PTAG Site Information Form (site log) International GNSS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Charisma Victoria D. Cayapan Date Prepared : 2016-03-14 Report Type : UPDATE If Update: Previous Site Log : ptag_20120206.log Modified/Added Sections : 1 (Monument Description, Geologic : Characteristic), : 2 (Tectonic Plate, Approximate Position), : 3.1-3.6, 5.1, 5.2, 7.2, 7.3, 8.1-8.3, 9.3.1 : 11 (Primary and Secondary Contacts) 1. Site Identification of the GNSS Monument Site Name : NAMRIA Taguig Active Geodetic Station Four Character ID : PTAG Monument Inscription : IERS DOMES Number : 22006M005 CDP Number : Monument Description : ROOF BASED - PILLAR Height of the Monument : 1.635 (m) from survey marker to ARP m Monument Foundation : Bolted to one of the building's vertical colum Foundation Depth : Marker Description : NONE Date Installed : 2008-09-23T00:00Z Geologic Characteristic : Bedrock Type : Bedrock Condition : Fracture Spacing : Fault zones nearby : East Valley Fault Line Distance/activity : Additional Information : 2. Site Location Information City or Town : Taguig City State or Province : Metro Manila Country : Philippines Tectonic Plate : PHILIPPINE Approximate Position (ITRF) X coordinate (m) : -3184318.745 Y coordinate (m) : 5291065.489 Z coordinate (m) : 1590418.235 Latitude (N is +) : +143207.59009 Longitude (E is +) : +1210226.75542 Elevation (m,ellips.) : 86.647 Additional Information : Ellipsoidal height measured from BPA : Position from AUSPOS 3. GNSS Receiver Information 3.1 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355445 Firmware Version : 5.60/3.014 Elevation Cutoff Setting : 0 deg Date Installed : 2008-09-23T00:00Z Date Removed : 2012-01-31T06:44Z Temperature Stabiliz. : NONE Additional Information : 3.2 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355445 Firmware Version : 5.60/3.019 Elevation Cutoff Setting : 0 deg Date Installed : 2012-01-31T07:14Z Date Removed : 2012-02-01T06:09Z Temperature Stabiliz. : NONE Additional Information : Measurement engine upgraded from 3.014 : to 3.019 on 2012-01-31 3.3 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355445 Firmware Version : 8.50/3.019 Elevation Cutoff Setting : 0 deg Date Installed : 2012-02-01T06:19Z Date Removed : 2014-07-22T06:03Z Temperature Stabiliz. : NONE Additional Information : Firmware upgraded from 5.60 to 8.50 on : 2012-02-01 3.4 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355445 Firmware Version : 8.50/3.055 Elevation Cutoff Setting : 0 deg Date Installed : 2014-07-22T08:45Z Date Removed : 2016-03-07T07:43Z Temperature Stabiliz. : NONE Additional Information : Measurement engine upgraded from 3.019 to : 3.055 on 2014-07-22 3.5 Receiver Type : LEICA GR25 Satellite System : GPS+GLO Serial Number : 1831080 Firmware Version : 3.03/6.214 Elevation Cutoff Setting : 0 deg Date Installed : 2016-03-08T06:06Z Date Removed : 2016-03-14T01:51Z Temperature Stabiliz. : NONE Additional Information : Replaced LEICA GRX1200GGPRO with : LEICA GR25 receiver 3.6 Receiver Type : LEICA GR25 Satellite System : GPS+GLO Serial Number : 1831080 Firmware Version : 3.22/6.521 Elevation Cutoff Setting : 0 deg Date Installed : 2016-03-14T02:02Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : NONE Additional Information : Firmware upgraded from 3.03/6.214 to : 3.22/6.521 on 2016-03-14 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : LEIAT504GG LEIS Serial Number : 200479 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : -01 deg Antenna Radome Type : LEIS Radome Serial Number : Antenna Cable Type : Antenna Cable Length : Date Installed : 2008-09-23T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : Antenna aligned to magnetic north, magnetic : declination was computed to be -01 deg 24 min 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.1 Tied Marker Name : DORIS antenna ref. pt. (MANB) Tied Marker Usage : DORIS Tied Marker CDP Number : Tied Marker DOMES Number : 22006S002 Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : dy (m) : dz (m) : Accuracy (mm) : Survey method : TRIANGULATION Date Measured : 2014-12-06T00:00Z Additional Information : high geodetic surveying 5.2 Tied Marker Name : PTGG Tied Marker Usage : Tied Marker CDP Number : Tied Marker DOMES Number : 22006M006 Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : dy (m) : dz (m) : Accuracy (mm) : Survey method : TRIANGULATION Date Measured : 2014-12-06T00:00Z Additional Information : high geodetic surveying 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : Effective Dates : 2008-09-23/CCYY-MM-DD Notes : 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : DORIS Status : PERMANENT Effective Dates : 1991-04-01/CCYY-MM-DD Notes : 7.2 Instrumentation Type : GPS/GLONASS/QZSS Status : PERMANENT Effective Dates : 2013-05-16/CCYY-MM-DD Notes : 7.3 Instrumentation Type : GPS/GLONASS/GALILEO/BEIDOU/QZSS Status : PERMANENT Effective Dates : 2014-12-05/CCYY-MM-DD Notes : 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : Met 4 Manufacturer : Paroscientific, Inc. Serial Number : DQ105661 Data Sampling Interval : 20 sec Accuracy (% rel h) : 2% @ 25degC Aspiration : UNASPIRATED Height Diff to Ant : -0.01 m Calibration date : (CCYY-MM-DD) Effective Dates : 2008-06-16/CCYY-MM-DD Notes : Height diff from top of sensor to bottom : of choke ring 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : Met 4 Manufacturer : Paroscientific, Inc. Serial Number : DQ105661 Data Sampling Interval : 20 sec Accuracy : Better than 0.08 hPa Height Diff to Ant : -0.01 m Calibration date : (CCYY-MM-DD) Effective Dates : 2008-06-16/CCYY-MM-DD Notes : Height diff from top of sensor to bottom : of choke ring 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : Met 4 Manufacturer : Paroscientific, Inc. Serial Number : DQ105661 Data Sampling Interval : 20 sec Accuracy : better than 0.5 deg C Aspiration : UNASPIRATED Height Diff to Ant : -0.01 m Calibration date : Effective Dates : 2008-06-16/CCYY-MM-DD Notes : Height diff from top of sensor to bottom : of choke ring 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.1 Radio Interferences : CELL PHONE ANTENNA Observed Degradations : NO DATA Effective Dates : 2005-01-01/CCYY-MM-DD Additional Information : 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.1 Multipath Sources : Metal Roof Effective Dates : 1988-01-01/CCYY-MM-DD Additional Information : 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.1 Signal Obstructions : BUILDING Effective Dates : 2015/CCYY-MM-DD Additional Information : 12 story condominium building newly : constructed on western corner of station 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : National Mapping and Resource Information Authority Preferred Abbreviation : NAMRIA Mailing Address : NAMRIA, Lawton Avenue, Fort Andres Bonifacio, : Taguig City, Philippines Primary Contact Contact Name : Charisma Victoria D. Cayapan Telephone (primary) : (+632)8104831 local 601 Telephone (secondary) : (+632)8842849 Fax : (+632)8842844 E-mail : pagenet@namria.gov.ph Secondary Contact Contact Name : Hennesey R. Marohom Telephone (primary) : (+632)8104831 local 620 Telephone (secondary) : (+632)8842849 Fax : E-mail : pagenet@namria.gov.ph Additional Information : 12. Responsible Agency (if different from 11.) Agency : Preferred Abbreviation : Mailing Address : Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : 13. More Information Primary Data Center : IGN Secondary Data Center : GA URL for More Information : http://pagenet.namria.gov.ph Hardcopy on File Site Map : http://pagenet.namria.gov.ph Site Diagram : Horizon Mask : Monument Description : Site Pictures : Additional Information : Antenna Graphics with Dimensions LEIAT504GG +-------+ <-- 0.1393 / \ | | +-----------------+-------------+-----------------+ <-- 0.1012 TCR | | | | | | | | +-+-------------------------------------------------+-+ <-- 0.0378 +-------------------+-------------+-------------------+ <-- 0.0345 BCR | | | | +------x------+ <-- 0.0000 BPA=ARP <-- 0.3794 --> ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center TCR: Top of Chokering BCR: Bottom of Chokering TGP: Top of Ground Plane BGP: Bottom of Ground Plane TPA: Top of Preamplifier BPA: Bottom of Preamplifier TOP: Top of Pole