PADO Site Information Form International GPS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : PROF.ALESSANDRO CAPORALI Date Prepared : 2007-04-06 Report Type : UPDATE If Update: Previous Site Log : pado_20040517.log Modified/Added Sections : 3.5, 3.6 1. Site Identification of the GNSS Monument Site Name : UNIVERSITY OF PADOVA, CENTER FOR SPACE Four Character ID : PADO Monument Inscription : IERS DOMES Number : 12750S001 CDP Number : (A4) Monument Description : PLATE/STEEL Height of the Monument : 0.10 Monument Foundation : CONCRETE BLOCK ON ROOF OF LARGE BUILDING Foundation Depth : 5 Marker Description : TRIANGULAR STEEL PLATE WITH LEVEL SCREWS Date Installed : 2001-11-21T12:00Z Geologic Characteristic : CLAY/SAND Bedrock Type : SEDIMENTARY Bedrock Condition : (FRESH/JOINTED/WEATHERED) Fracture Spacing : (1-10 cm/10-50 cm/50-200 cm/over 200 cm) Fault zones nearby : NO Distance/activity : (multiple lines) Additional Information : (multiple lines) 2. Site Location Information City or Town : Padova State or Province : Country : Italy Tectonic Plate : ADRIATIC-AFRICAN PLATE Approximate Position (ITRF) X coordinate (m) : 4388882.182 Y coordinate (m) : 924567.324 Z coordinate (m) : 4519588.630 Latitude (N is +) : +452440.15 Longitude (E is +) : +0115345.82 Elevation (m,ellips.) : 00064.7 Additional Information : 3. GNSS Receiver Information 3.1 Receiver Type : TRIMBLE 4000SSI Satellite System : GPS Serial Number : 19459 Firmware Version : 7.25 / 3.07 Elevation Cutoff Setting : 10 Date Installed : 2001-11-21T13:00Z Date Removed : 2002-08-01T10:00Z Temperature Stabiliz. : none Additional Information : 3.2 Receiver Type : TRIMBLE 4700 Satellite System : GPS Serial Number : 63089 Firmware Version : 7.25 / 3.07 Elevation Cutoff Setting : 5 Date Installed : 2002-08-01T10:00Z Date Removed : 2002-10-30T10:00Z Temperature Stabiliz. : none Additional Information : 3.3 Receiver Type : TRIMBLE 4000SSI Satellite System : GPS Serial Number : 19459 Firmware Version : 7.32/3.08 Elevation Cutoff Setting : 5 Date Installed : 2002-11-04T10:00Z Date Removed : 2003-06-10T12:00Z Temperature Stabiliz. : none Additional Information : 3.4 Receiver Type : TRIMBLE 4000SSI Satellite System : GPS Serial Number : 19459 Firmware Version : 7.25 / 3.07 Elevation Cutoff Setting : 10 Date Installed : 2003-06-10T13:00Z Date Removed : 2003-06-17T13:00Z Temperature Stabiliz. : none Additional Information : 3.5 Receiver Type : TRIMBLE 4000SSI Satellite System : GPS Serial Number : 19459 Firmware Version : NAV 7.32 SIG 3.08 Elevation Cutoff Setting : 5 Date Installed : 2003-06-17T13:00Z Date Removed : 2007-04-05T13:00Z Temperature Stabiliz. : none Additional Information : 3.6 Receiver Type : TRIMBLE NETRS Satellite System : GPS Serial Number : 4607205216 Firmware Version : 1.1-3 28 Apr 2005 Elevation Cutoff Setting : 5 Date Installed : 2007-04-05T13:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : none Additional Information : 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS/GLONASS/GPS+GLONASS) Serial Number : (A5) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TRM29659.00 NONE Serial Number : 88300 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 000.0000 Marker->ARP North Ecc(m) : 000.0000 Marker->ARP East Ecc(m) : 000.0000 Alignment from True N : 0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : 30 Date Installed : 2001-11-21T13:00Z Date Removed : 2004-05-17T13:00Z Additional Information : 4.2 Antenna Type : TRM29659.00 NONE Serial Number : 88300 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 000.0000 Marker->ARP North Ecc(m) : 000.0000 Marker->ARP East Ecc(m) : 000.0000 Alignment from True N : 0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : 30 Date Installed : 2004-05-17T13:00Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.1 Tied Marker Name : UPAD Tied Marker Usage : GPS PERMANENT SITE OF IGS/EUREF Tied Marker CDP Number : Tied Marker DOMES Number : 12750M002 Differential Components from GNSS Marker to the tied monument dx (m) : -649.116 dy (m) : 1313.675 dz (m) : 332.294 Accuracy (mm) : < 5 mm Survey method : GPS CAMPAIGN Date Measured : 2001-11-15T10:00Z Additional Information : 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : dy (m) : dz (m) : Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : Effective Dates : 2001-11-21/CCYY-MM-DD Notes : (multiple lines) 6.x Standard Type : Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degredations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : UNIVERSITY OF PADOVA : DEPT. OF GEOLOGY, PALEONTOLOGY AND Preferred Abbreviation : UNIPD Mailing Address : VIA GIOTTO 1, 35137 PADOVA, ITALY Primary Contact Contact Name : PROF. A. CAPORALI Telephone (primary) : ++39-49-8272052 Telephone (secondary) : Fax : ++39-49-8272070 E-mail : alessandro.caporali@unipd.it Secondary Contact Contact Name : G. GIRARDI Telephone (primary) : ++39-49-8272055 Telephone (secondary) : Fax : E-mail : GIAMPAOLO.GIRARDI@UNIPD.IT Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : (multiple lines) Preferred Abbreviation : (A10) Mailing Address : (multiple lines) Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : BKGI Secondary Data Center : ASI URL for More Information : http://www.unipd.it/wwwgeol Hardcopy on File Site Map : (Y or URL) Site Diagram : X Horizon Mask : NO OBSTRUCTION ABOVE 0 DEGREES Monument Description : X Site Pictures : X Additional Information : (multiple lines) Antenna Graphics with Dimensions TRM29659.00 Trimble L1/L2 Dorne Margolin element with chokerings Model 29659.00 +-------+ / + \ <-- 0.1280 L2 | + | <-- 0.1100 L1 +--------------------------------------------------+ <-- 0.1020 TCR | | | | | | | | +-+--------------------------------------------------+-+ <-- 0.0380 +-------------------+-------------+--------------------+ <-- 0.0350 BCR | | | | +------x------+ <-- 0.0000 BPA=ARP <-- 0.3810 --> ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center TCR: Top of Chokering BCR: Bottom of Chokering BPA: Bottom of Preamplifier