SULP Site Information Form (site log) International GNSS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Stepan Savchuk Date Prepared : 2015-03-03 Report Type : UPDATE If Update: Previous Site Log : sulp_20141209.log Modified/Added Sections : 3.3, 3.4, 3.5 1. Site Identification of the GNSS Monument Site Name : Lviv Polytechnic Four Character ID : SULP Monument Inscription : IERS DOMES Number : 12366M001 CDP Number : Monument Description : PILLAR ABOVE THE ROOF Height of the Monument : 25 m Monument Foundation : ROCK BASE Foundation Depth : 5 m Marker Description : CHISELLED CROSS Date Installed : 2001-06-01T00:00Z Geologic Characteristic : BEDROCK Bedrock Type : METAMORPHIC Bedrock Condition : JOINTED Fracture Spacing : 51-200 cm Fault zones nearby : Distance/activity : Additional Information : Fundamental astronomical monument, which was : constructed and built on rock base in 1870 : inside the main building of the University : in such a manner to have no any contact with : the building itself. 2. Site Location Information City or Town : Lviv State or Province : Lviv Country : Ukraine Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : 3765296.991 Y coordinate (m) : 1677559.204 Z coordinate (m) : 4851297.409 Latitude (N is +) : +495008.11 Longitude (E is +) : +0240052.15 Elevation (m,ellips.) : 370.5 Additional Information : 3. GNSS Receiver Information 3.1 Receiver Type : TRIMBLE 4700 Satellite System : GPS Serial Number : 20236698 Firmware Version : 1.30 Elevation Cutoff Setting : 5 deg Date Installed : 2001-06-10T00:00Z Date Removed : 2010-07-28T17:00Z Temperature Stabiliz. : 21.0 +/- 1.0 Additional Information : 3.2 Receiver Type : TRIMBLE 4700 Satellite System : GPS Serial Number : 20181663 Firmware Version : Nav 1.41 / Boot 1 Elevation Cutoff Setting : 5 deg Date Installed : 2010-11-24T00:00Z Date Removed : 2013-03-30T09:00Z Temperature Stabiliz. : 21.0 +/- 1.0 Additional Information : 3.3 Receiver Type : TPS NET-G3A Satellite System : GPS+GLO+SBAS Serial Number : 02215 Firmware Version : 4.0 Aug,03,2012 Elevation Cutoff Setting : 5 deg Date Installed : 2013-04-05T13:23Z Date Removed : 2014-11-30T16:40Z Temperature Stabiliz. : 21.0 +/- 1.0 Additional Information : 3.4 Receiver Type : TPS NET-G3A Satellite System : GPS+GLO+GAL+SBAS Serial Number : 02215 Firmware Version : 4.1 May,31,2013 Elevation Cutoff Setting : 5 deg Date Installed : 2014-11-30T16:55Z Date Removed : 2015-03-03T13:10Z Temperature Stabiliz. : 21.0 +/- 1.0 Additional Information : 3.5 Receiver Type : TPS NET-G3A Satellite System : GPS+GLO+SBAS Serial Number : 02215 Firmware Version : 4.1 May,31,2013 Elevation Cutoff Setting : 5 deg Date Installed : 2015-03-03T13:11Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : 20.0 +/- 1.0 Additional Information : 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TRM33429.20+GP NONE Serial Number : 34547 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 4.7340 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Trimble Antenna Cable Length : 30 m Date Installed : 2001-06-10T00:00Z Date Removed : 2001-10-13T09:37Z Additional Information : Antenna TRM33429.20+GP will be : changed to new antenna Zephyr 4.2 Antenna Type : TRM41249.00 NONE Serial Number : 423 Antenna Reference Point : BAM Marker->ARP Up Ecc. (m) : 4.7290 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Trimble Antenna Cable Length : 30 m Date Installed : 2001-10-13T09:38Z Date Removed : 2013-03-30T09:00Z Additional Information : New antenna Zephyr now installed 4.3 Antenna Type : TPSCR.G5 TPSH Serial Number : 11138 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 4.7290 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : TPSH Radome Serial Number : Antenna Cable Type : ASHTECH PN 100914 REV A 08MQO 9835 Antenna Cable Length : 30 m Date Installed : 2013-03-30T11:16Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : Antenna manufacture label: : TOPCON : P/N: 01-070801-01 : S/N: 762-11138 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : Effective Dates : 2001-06-01/CCYY-MM-DD Notes : 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Lviv Polytechnic National University Preferred Abbreviation : NULP Mailing Address : 12, S.Bandera Str.,Lviv, 79013, UKRAINE Primary Contact Contact Name : Stepan Savchuk Telephone (primary) : +380-32-258-21-81 Telephone (secondary) : Fax : +380-32-258-26-98 E-mail : ssavchuk@polynet.lviv.ua Secondary Contact Contact Name : Korneliy Tretjak Telephone (primary) : +380-032-258-22-34 Telephone (secondary) : Fax : E-mail : kornel@polynet.lviv.ua Additional Information : 12. Responsible Agency (if different from 11.) Agency : Preferred Abbreviation : Mailing Address : Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : 13. More Information Primary Data Center : BKG Secondary Data Center : OLG URL for More Information : Hardcopy on File Site Map : Site Diagram : Horizon Mask : Monument Description : Site Pictures : Additional Information : Antenna Graphics with Dimensions TRM41249.00 NONE -------------------+-------------------- <-- 0.0714 L1 / + + + <-- 0.0682 L2 / ---------------------------------------- | | | | +----x----+ <-- 0.0 ARP=TOP <-- 0.33962 --> EDGE ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center TPSCR.G5 +-------+ / \ | | +-----------------+-------------+-----------------+ <-- 0.0885 TCR | | | | | | | | +-+-------------------------------------------------+-+ +-------------------+-------------+-------------------+ <-- 0.0345 BCR | | | | +------x------+ <-- 0.0000 BPA=ARP <-- 0.2380 --> <-- 0.3800 -->