LAMA00POL Site Information Form (site log) International GNSS Service See Instructions at: ftp://igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Adam Fron Date Prepared : 2020-07-27 Report Type : UPDATE If Update: Previous Site Log : lama_20180823.log Modified/Added Sections : 11, 13 1. Site Identification of the GNSS Monument Site Name : LAMKOWKO Four Character ID : LAMA Monument Inscription : LAMA IERS DOMES Number : 12209M001 CDP Number : Monument Description : PILLAR/CONCRETE Height of the Monument : 1.5 m Monument Foundation : CONCRETE BLOCK Foundation Depth : 2.6 m Marker Description : Date Installed : 1992-03-31T00:00Z Geologic Characteristic : SAND Bedrock Type : SEDIMENTARY Bedrock Condition : FRESH Fracture Spacing : Fault zones nearby : NO Distance/activity : Additional Information : IGS'92 Fiducial Station : CERGOP Station : SAGET and EXTENDED SAGET geodynamic networks : Station : EUREF GPS mark No 302 2. Site Location Information City or Town : Olsztyn State or Province : Warmia and Mazury Country : Poland Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : 3524523.000 Y coordinate (m) : 1329693.000 Z coordinate (m) : 5129846.000 Latitude (N is +) : +535332.64 Longitude (E is +) : +0204011.76 Elevation (m,ellips.) : 186.7 Additional Information : 3. GNSS Receiver Information 3.1 Receiver Type : ROGUE SNR-8000 Satellite System : GPS Serial Number : T-228 Firmware Version : TURBOROGUE Elevation Cutoff Setting : 5 deg Date Installed : 1994-12-01T00:00Z Date Removed : 1996-02-25T00:00Z Temperature Stabiliz. : Additional Information : Damaged on 25-FEB-1996 3.2 Receiver Type : ASHTECH Z-XII3 Satellite System : GPS Serial Number : 209 Firmware Version : ASHTECH 1E82 Elevation Cutoff Setting : 5 deg Date Installed : 1996-04-17T00:00Z Date Removed : 1996-07-22T00:00Z Temperature Stabiliz. : Additional Information : 3.3 Receiver Type : ROGUE SNR-8000 Satellite System : GPS Serial Number : T-228 Firmware Version : TURBOROGUE Elevation Cutoff Setting : 5 deg Date Installed : 1996-07-23T00:00Z Date Removed : 1998-04-25T00:00Z Temperature Stabiliz. : Additional Information : Damaged on 25-APR-1998 3.4 Receiver Type : ASHTECH Z-XII3 Satellite System : GPS Serial Number : 1217 Firmware Version : 1G00 Elevation Cutoff Setting : 5 deg Date Installed : 1998-04-26T00:00Z Date Removed : 1998-05-01T00:00Z Temperature Stabiliz. : Additional Information : 3.5 Receiver Type : ASHTECH Z-XII3 Satellite System : GPS Serial Number : 209 Firmware Version : 1E82 Elevation Cutoff Setting : 5 deg Date Installed : 1998-05-02T00:00Z Date Removed : 1999-07-18T00:00Z Temperature Stabiliz. : Additional Information : Firmware update 3.6 Receiver Type : ASHTECH Z-XII3 Satellite System : GPS Serial Number : 209 Firmware Version : CC00 Elevation Cutoff Setting : 5 deg Date Installed : 1999-07-19T00:00Z Date Removed : 2007-11-17T19:00Z Temperature Stabiliz. : Additional Information : 3.7 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 351072 Firmware Version : 4.10/3.012 Elevation Cutoff Setting : 0 deg Date Installed : 2007-11-17T19:00Z Date Removed : 2008-02-16T08:00Z Temperature Stabiliz. : Additional Information : 3.8 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 351072 Firmware Version : 5.62/3.014 Elevation Cutoff Setting : 0 deg Date Installed : 2008-02-16T08:00Z Date Removed : 2008-07-28T11:00Z Temperature Stabiliz. : Additional Information : 3.9 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 351072 Firmware Version : 6.00/3.015 Elevation Cutoff Setting : 0 deg Date Installed : 2008-07-28T11:00Z Date Removed : 2009-03-19T10:00Z Temperature Stabiliz. : Additional Information : 3.10 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 351072 Firmware Version : 7.01/3.016 Elevation Cutoff Setting : 0 deg Date Installed : 2009-03-19T10:00Z Date Removed : 2009-04-21T17:00Z Temperature Stabiliz. : Additional Information : 3.11 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 351072 Firmware Version : 7.02/3.017 Elevation Cutoff Setting : 0 deg Date Installed : 2009-04-21T17:00Z Date Removed : 2010-05-04T06:00Z Temperature Stabiliz. : Additional Information : 3.12 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 351072 Firmware Version : 7.80/3.019 Elevation Cutoff Setting : 0 deg Date Installed : 2010-05-04T06:00Z Date Removed : 2011-02-02T06:00Z Temperature Stabiliz. : Additional Information : 3.13 Receiver Type : LEICA GRX1200+GNSS Satellite System : GPS+GLO Serial Number : 351072 Firmware Version : 8.10/4.007 Elevation Cutoff Setting : 0 deg Date Installed : 2011-02-09T08:30Z Date Removed : 2018-08-05T09:00Z Temperature Stabiliz. : Additional Information : 3.14 Receiver Type : LEICA GRX1200+GNSS Satellite System : GPS+GLO Serial Number : 351072 Firmware Version : 9.20/6.112 Elevation Cutoff Setting : 0 deg Date Installed : 2018-08-17T14:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : Additional Information : 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : AOAD/M_T NONE Serial Number : 263 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0610 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Antenna Cable Length : 25 m Date Installed : 1994-12-01T00:00Z Date Removed : 2000-10-06T00:00Z Additional Information : Between 26-APR-1998 and 1-MAY-1998 : RINEX contained wrong info : about antenna type 4.2 Antenna Type : ASH700936F_C SNOW Serial Number : 155 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0610 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : SNOW Radome Serial Number : Antenna Cable Type : Antenna Cable Length : 25 m Date Installed : 2000-10-06T00:00Z Date Removed : 2007-11-17T19:00Z Additional Information : Ashtech original radome 4.3 Antenna Type : LEIAT504GG LEIS Serial Number : 200033 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0600 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : LEIS Radome Serial Number : Antenna Cable Type : Antenna Cable Length : 25 m Date Installed : 2007-11-17T19:00Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.1 Tied Marker Name : LAM1 Tied Marker Usage : CONTROL Tied Marker CDP Number : Tied Marker DOMES Number : Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : 52.690 dy (m) : 12.389 dz (m) : -39.669 Accuracy (mm) : 1 mm Survey method : GPS CAMPAIGN/TRIANGULATION Date Measured : 1993-07-16T00:00Z Additional Information : 5.2 Tied Marker Name : LAM2 Tied Marker Usage : CONTROL Tied Marker CDP Number : Tied Marker DOMES Number : Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : -50.294 dy (m) : -35.054 dz (m) : 43.871 Accuracy (mm) : 1 mm Survey method : GPS CAMPAIGN/TRIANGULATION Date Measured : 1993-07-16T00:00Z Additional Information : 5.3 Tied Marker Name : LAM3 Tied Marker Usage : CONTROL Tied Marker CDP Number : Tied Marker DOMES Number : Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : -45.829 dy (m) : 39.580 dz (m) : 18.508 Accuracy (mm) : 1 mm Survey method : GPS CAMPAIGN/TRIANGULATION Date Measured : 1993-07-16T00:00Z Additional Information : 5.4 Tied Marker Name : LAM5 Tied Marker Usage : CONTROL, DGPS ref. station Tied Marker CDP Number : Tied Marker DOMES Number : Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : 98.290 dy (m) : 81.945 dz (m) : -75.120 Accuracy (mm) : 1 mm Survey method : GPS CAMPAIGN/TRIANGULATION Date Measured : 2000-06-16T00:00Z Additional Information : 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : EXTERNAL RUBIDIUM Input Frequency : 5 MHz Effective Dates : 1996-07-23/1997-07-30 Notes : 6.2 Standard Type : INTERNAL Input Frequency : Effective Dates : 1997-07-31/1998-06-11 Notes : 6.3 Standard Type : EXTERNAL RUBIDIUM Input Frequency : 5 MHz Effective Dates : 1998-06-12/1999-05-02 Notes : 6.4 Standard Type : INTERNAL Input Frequency : Effective Dates : 1999-05-03/2001-01-27 Notes : 6.5 Standard Type : EXTERNAL RUBIDIUM Input Frequency : 5 MHz Effective Dates : 2001-01-28/2001-07-24 Notes : 6.6 Standard Type : INTERNAL Input Frequency : Effective Dates : 2001-07-24/CCYY-MM-DD Notes : 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : LB-710 HB Manufacturer : LAB EL, POLAND Serial Number : Data Sampling Interval : 600 sec Accuracy (% rel h) : Aspiration : NATURAL Height Diff to Ant : 0 m Calibration date : 2001-05-20 Effective Dates : 2001-05-25/2007-11-17 Notes : 8.1.2 Humidity Sensor Model : MET3A Manufacturer : PAROSCIENTIFIC, INC Serial Number : 102592 Data Sampling Interval : 300 sec Accuracy (% rel h) : 2 Aspiration : FAN Height Diff to Ant : 0 m Calibration date : 2007-08-14 Effective Dates : 2007-11-17/2008-06-26 Notes : 8.1.3 Humidity Sensor Model : MET4A Manufacturer : PAROSCIENTIFIC, INC Serial Number : 106565 Data Sampling Interval : 300 sec Accuracy (% rel h) : 2 Aspiration : FAN Height Diff to Ant : 0 m Calibration date : 2008-06-20 Effective Dates : 2008-06-26/CCYY-MM-DD Notes : 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : LB-716 Manufacturer : LAB EL, POLAND Serial Number : Data Sampling Interval : 600 sec Accuracy : 0.5 hPa Height Diff to Ant : 0 m Calibration date : 2001-05-20 Effective Dates : 2001-05-25/2007-11-17 Notes : 8.2.2 Pressure Sensor Model : MET3A Manufacturer : PAROSCIENTIFIC, INC Serial Number : 102592 Data Sampling Interval : 300 sec Accuracy : 0.08 hPa Height Diff to Ant : 0 m Calibration date : 2007-08-14 Effective Dates : 2007-11-17/2008-06-26 Notes : 8.2.3 Pressure Sensor Model : MET4A Manufacturer : PAROSCIENTIFIC, INC Serial Number : 106565 Data Sampling Interval : 300 sec Accuracy : 0.08 hPa Height Diff to Ant : 0 m Calibration date : 2008-06-20 Effective Dates : 2008-06-26/CCYY-MM-DD Notes : 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : LB-710 HB Manufacturer : LAB EL, POLAND Serial Number : Data Sampling Interval : 600 sec Accuracy : 0.1 deg C Aspiration : NATURAL Height Diff to Ant : 0 m Calibration date : 2001-05-20 Effective Dates : 2001-05-25/2007-11-17 Notes : 8.3.2 Temp. Sensor Model : MET3A Manufacturer : PAROSCIENTIFIC, INC Serial Number : 102592 Data Sampling Interval : 300 sec Accuracy : 0.1 deg C Aspiration : FAN Height Diff to Ant : 0 m Calibration date : 2007-08-14 Effective Dates : 2007-11-17/2008-06-26 Notes : 8.3.3 Temp. Sensor Model : MET4A Manufacturer : PAROSCIENTIFIC, INC Serial Number : 106565 Data Sampling Interval : 300 sec Accuracy : 0.2 deg C Aspiration : FAN Height Diff to Ant : 0 m Calibration date : 2008-06-20 Effective Dates : 2008-06-26/CCYY-MM-DD Notes : 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.1 Date : 2000-04-01/2000-10-06 Event : GPS Antenna malfunction (TRACKED FEW GPSSAT.) 10.2 Date : 2005-12-30/2006-02-10 Event : Due to heavy snowfall in the region theantenna : was covered by snow 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : University of Warmia and Mazury in Olsztyn : Space Radio-Diagnostics Research Centre Preferred Abbreviation : UWM Mailing Address : Prawocheñskiego Street 9 : 10-719 Olsztyn : Poland Primary Contact Contact Name : Adam Fron Telephone (primary) : +48 89 523 42 41 Telephone (secondary) : +48 89 514 16 84 Fax : +48 89 514 16 85 E-mail : adam.fron@uwm.edu.pl Secondary Contact Contact Name : Jacek Kapcia Telephone (primary) : +48 89 514 16 84 Telephone (secondary) : Fax : +48 89 514 16 85 E-mail : lamk@uwm.edu.pl Additional Information : 12. Responsible Agency (if different from 11.) Agency : Preferred Abbreviation : Mailing Address : Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : 13. More Information Primary Data Center : BEV Secondary Data Center : BKG URL for More Information : http://www.epncb.oma.be/_networkdata/siteinfo4on Hardcopy on File Site Map : Site Diagram : X Horizon Mask : X Monument Description : X Site Pictures : 1 Additional Information : Antenna Graphics with Dimensions LEIAT504GG +-------+ <-- 0.1393 / + \ | + | +-----------------+-------------+------------------+ <-- 0.1012 TCR | | | | | | | | +-+--------------------------------------------------+-+ +-------------------+-------------+--------------------+ <-- 0.0345 BCR | | | | +------x------+ <-- 0.000 BPA=ARP <-- 0.3794 --> ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center