MCHL Site Information Form (site log) International GNSS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Ted Zhou Date Prepared : 2015-09-22 Report Type : UPDATE If Update: Previous Site Log : mchl_20150617.log Modified/Added Sections : 3.2,3.3 1. Site Identification of the GNSS Monument Site Name : Mitchell Four Character ID : MCHL Monument Inscription : IERS DOMES Number : 59905M001 CDP Number : NONE Monument Description : PILLAR Height of the Monument : 1.5 m Monument Foundation : STEEL RODS / CONCRETE BLOCK Foundation Depth : 1.5 m Marker Description : STAINLESS STEEL PLATE, THREADED SPIGOT Date Installed : 2014-04-09T00:00Z Geologic Characteristic : BEDROCK Bedrock Type : SEDIMENTARY Bedrock Condition : Fracture Spacing : Fault zones nearby : NO Distance/activity : Additional Information : 2. Site Location Information City or Town : Mitchell State or Province : Queensland Country : Australia Tectonic Plate : AUSTRALIAN Approximate Position (ITRF) X coordinate (m) : -4857858.740 Y coordinate (m) : 3018464.424 Z coordinate (m) : -2814983.502 Latitude (N is +) : -262132.05666 Longitude (E is +) : +1480841.85761 Elevation (m,ellips.) : 534.593 Additional Information : 3. GNSS Receiver Information 3.1 Receiver Type : TRIMBLE NETR9 Satellite System : GPS+GLO+GAL+BDS+QZSS Serial Number : 5207K82242 Firmware Version : 4.85 Elevation Cutoff Setting : 0 deg Date Installed : 2014-04-09T00:00Z Date Removed : 2015-06-17T00:00Z Temperature Stabiliz. : none Additional Information : 3.2 Receiver Type : TRIMBLE NETR9 Satellite System : GPS+GLO+GAL+BDS+QZSS Serial Number : 5207K82242 Firmware Version : 5.01 Elevation Cutoff Setting : 0 deg Date Installed : 2015-06-17T00:00Z Date Removed : 2015-09-22T00:00Z Temperature Stabiliz. : none Additional Information : 3.3 Receiver Type : TRIMBLE NETR9 Satellite System : GPS+GLO+GAL+BDS+QZSS Serial Number : 5207K82242 Firmware Version : 5.10 Elevation Cutoff Setting : 0 deg Date Installed : 2015-09-22T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : none Additional Information : Firmware update only 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TRM59800.00 NONE Serial Number : 5220354470 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : LMR400 Antenna Cable Length : 20 m Date Installed : 2014-04-09T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.1 Tied Marker Name : RM01 Tied Marker Usage : LOCAL CONTROL Tied Marker CDP Number : Tied Marker DOMES Number : Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : -9.8843 dy (m) : -4.6396 dz (m) : 16.4564 Accuracy (mm) : 1 mm Survey method : TRIANGULATION + LEVELLING Date Measured : 2014-04-09T00:00Z Additional Information : 5.2 Tied Marker Name : RM02 Tied Marker Usage : LOCAL CONTROL Tied Marker CDP Number : Tied Marker DOMES Number : Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : 5.8961 dy (m) : -8.1067 dz (m) : -14.2758 Accuracy (mm) : 1 mm Survey method : TRIANGULATION + LEVELLING Date Measured : 2014-04-09T00:00Z Additional Information : 5.3 Tied Marker Name : RM03 Tied Marker Usage : LOCAL CONTROL Tied Marker CDP Number : Tied Marker DOMES Number : Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : 10.0827 dy (m) : 16.4491 dz (m) : 3.5504 Accuracy (mm) : 1 mm Survey method : TRIANGULATION + LEVELLING Date Measured : 2014-04-09T00:00Z Additional Information : 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : Effective Dates : 2014-04-09/CCYY-MM-DD Notes : 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : PAROSCIENTIFIC MET4 Manufacturer : Paroscientific Serial Number : DQ60956584 Data Sampling Interval : 30 sec Accuracy (% rel h) : 2.00 Aspiration : UNASPIRATED Height Diff to Ant : -0.0676 m Calibration date : (CCYY-MM-DD) Effective Dates : 2014-04-09/CCYY-MM-DD Notes : 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : PAROSCIENTIFIC MET4 Manufacturer : Paroscientific Serial Number : DQ60956584 Data Sampling Interval : 30 sec Accuracy : 0.08 hPa Height Diff to Ant : -0.0676 m Calibration date : (CCYY-MM-DD) Effective Dates : 2014-04-09/CCYY-MM-DD Notes : 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : PAROSCIENTIFIC MET4 Manufacturer : Paroscientific Serial Number : DQ60956584 Data Sampling Interval : 30 sec Accuracy : 0.5 deg C Aspiration : UNASPIRATED Height Diff to Ant : -0.0676 m Calibration date : Effective Dates : 2014-04-09/CCYY-MM-DD Notes : 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.1 Signal Obstructions : Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Geoscience Australia Preferred Abbreviation : GA Mailing Address : GPO Box 378 : Canberra ACT 2601 : AUSTRALIA Primary Contact Contact Name : Ryan Ruddick Telephone (primary) : +61 2 6249 9426 Telephone (secondary) : +61 2 6249 9111 Fax : E-mail : geodesy@ga.gov.au Secondary Contact Contact Name : Nicholas Brown Telephone (primary) : +61 2 6249 9831 Telephone (secondary) : +61 2 6249 9111 Fax : E-mail : geodesy@ga.gov.au Additional Information : 12. Responsible Agency (if different from 11.) Agency : Geoscience Australia Preferred Abbreviation : GA Mailing Address : GPO Box 378 : Canberra ACT 2601 : AUSTRALIA Primary Contact Contact Name : Ryan Ruddick Telephone (primary) : +61 2 6249 9426 Telephone (secondary) : +61 2 6249 9111 Fax : E-mail : geodesy@ga.gov.au Secondary Contact Contact Name : Nicholas Brown Telephone (primary) : +61 2 6249 9831 Telephone (secondary) : +61 2 6249 9111 Fax : E-mail : geodesy@ga.gov.au Additional Information : 13. More Information Primary Data Center : GA Secondary Data Center : CDDIS URL for More Information : http://www.ga.gov.au Hardcopy on File Site Map : Y Site Diagram : Y Horizon Mask : Y Monument Description : Y Site Pictures : Y Additional Information : Antenna Graphics with Dimensions TRM59800.00 ----- / \ | | +-------------------------------------------------+ <-- 0.1020 TCR | | | | | | | | +-+-------------------------------------------------+-+ <-- 0.0381 +-------------------+-------------+-------------------+ <-- 0.0350 BCR | | =| | +------x------+ <-- 0.0000 BPA=ARP <-- 0.3810 -->