NCKU Site Information Form (site log) International GNSS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Jyh-Ching Juang (NCKU) Date Prepared : 2014-07-25 Report Type : Update If Update: Previous Site Log : NCKU_20140716.log Modified/Added Sections : 1 1. Site Identification of the GNSS Monument Site Name : MECLAB Four Character ID : NCKU Monument Inscription : NCKU monitoring station IERS DOMES Number : 23606M001 CDP Number : Monument Description : PLATE Height of the Monument : 0.33 m Monument Foundation : ROOF Foundation Depth : 0 m Marker Description : Date Installed : 2012-04-20T00:00Z Geologic Characteristic : Bedrock Type : Bedrock Condition : Fracture Spacing : Fault zones nearby : NO Distance/activity : Steel plate on the rooftop based concrete Additional Information : 2. Site Location Information City or Town : Tainan State or Province : Country : Taiwan Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : -2956913.5188 Y coordinate (m) : 5075879.7174 Z coordinate (m) : 2476421.3237 Latitude (N is +) : +225948.12 Longitude (E is +) : +1201321.36 Elevation (m,ellips.) : 98.2931 Additional Information : 3. GNSS Receiver Information 3.1 Receiver Type : JAVAD TRE_G3T DELTA Satellite System : GPS+GLO+QZSS Serial Number : 00673 Firmware Version : 3.5.0a Elevation Cutoff Setting : 0 deg Date Installed : 2012-04-16T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : none Additional Information : 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : JAVRINGANT_DM SCIS Serial Number : 00475 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : Marker->ARP North Ecc(m) : Marker->ARP East Ecc(m) : Alignment from True N : Antenna Radome Type : SCIS Radome Serial Number : 0329 Antenna Cable Type : Antenna Cable Length : 70 m Date Installed : 2012-04-16T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : Effective Dates : 2012-04-16/CCYY-MM-DD Notes : 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : National Cheng Kung University Preferred Abbreviation : NCKU Mailing Address : No.1 University Road, Tainan, Taiwan Primary Contact Contact Name : Jyh-Ching Juang Telephone (primary) : +886-6-2757575#62333 Telephone (secondary) : Fax : +886-6-2763880 E-mail : juang@mail.ncku.edu.tw Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : 12. Responsible Agency (if different from 11.) Agency : Japan Aerospace Exploration Agency Preferred Abbreviation : JAXA Mailing Address : 2-1-1 Sengen, Tsukuba, Ibaraki, 305-8505 Japan Primary Contact Contact Name : Satoshi Kogure Telephone (primary) : +81-50-3362-2456 Telephone (secondary) : Fax : +81-29-868-5987 E-mail : kogure.satoshi@jaxa.jp Secondary Contact Contact Name : Kaori Kawate Telephone (primary) : +81-50-3362-6966 Telephone (secondary) : Fax : +81-29-868-5987 E-mail : kawate.kaori@jaxa.jp Additional Information : 13. More Information Primary Data Center : none Secondary Data Center : none URL for More Information : Hardcopy on File Site Map : Site Diagram : Horizon Mask : Monument Description : Site Pictures : Additional Information : Antenna Graphics with Dimensions (insert text graphic from file antenna.gra)