KUNM Site Information Form International GPS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : David A. Stowers Date Prepared : 1999-06-29 Report Type : UPDATE If Update: Previous Site Log : kunm9906.log Modified/Added Sections : (n.n,n.n,...) 1. Site Identification of the GNSS Monument Site Name : Kunming Four Character ID : KUNM Monument Inscription : none IERS DOMES Number : 21609M001 CDP Number : (A4) Monument Description : (PILLAR/BRASS PLATE/STEEL MAST/etc) Height of the Monument : (m) Monument Foundation : (STEEL RODS, CONCRETE BLOCK, ROOF, etc) Foundation Depth : (m) Marker Description : (CHISELLED CROSS/DIVOT/BRASS NAIL/etc) Date Installed : 1998-06-16 Geologic Characteristic : Conglomerate Bedrock Type : Sedimentary Bedrock Condition : (FRESH/JOINTED/WEATHERED) Fracture Spacing : (1-10 cm/11-50 cm/51-200 cm/over 200 cm) Fault zones nearby : (YES/NO/Name of the zone) Distance/activity : (multiple lines) Additional Information : (multiple lines) : Pillar is 2.8m above ground, 1.5m deep. : Rod set over pillar. 24 hrs data : collected at this site. 2. Site Location Information City or Town : Kunming State or Province : Yunnan Country : China Tectonic Plate : Eurasian Approximate Position (ITRF) X coordinate (m) : -1281255.52 Y coordinate (m) : 5640746.09 Z coordinate (m) : 2682880.08 Latitude (N is +) : +250144.40 Longitude (E is +) : +1024749.20 Elevation (m,ellips.) : 2023 Additional Information : (multiple lines) 3. GNSS Receiver Information 3.1 Receiver Type : ROGUE SNR-8000 Satellite System : (GPS/GLONASS/GPS+GLONASS) Serial Number : T134 Firmware Version : 3.2 link 3/9/1995 Elevation Cutoff Setting : (deg) Date Installed : 1998-06-16 Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : 3.2 Receiver Type : ROGUE SNR-8000 Satellite System : (GPS/GLONASS/GPS+GLONASS) Serial Number : T134 Firmware Version : 3.2.32.8 Elevation Cutoff Setting : (deg) Date Installed : 1999-05-21 Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS/GLONASS/GPS+GLONASS) Serial Number : (A5) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : AOAD/M_T Serial Number : 134 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.07927 Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : 0 Antenna Radome Type : Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : 1998-06-16 Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : Mount bolted to pillar with 3 expansion : bolts. 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.1 Tied Marker Name : KUN2 Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : Tied Marker DOMES Number : Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : dy (m) : dz (m) : Accuracy (mm) : Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : 1998-06-15 Additional Information : 24 hr data collected at this site. 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : dy (m) : dz (m) : Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information Date Removed : Date Installed : 7.1 Instrumentation Type : n/a Status : Effective Dates : Notes : 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation Date Removed : Date Installed : 8.1.1 Humidity Sensor Model : none Manufacturer : Serial Number : Data Sampling Interval : Accuracy (% rel h) : Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : Notes : 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) Date Removed : Date Installed : 8.2.1 Pressure Sensor Model : none Manufacturer : Serial Number : Data Sampling Interval : Accuracy : Height Diff to Ant : Calibration date : (CCYY-MM-DD) Effective Dates : Notes : 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) Date Removed : Date Installed : 8.3.1 Temp. Sensor Model : none Manufacturer : Serial Number : Data Sampling Interval : Accuracy : Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : Notes : 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) Date Removed : Date Installed : 8.4.1 Water Vapor Radiometer : none Manufacturer : Serial Number : Distance to Antenna : Height Diff to Ant : Calibration date : (CCYY-MM-DD) Effective Dates : Notes : 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.1 Other Instrumentation : 8.5.x Other Instrumentation : 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degredations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Yunnan Observatory Preferred Abbreviation : (A10) Mailing Address : Chinese Academy of Sciences : P.O Box 110 : Kunming, Yunnan : China 650011 Primary Contact Contact Name : Miao Yuanxing Telephone (primary) : 011-86-871-3912154 Telephone (secondary) : Fax : 011-86-871-3911845 E-mail : ymiao@public.km.yn.cn Secondary Contact Contact Name : Bao Monxian Telephone (primary) : 011-86-871-338-1245 Telephone (secondary) : Fax : 011-86-871-335-8437 E-mail : ynao@public.km.yn.cn Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : JPL Preferred Abbreviation : (A10) Mailing Address : 4800 Oak Grove Drive : Pasadena, CA : USA 91109 Primary Contact Contact Name : David A. Stowers Telephone (primary) : 818-354-7055 Telephone (secondary) : 818-354-2950 Fax : 818-393-4965 E-mail : dstowers@jpl.nasa.gov Secondary Contact Contact Name : Network Engineer/UNAVCO Telephone (primary) : 303-497-8000 Telephone (secondary) : Fax : 303-497-8028 E-mail : ruud or kfeaux @unavco.ucar.edu Additional Information : Oivind Ruud (x8030) or Karl Feaux (x8037) 13. More Information URL for More Information : www.unavco.ucar.edu/network Hardcopy on File Site Map : (Y or URL) Site Diagram : (Y or URL) Horizon Mask : (Y or URL) Monument Description : (Y or URL) Site Pictures : (Y or URL) Additional Information : (multiple lines) Antenna Graphics with Dimensions TurboRogue: AOAD/M_T ----- / + \ <-- 0.128 L2 | + | <-- 0.110 L1 +--------------------------------------------------+ <-- 0.102 TCR | | | | | | | | +-+--------------------------------------------------+-+ <-- 0.038 +-------------------+-------------+--------------------+ <-- 0.035 BCR | | =| | +------x------+ <-- 0.000 ARP <-- 0.381 --> ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center TCR: Top of Chokering BCR: Bottom of Chokering TGP: Top of Ground Plane BGP: Bottom of Ground Plane TPA: Top of Preamplifier BPA: Bottom of Preamplifier TOP: Top of Pole