MEDI Site Information Form (site log) International GNSS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : GIUSEPPE COLUCCI Date Prepared : 2016-09-19 Report Type : UPDATE If Update: Previous Site Log : medi_20160905.log Modified/Added Sections : 6.20, 6.21 1. Site Identification of the GNSS Monument Site Name : Medicina(BO) Four Character ID : MEDI Monument Inscription : Pillar Marker 'R' IERS DOMES Number : 12711M003 CDP Number : Monument Description : PILLAR Height of the Monument : 1.2 m Monument Foundation : CONCRETE BLOCK Foundation Depth : 8 m Marker Description : CHISELLED CROSS Date Installed : 1995-07-28T00:00Z Geologic Characteristic : SAND (alluvial plain) Bedrock Type : Bedrock Condition : Fracture Spacing : Fault zones nearby : Distance/activity : Additional Information : 2. Site Location Information City or Town : Medicina State or Province : EMILIA-ROMAGNA Country : Italy Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : 4461400.894 Y coordinate (m) : 919593.443 Z coordinate (m) : 4449504.669 Latitude (N is +) : +443111.64 Longitude (E is +) : +0113848.48 Elevation (m,ellips.) : 50.0 Additional Information : Near Bologna 3. GNSS Receiver Information 3.1 Receiver Type : ROGUE SNR-8100 Satellite System : GPS Serial Number : 153 Firmware Version : 3.2.32.1 Elevation Cutoff Setting : 15 deg Date Installed : 1995-07-28T00:00Z Date Removed : 2001-04-02T00:00Z Temperature Stabiliz. : 20.0 +/- Additional Information : 3.2 Receiver Type : TRIMBLE 4000SSI Satellite System : GPS Serial Number : 22774 Firmware Version : Nav 7.29 Sig 3.07 Elevation Cutoff Setting : 5 deg Date Installed : 2001-04-03T00:00Z Date Removed : 2015-08-03T15:30Z Temperature Stabiliz. : 20.0 +/- Additional Information : 3.3 Receiver Type : TRIMBLE 4000SSI Satellite System : GPS Serial Number : 22774 Firmware Version : Nav 7.29 Sig 3.07 Elevation Cutoff Setting : 0 deg Date Installed : 2015-08-03T15:30Z Date Removed : 2016-09-01T10:00Z Temperature Stabiliz. : Additional Information : 3.4 Receiver Type : LEICA GR10 Satellite System : GPS+GLO+GAL+BDS+SBAS Serial Number : 1704161 Firmware Version : 4.00/6.522 Elevation Cutoff Setting : 0 deg Date Installed : 2016-09-01T12:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : Additional Information : 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : AOAD/M_T NONE Serial Number : 450 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Belden H1000 Antenna Cable Length : 100 m Date Installed : 1995-07-28T00:00Z Date Removed : 2001-04-02T00:00Z Additional Information : 4.2 Antenna Type : TRM29659.00 NONE Serial Number : 27655 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Belden H1000 Antenna Cable Length : 100 m Date Installed : 2001-04-03T00:00Z Date Removed : 2016-09-01T10:00Z Additional Information : During the week 23-27 March 2009 the antenna was : deeply cleaned up from very heavy dirtiness, : mainly due to birds droppings. 4.3 Antenna Type : LEIAR20 NONE Serial Number : 18345001 Antenna Reference Point : BAM Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Belden H1000 Antenna Cable Length : 100 m Date Installed : 2016-09-01T12:00Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.1 Tied Marker Name : SLR (MARKER O) Tied Marker Usage : Mobile SLR Tied Marker CDP Number : 7546 Tied Marker DOMES Number : 12711M002 Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : -1.386 dy (m) : -26.495 dz (m) : 5.965 Accuracy (mm) : 1.5 mm Survey method : TRIANGULATION Date Measured : 1995-09-07T00:00Z Additional Information : 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : EXTERNAL H-MASER Input Frequency : 5 MHz Effective Dates : 1995-10-25/2003-06-17 Notes : 6.2 Standard Type : INTERNAL Input Frequency : Effective Dates : 2003-06-18/2003-07-17 Notes : 6.3 Standard Type : EXTERNAL H-MASER Input Frequency : 5 MHz Effective Dates : 2003-07-18/2003-12-14 Notes : 6.4 Standard Type : INTERNAL Input Frequency : Effective Dates : 2003-12-16/2004-07-15 Notes : 6.5 Standard Type : EXTERNAL H-MASER Input Frequency : 5 MHz Effective Dates : 2004-07-15/2006-08-21 Notes : 6.6 Standard Type : INTERNAL Input Frequency : Effective Dates : 2006-08-22/2006-11-21 Notes : 6.7 Standard Type : EXTERNAL H-MASER Input Frequency : 10 MHz Effective Dates : 2006-11-21/2007-09-17 Notes : 6.8 Standard Type : INTERNAL Input Frequency : Effective Dates : 2007-09-17/2007-09-26 Notes : 6.9 Standard Type : EXTERNAL H-MASER Input Frequency : 10 MHz Effective Dates : 2007-09-26/2009-04-15 Notes : 6.10 Standard Type : INTERNAL Input Frequency : Effective Dates : 2009-04-15/2009-04-20 Notes : 6.11 Standard Type : EXTERNAL H-MASER Input Frequency : 10 MHz Effective Dates : 2009-04-20/2009-11-12 Notes : 6.12 Standard Type : INTERNAL Input Frequency : Effective Dates : 2009-11-12/2009-11-19 Notes : 6.13 Standard Type : EXTERNAL H-MASER Input Frequency : 10 MHz Effective Dates : 2009-11-19/2010-02-09 Notes : 6.14 Standard Type : INTERNAL Input Frequency : Effective Dates : 2010-02-09/2010-02-18 Notes : 6.15 Standard Type : EXTERNAL H-MASER Input Frequency : 10 MHz Effective Dates : 2010-02-18/2010-02-19 Notes : 6.16 Standard Type : INTERNAL Input Frequency : Effective Dates : 2010-02-19/2010-03-05 Notes : 6.17 Standard Type : EXTERNAL H-MASER Input Frequency : 10 MHz Effective Dates : 2010-03-05/2013-03-14 Notes : 6.18 Standard Type : INTERNAL Input Frequency : Effective Dates : 2013-03-14/2013-06-07 Notes : 6.19 Standard Type : EXTERNAL H-MASER Input Frequency : 10 MHz Effective Dates : 2013-06-07/2016-09-01 Notes : 6.20 Standard Type : INTERNAL Input Frequency : Effective Dates : 2016-09-01/2016-09-19 Notes : 6.21 Standard Type : EXTERNAL H-MASER Input Frequency : 10 MHz Effective Dates : 2016-09-19/CCYY-MM-DD Notes : 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : SLR Status : MOBILE Effective Dates : 1980-08-22/CCYY-MM-DD Notes : 7.2 Instrumentation Type : VLBI Status : PERMANENT Effective Dates : 1984-02-18/CCYY-MM-DD Notes : 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : e-geos S.p.A. - una societ? ASI/Telespazio Preferred Abbreviation : TPZ Mailing Address : P.O.BOX OPEN - 75100 Matera, ITALY Primary Contact Contact Name : G. Colucci Telephone (primary) : ++39.0835.377574 Telephone (secondary) : Fax : E-mail : giuseppe.colucci@e-geos.it Secondary Contact Contact Name : R. Faccia, F. Ambrico Telephone (primary) : ++39.0835.377541 Telephone (secondary) : Fax : E-mail : gpsgeo@hp835.mt.asi.it Additional Information : 12. Responsible Agency (if different from 11.) Agency : Agenzia Spaziale Italiana Preferred Abbreviation : ASI Mailing Address : P.O.BOX OPEN - 75100 Matera, ITALY Primary Contact Contact Name : Dott. Giuseppe Bianco Telephone (primary) : ++39.0835.377509 Telephone (secondary) : Fax : ++39.0835.339005 E-mail : giuseppe.bianco@asi.it Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : 13. More Information Primary Data Center : ASI Secondary Data Center : BKG URL for More Information : Hardcopy on File Site Map : Site Diagram : Horizon Mask : Monument Description : Site Pictures : Additional Information : Survey of site Antenna Graphics with Dimensions TURBOROGUE: DORNE MARGOLIN T (Allen Osborne Associates, Inc. mod. 7490400-4) (July 9, 1996 - ...) ----- / + \ <-- 0.128 L2 | + | <-- 0.110 L1 +--------------------------------------------------+ <-- 0.102 TCR | | | | | | | | | | +-----------------+-------------+------------------+ <-- 0.035 BCR | | | | +------x------+ <-- 0.000 ARP ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center TCR: Top of Chokering BCR: Bottom of Chokering ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ TRM29659.00 Trimble L1/L2 Dorne Margolin element with chokerings Model 29659.00 ----- / + \ <-- 0.1280 L2 | + | <-- 0.1100 L1 +--------------------------------------------------+ <-- 0.1020 TCR | | | | | | | | +----------------------------------------------------+ <-- 0.0380 +------------------+-------------+-------------------+ <-- 0.0350 BCR | | | | +------x------+ <-- 0.0000 BPA ARP: Antenna Reference Point