PPPC Site Information Form (site log) International GNSS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Hennesey Marohom Date Prepared : 2015-10-19 Report Type : UPDATE If Update: Previous Site Log : pppc_20140717.log Modified/Added Sections : (1, 2, 3.1, 4.1, 6.1, 8.1.1, 8.2.1, 8.3.1, : 8.5.1, 11, 12, 13) 1. Site Identification of the GNSS Monument Site Name : NAMRIA Puerto Princesa Active Geodetic Station Four Character ID : PPPC Monument Inscription : IERS DOMES Number : 22016M001 CDP Number : Monument Description : GROUND-BASED - PILLAR Height of the Monument : 1.4022 m Monument Foundation : Concrete Slab Foundation Depth : 2.25 m Marker Description : Date Installed : 2008-10-06T00:00Z Geologic Characteristic : Bedrock Type : Bedrock Condition : Fracture Spacing : Fault zones nearby : Distance/activity : Additional Information : 1.4022 Marker to ARP : 2. Site Location Information City or Town : Puerto Princesa City State or Province : Palawan Country : Philippines Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : -3022676.471 Y coordinate (m) : 5511839.403 Z coordinate (m) : 1075517.567 Latitude (N is +) : +094622.55710 Longitude (E is +) : +1184424.84146 Elevation (m,ellips.) : 66.543 Additional Information : Ellipsoidal height measured from BPA : Position from AUSPOS 3. GNSS Receiver Information 3.1 Receiver Type : LEICA GRX1200+GNSS Satellite System : GPS+GLO Serial Number : 495420 Firmware Version : 7.53/4.003 Elevation Cutoff Setting : 0 deg Date Installed : 2010-06-26T00:00Z Date Removed : 2012-10-19T00:00Z Temperature Stabiliz. : Additional Information : 3.2 Receiver Type : LEICA GRX1200+GNSS Satellite System : GPS+GLO Serial Number : 495420 Firmware Version : 8.51/6.111 Elevation Cutoff Setting : 0 deg Date Installed : 2012-10-19T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : Additional Information : Firmware upgrade - 7.53 to 8.51 on 2012-10-19 : Measurement enginer upgrade - 4.003 to 6.111 on : 2012-10-19 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : LEIAR25 LEIT Serial Number : 09300007 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 1.4022 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : LEIT Radome Serial Number : Antenna Cable Type : Antenna Cable Length : Date Installed : 2010-06-26T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : Effective Dates : 2010-06-26/CCYY-MM-DD Notes : 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : Met4 Manufacturer : Paroscientific, Inc. Serial Number : DQ117648 Data Sampling Interval : Accuracy (% rel h) : Aspiration : Height Diff to Ant : Calibration date : (CCYY-MM-DD) Effective Dates : 2008-10-01/CCYY-MM-DD Notes : 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Naval Forces West Preferred Abbreviation : Mailing Address : Naval Forces West, Puerto Princesa City, : Palawan Primary Contact Contact Name : Commo. Manuel Natalio Abinuman Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Cdr. Narciso Angelo PN Telephone (primary) : (+6348) 4341075 Telephone (secondary) : Fax : E-mail : Additional Information : 12. Responsible Agency (if different from 11.) Agency : National Mapping and Resource Information : Authority Preferred Abbreviation : NAMRIA Mailing Address : NAMRIA, Lawton Ave,Fort Bonifacio, : Taguig City, Philippines Primary Contact Contact Name : Charisma Victoria Cayapan Telephone (primary) : (+632) 8104831 local 615 Telephone (secondary) : (+632) 8842849 Fax : E-mail : Secondary Contact Contact Name : Hennesey R. Marohom Telephone (primary) : (+632) 8104831 local 615 Telephone (secondary) : (+632) 8842849 Fax : E-mail : Additional Information : 13. More Information Primary Data Center : PageNET Data and Control Center Secondary Data Center : GA URL for More Information : http://pagenet.namria.gov.ph Hardcopy on File Site Map : Site Diagram : Horizon Mask : Monument Description : Site Pictures : Additional Information : Antenna Graphics with Dimensions LEIAR25 +-------+ <-- 0.1995 / \ +- -+ |---+-------------+---| <-- 0.1456 TCR |---------------------------| |---------------------------------| |---------------------------------------| +---------------------------------------------+ | | | | +-+---------------------------------------------+-+ +-----------------+-------------+-----------------+ <-- 0.0320 BCR | | | | +------x------+ <-- 0.0000 BPA=ARP <-- 0.3802 -->