MEDI Site Information Form See Instructions at: International GPS Service ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : EUSTACHIO LUNALBI Date Prepared : 2004-07-15 Report Type : UPDATE If Update: Previous Site Log : medi_20030722.log Modified/Added Sections : 6.4, 6.5 1. Site Identification of the GNSS Monument Site Name : Medicina(BO) Four Character ID : MEDI Monument Inscription : Pillar Marker "R" IERS DOMES Number : 12711M003 CDP Number : (A4) Monument Description : PILLAR Height of the Monument : 1.2 m Monument Foundation : CONCRETE BLOCK Foundation Depth : 8 m Marker Description : CHISELLED CROSS Date Installed : 1995-07-28 Geologic Characteristic : SAND (alluvial plain) Bedrock Type : (IGNEOUS/METAMORPHIC/SEDIMENTARY) Bedrock Condition : (FRESH/JOINTED/WEATHERED) Fracture Spacing : (1-10 cm/11-50 cm/51-200 cm/over 200 cm) Fault zones nearby : (YES/NO/Name of the zone) Distance/activity : (multiple lines) Additional Information : (multiple lines) 2. Site Location Information City or Town : Medicina State or Province : EMILIA-ROMAGNA Country : Italy Tectonic Plate : ADRIATIC-AFRICAN PLATE Approximate Position (ITRF) X coordinate (m) : 4461400.894 Y coordinate (m) : 919593.443 Z coordinate (m) : 4449504.669 Latitude (N is +) : +443111.64 Longitude (E is +) : +0113848.48 Elevation (m,ellips.) : 00050.0 Additional Information : Near Bologna 3. GNSS Receiver Information 3.1 Receiver Type : ROGUE SNR-8100 Satellite System : GPS Serial Number : 153 Firmware Version : 3.2.32.1 Elevation Cutoff Setting : 15 Date Installed : 1995-07-28 Date Removed : 2001-04-02 Temperature Stabiliz. : 20B0C +-5B0C Additional Information : (multiple lines) 3.2 Receiver Type : TRIMBLE 4000SSI Satellite System : GPS Serial Number : 22774 Firmware Version : Nav 7.29 Sig 3.07 Elevation Cutoff Setting : 5 Date Installed : 2001-04-03 Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : 20B0C +-5B0C Additional Information : (multiple lines) 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS/GLONASS/GPS+GLONASS) Serial Number : (A5) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : AOAD/M_T NONE Serial Number : 450 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 000.0000 Marker->ARP North Ecc(m) : 000.0000 Marker->ARP East Ecc(m) : 000.0000 Alignment from True N : 0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Belden H1000 Antenna Cable Length : 100 Date Installed : 1995-07-28 Date Removed : 2001-04-02 Additional Information : 4.2 Antenna Type : TRM29659.00 NONE Serial Number : 27655 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 000.0000 Marker->ARP North Ecc(m) : 000.0000 Marker->ARP East Ecc(m) : 000.0000 Alignment from True N : 0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Belden H1000 Antenna Cable Length : 100 Date Installed : 2001-04-03 Date Removed : CCYY-MM-DDThh:mmZ Additional Information : 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.1 Tied Marker Name : SLR (MARKER O) Tied Marker Usage : Mobile SLR Tied Marker CDP Number : 7546 Tied Marker DOMES Number : 12711M002 Differential Components from GNSS Marker to the tied monument dx (m) : -1.386 dy (m) : -26.495 dz (m) : 5.965 Accuracy (mm) : 1.5 Survey method : TRIANGULATION Date Measured : 1995-09-07 Additional Information : (multiple lines) 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : dy (m) : dz (m) : Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : H-MASER Input Frequency : 5 MHz Effective Dates : 1995-10-25/2003-06-17 Notes : (multiple lines) 6.2 Standard Type : INTERNAL Input Frequency : Effective Dates : 2003-06-18/2003-07-17 Notes : (multiple lines) 6.3 Standard Type : H-MASER Input Frequency : 5 MHz Effective Dates : 2003-07-18/2003-12-14 Notes : (multiple lines) 6.4 Standard Type : INTERNAL Input Frequency : Effective Dates : 2003-12-16/2004-07-15 Notes : (multiple lines) 6.5 Standard Type : H-MASER Input Frequency : 5 MHz Effective Dates : 2004-07-15/CCYY-MM-DD Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : SLR Status : MOBILE Effective Dates : 1980-08-22/CCYY-MM-DD Notes : (multiple lines) 7.2 Instrumentation Type : VLBI Status : PERMANENT Effective Dates : 1984-02-18/CCYY-MM-DD Notes : (multiple lines) 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degredations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Telespazio S.p.A. Preferred Abbreviation : TPZ Mailing Address : P.O.BOX OPEN - 75100 Matera, ITALY Primary Contact Contact Name : F. Ambrico, R. Faccia, G. Ramundo Telephone (primary) : ++39.0835.377293 Telephone (secondary) : Fax : ++39.0835.334951 E-mail : retegps@asi.it Secondary Contact Contact Name : Domenico Del Rosso Telephone (primary) : ++39.0835.377203 Telephone (secondary) : Fax : ++39.0835.334951 E-mail : domenico_delrosso@Telespazio.it Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : Agenzia Spaziale Italiana Preferred Abbreviation : ASI Mailing Address : P.O.BOX OPEN - 75100 Matera, ITALY Primary Contact Contact Name : Dott. Francesco VESPE Telephone (primary) : ++39.0835.377211 Telephone (secondary) : Fax : ++39.0835.339005 E-mail : francesco.vespe@asi.it Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : ASI Secondary Data Center : BKGI URL for More Information : Hardcopy on File Site Map : (Y or URL) Site Diagram : (Y or URL) Horizon Mask : (Y or URL) Monument Description : (Y or URL) Site Pictures : (Y or URL) Additional Information : Survey of site Antenna Graphics with Dimensions TURBOROGUE: DORNE MARGOLIN T (Allen Osborne Associates, Inc. mod. 7490400-4) (July 9, 1996 - ...) ----- / + \ <-- 0.128 L2 | + | <-- 0.110 L1 +--------------------------------------------------+ <-- 0.102 TCR | | | | | | | | | | +-----------------+-------------+------------------+ <-- 0.035 BCR | | | | +------x------+ <-- 0.000 ARP ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center TCR: Top of Chokering BCR: Bottom of Chokering TRM29659.00 Trimble L1/L2 Dorne Margolin element with chokerings Model 29659.00 ----- / + \ <-- 0.1280 L2 | + | <-- 0.1100 L1 +--------------------------------------------------+ <-- 0.1020 TCR | | | | | | | | +----------------------------------------------------+ <-- 0.0380 +------------------+-------------+-------------------+ <-- 0.0350 BCR | | | | +------x------+ <-- 0.000 BPA ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center BPA: Bottom of Preamplifier BCR: Bottom of Chokering