 0.7 m above the antenna : Notes piezoelectrical RAINCAP sensor 8.5.4 Other Instrumentation : Hail Indicator : Hail Sensor Model WXT520 (heated) : Manufacturer Vaisala : Serial Number J2440010 : Data Sampling Interval 10 sec : Accuracy 5 % : Height Diff to Ant +0.7 m : Test date 2013-01-10 : Effective Dates 2018-04-11/CCYY-MM-DD : Notes Hail Sensor is 0.7 m above the antenna : Notes piezoelectrical RAINCAP sensor 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Bundesamt fuer Kartographie und Geodaesie : Department of Geodaesie Preferred Abbreviation : BKG Mailing Address : Richard-Strauss-Allee 11 : D-60598 Frankfurt a.M. : Germany Primary Contact Contact Name : BKG GNSS Data Center Telephone (primary) : +49 69 6333274 Telephone (secondary) : +49 69 63331 Fax : +49 69 6333425 E-mail : bkg-gdc@bkg.bund.de Secondary Contact Contact Name : GREF Operator Telephone (primary) : +49 341 5634333 Telephone (secondary) : Fax : +49 341 5634415 E-mail : dlz@bkg.bund.de Additional Information : 12. Responsible Agency (if different from 11.) Agency : Preferred Abbreviation : Mailing Address : Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : 13. More Information Primary Data Center : BKG Secondary Data Center : CDDIS URL for More Information : www.bkg.bund.de Hardcopy on File Site Map : Site Diagram : Horizon Mask : Monument Description : Site Pictures : Y Additional Information : Data center Bundesamt fuer : Kartographie und : Geodaesie : Department of Geodaesie : Referat G2 : Richard Strauss Allee 11 : D 60598 Frankfurt / M. : Germany : http://igs.bkg.bund.de Antenna Graphics with Dimensions LEIAR25.R3/LEIAR25.R4 +-------+ <-- 0.1995 / \ +---+-------------+---+ <-- 0.1606 TCR | | |---------------------------| |---------------------------------| |---------------------------------------| +---------------------------------------------+ | | | | +-+---------------------------------------------+-+ +-----------------+-------------+-----------------+ <-- 0.0320 BCR | | | | +------x------+ <-- 0.0000 BPA=ARP <-- 0.3802 --> ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center TCR: Top of Chokering BCR: Bottom of Chokering TGP: Top of Ground Plane BGP: Bottom of Ground Plane TPA: Top of Preamplifier BPA: Bottom of Preamplifier TOP: Top of Pole