JOZE Site Information Form (site log) International GNSS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Lech Kujawa, Tomasz Liwosz Date Prepared : 2009-11-13 Report Type : UPDATE If Update: Previous Site Log : joze_20090609.log Modified/Added Sections : 0, 1, 2, 3.1, 3.2, 6.1, 6.2, 7.1, 8.1.1, 8.1.2, : 8.2.1, 8.2.2, 8.3.1, 8.3.2, 9.3.1, 11, 13 1. Site Identification of the GNSS Monument Site Name : JOZEFOSLAW Four Character ID : JOZE Monument Inscription : stable geodynamical pillar IERS DOMES Number : 12204M001 CDP Number : (A4) Monument Description : Pillar Height of the Monument : 1.0 Monument Foundation : CONCRETE Foundation Depth : 2.5 Marker Description : forced centered plate Date Installed : 1993-08-03 Geologic Characteristic : clay Bedrock Type : SEDIMENTARY Bedrock Condition : (FRESH/JOINTED/WEATHERED) Fracture Spacing : (0 cm/1-10 cm/11-50 cm/51-200 cm/over 200 cm) Fault zones nearby : Teisseyre Distance/activity : (multiple lines) Additional Information : point of IGS, EUREF, EPOCH-92, CERGOP, : CERGOP2,geodyn. network EXTENDED SAGET : IERS DOMES Number by Altamimi, 22-NOV-93 2. Site Location Information City or Town : Jozefoslaw State or Province : Mazovian Country : Poland Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : 3664940.50 Y coordinate (m) : 1409153.59 Z coordinate (m) : 5009571.17 Latitude (N is +) : +520550.18 Longitude (E is +) : +0210153.52 Elevation (m,ellips.) : 141.4 Additional Information : Near Warsaw 3. GNSS Receiver Information 3.1 Receiver Type : TRIMBLE 4000SSE Satellite System : GPS Serial Number : 2090 Firmware Version : NP 7.19; SP 3.04 Elevation Cutoff Setting : 0 Date Installed : 1993-08-03 Date Removed : 2009-05-21T11:00Z Temperature Stabiliz. : 19 +/- 1 Additional Information : (multiple lines) 3.2 Receiver Type : TRIMBLE 4000SSI Satellite System : GPS Serial Number : 4002A27500 Firmware Version : 7.29 Elevation Cutoff Setting : 0 Date Installed : 2009-05-21T12:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : 19 +/- 1 Additional Information : (multiple lines) 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TRM14532.00 NONE Serial Number : 23525 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.1980 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 4.0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Trimble Antenna Cable Length : 30 Date Installed : 1993-08-08 Date Removed : CCYY-MM-DDThh:mmZ Additional Information : (multiple lines) 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : EXTERNAL RUBIDIUM Input Frequency : 10 Mhz Effective Dates : 1994-11-10/2005-06-30 Notes : TEMEX NEUCHATEL TIME SA : Frequency standard was out of order several : times during this period. 6.2 Standard Type : INTERNAL Input Frequency : (if external) Effective Dates : 2005-07-01/CCYY-MM-DD Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : GPS/GLONASS, GRAVITY Status : PERMANENT Effective Dates : 2001-01-01/CCYY-MM-DD Notes : gravity tidal station no. 0909 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : HPTL.3A (Vaisala) Manufacturer : NAVI Ltd.,Sporna 11, PL 61-709 POZNAN Serial Number : Data Sampling Interval : 1800 Accuracy (% rel h) : 1 Aspiration : UNASPIRATED Height Diff to Ant : 1 Calibration date : 2001-10-05 Effective Dates : 1997-01-01/2001-10-19 Notes : (multiple lines) 8.1.2 Humidity Sensor Model : LB-710RHMS Manufacturer : LAB-EL POLAND Serial Number : Data Sampling Interval : 900 Accuracy (% rel h) : 2 Aspiration : NATURAL Height Diff to Ant : 11.1 Calibration date : 2001-10-05 Effective Dates : 2001-10-20/CCYY-MM-DD Notes : (multiple lines) 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : HPTL.3A (Vaisala) Manufacturer : NAVI Ltd.,Sporna 11, PL 61-709 POZNAN Serial Number : Data Sampling Interval : 1800 Accuracy : 0.2 Height Diff to Ant : 1 Calibration date : 2001-10-05 Effective Dates : 1997-01-01/2001-10-19 Notes : (multiple lines) 8.2.2 Pressure Sensor Model : LB-716 Manufacturer : LAB-EL POLAND Serial Number : Data Sampling Interval : 900 Accuracy : 0.5 Height Diff to Ant : 2.5 Calibration date : 2001-10-05 Effective Dates : 2001-10-20/CCYY-MM-DD Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : HPTL.3A (Vaisala) Manufacturer : NAVI Ltd.,Sporna 11, PL 61-709 POZNAN Serial Number : Data Sampling Interval : 1800 Accuracy : 0.2 Aspiration : UNASPIRATED Height Diff to Ant : 10 Calibration date : 2001-10-05 Effective Dates : 1997-01-01/2001-10-19 Notes : (multiple lines) 8.3.2 Temp. Sensor Model : LB-710RHMS Manufacturer : LAB-EL POLAND Serial Number : Data Sampling Interval : 900 Accuracy : 0.2 Aspiration : NATURAL Height Diff to Ant : 11.1 Calibration date : 2001-10-05 Effective Dates : 2001-10-20/CCYY-MM-DD Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.1 Signal Obstructions : TREES/BUILDINGS Effective Dates : 1997-01-01/CCYY-MM-DD Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.1 Date : 2001-11-20/2002-03-01 Event : TREE CLEARING 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Department of Geodesy & Geodetic Astronomy : Warsaw University of Technology Preferred Abbreviation : WUT Mailing Address : Warsaw University of Technology : Poland, 00-661 Warsaw, 1 Politechniki Sq. Primary Contact Contact Name : Michal Kruczyk Telephone (primary) : +48 22 6214248 Telephone (secondary) : +48 22 2347754 Fax : +48 22 6214248 E-mail : kruczyk@gik.pw.edu.pl Secondary Contact Contact Name : Tomasz Liwosz Telephone (primary) : (48-22) 6214248 Telephone (secondary) : (48-22) 2347754 Fax : (48-22) 6214248 E-mail : tomasz.liwosz@gik.pw.edu.pl Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : (multiple lines) Preferred Abbreviation : (A10) Mailing Address : (multiple lines) Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : OLG Secondary Data Center : BKGI URL for More Information : http://www.gik.pw.edu.pl/ Hardcopy on File Site Map : X Site Diagram : X Horizon Mask : X Monument Description : X Site Pictures : X Additional Information : (multiple lines) Antenna Graphics with Dimensions TRM14532.00 4000ST L1/L2 Geodetic, Model 14532.00 ----+---- <-- 0.0780 L1 / + \ <-- 0.0680 L2 ++----------------+-----------------+-----------------++ <-- 0.0630 TGP ++---------------+-------------------+----------------++ <-- 0.0600 BGP | | | | | | +------x------+ <-- 0.0 BPA=ARP <-- 0.140 --> BPA <-- 0.155 --> TPA <-- 0.467 --> NOTCHES <-- 0.483 --> EDGE ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center TGP: Top of Ground Plane BGP: Bottom of Ground Plane BPA: Bottom of Preamplifier Trimble: TRM14532.00 ----+---- <-- 0.2710 L1 / + \ <-- 0.2690 L2 ++----------------+-----------------+-----------------++ <-- 0.2640 TGP ++---------------+-------------------+----------------++ <-- 0.2610 BGP | | | | | | | | +----------+---------+----------+ <-- 0.1980 ARP=BPA | | | Concrete Pillar |--+ <-- 0.0 <= Reference Point | | | | |--+ ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center