MRO100AUS Site Information Form (site log) International GNSS Service See Instructions at: https://files.igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Emma_Allen Date Prepared : 2022-12-15 Report Type : UPDATE If Update: Previous Site Log : (ssss_ccyymmdd.log) Modified/Added Sections : (n.n,n.n,...) 1. Site Identification of the GNSS Monument Site Name : Murchison Radio Observatory Four Character ID : MRO1 Monument Inscription : IERS DOMES Number : 59913M001 CDP Number : NONE Monument Description : Concrete pillar/stainless steel plate Height of the Monument : 1.6 m Monument Foundation : Bedrock Foundation Depth : 2.5 m Marker Description : Intersection of plate with spigot Date Installed : 2013-10-23T00:00Z Geologic Characteristic : BEDROCK Bedrock Type : Bedrock Condition : Fracture Spacing : Fault zones nearby : Distance/activity : Additional Information : 2. Site Location Information City or Town : Boolardy Station State or Province : Western Australia Country : Australia Tectonic Plate : AUSTRALIAN Approximate Position (ITRF) X coordinate (m) : -2556630.0377 Y coordinate (m) : 5097138.2766 Z coordinate (m) : -2848384.7814 Latitude (N is +) : -264147.88 Longitude (E is +) : +1163814.98 Elevation (m,ellips.) : 354.1 Additional Information : Coordinates from previous Regulation 13 : Certificate 3. GNSS Receiver Information 3.1 Receiver Type : TRIMBLE NETR9 Satellite System : GPS+GLO+GAL+BDS+QZSS Serial Number : 5207K82181 Firmware Version : 4.81 Elevation Cutoff Setting : 0 deg Date Installed : 2013-10-23T00:00Z Date Removed : 2015-06-17T00:00Z Temperature Stabiliz. : none Additional Information : 3.2 Receiver Type : TRIMBLE NETR9 Satellite System : GPS+GLO+GAL+BDS+QZSS Serial Number : 5207K82181 Firmware Version : 5.01 Elevation Cutoff Setting : 0 deg Date Installed : 2015-06-17T00:00Z Date Removed : 2016-01-08T02:00Z Temperature Stabiliz. : none Additional Information : 3.3 Receiver Type : TRIMBLE NETR9 Satellite System : GPS+GLO+GAL+BDS+QZSS Serial Number : 5207K82181 Firmware Version : 5.10 Elevation Cutoff Setting : 0 deg Date Installed : 2016-01-08T02:00Z Date Removed : 2016-12-16T00:00Z Temperature Stabiliz. : none Additional Information : 3.4 Receiver Type : TRIMBLE NETR9 Satellite System : GPS+GLO+GAL+BDS+QZSS Serial Number : 5207K82181 Firmware Version : 5.15 Elevation Cutoff Setting : 0 deg Date Installed : 2016-12-16T00:00Z Date Removed : 2017-05-01T00:00Z Temperature Stabiliz. : none Additional Information : Firmware upgrade only 3.5 Receiver Type : TRIMBLE NETR9 Satellite System : GPS+GLO+GAL+BDS+QZSS Serial Number : 5207K82181 Firmware Version : 5.22 Elevation Cutoff Setting : 0 deg Date Installed : 2017-05-01T00:00Z Date Removed : 2018-07-18T01:30Z Temperature Stabiliz. : none Additional Information : Firmware upgrade only 3.6 Receiver Type : TRIMBLE NETR9 Satellite System : QZSS+GPS+GLO+GAL+BDS Serial Number : 5207K82181 Firmware Version : 5.33 Elevation Cutoff Setting : 0 deg Date Installed : 2018-07-18T01:30Z Date Removed : 2018-10-22T05:32Z Temperature Stabiliz. : none Additional Information : Firmware upgrade only 3.7 Receiver Type : TRIMBLE NETR9 Satellite System : GPS+QZSS+GLO+GAL+BDS Serial Number : 5207K82181 Firmware Version : 5.37 Elevation Cutoff Setting : 0 deg Date Installed : 2018-10-22T05:37Z Date Removed : 2020-04-03T05:44Z Temperature Stabiliz. : none Additional Information : Firmware upgrade only 3.8 Receiver Type : TRIMBLE NETR9 Satellite System : GPS+QZSS+GLO+GAL+BDS Serial Number : 5207K82181 Firmware Version : 5.44 Elevation Cutoff Setting : 0 deg Date Installed : 2020-04-03T05:44Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : none Additional Information : Firmware Upgrade Only 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TRM59800.00 NONE Serial Number : 5220354494 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 000.0000 Marker->ARP North Ecc(m) : 000.0000 Marker->ARP East Ecc(m) : 000.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : RG58 + Optic Fibre Antenna Cable Length : Date Installed : 2013-10-23T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : Effective Dates : 2013-10-23/CCYY-MM-DD Notes : 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : PAROSCIENTIFIC MET4 Manufacturer : Paroscientific Serial Number : DQ151834 Data Sampling Interval : 30 sec Accuracy (% rel h) : 2.00 Aspiration : UNASPIRATED Height Diff to Ant : 0.0 m Calibration date : (CCYY-MM-DD) Effective Dates : 2013-11-01/CCYY-MM-DD Notes : 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : PAROSCIENTIFIC MET4 Manufacturer : Paroscientific Serial Number : DQ151834 Data Sampling Interval : 30 sec Accuracy : 0.08 hPa Height Diff to Ant : 0.0 m Calibration date : (CCYY-MM-DD) Effective Dates : 2013-11-01/CCYY-MM-DD Notes : 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : PAROSCIENTIFIC MET4 Manufacturer : Paroscientific Serial Number : DQ151834 Data Sampling Interval : 30 sec Accuracy : 0.50 deg C Aspiration : UNASPIRATED Height Diff to Ant : 0.0 m Calibration date : Effective Dates : 2013-11-01/CCYY-MM-DD Notes : 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Geoscience Australia Preferred Abbreviation : Mailing Address : GPO Box 378 : Canberra ACT 2601 : AUSTRALIA : Canberra : 2601 : Australia Primary Contact Contact Name : Geoscience Australia Telephone (primary) : +61 2 6249 9004 Telephone (secondary) : +61 2 6249 9111 Fax : E-mail : gnss@ga.gov.au Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : 12. Responsible Agency (if different from 11.) Agency : Geoscience Australia Preferred Abbreviation : Mailing Address : GPO Box 378 : Canberra ACT 2601 : AUSTRALIA : Canberra : 2601 : Australia Primary Contact Contact Name : Geoscience Australia Telephone (primary) : +61 2 6249 9004 Telephone (secondary) : +61 2 6249 9111 Fax : E-mail : gnss@ga.gov.au Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : 13. More Information Primary Data Center : GA Secondary Data Center : CDDIS URL for More Information : http://www.ga.gov.au Hardcopy on File Site Map : Y Site Diagram : Y Horizon Mask : Y Monument Description : Y Site Pictures : Y Additional Information : Antenna Graphics with Dimensions (insert text graphic from file antenna.gra)