JOZ200POL Site Information Form (site log) International GNSS Service See Instructions at: ftp://igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Tomasz Liwosz Date Prepared : 2019-03-24 Report Type : UPDATE If Update: Previous Site Log : joz2_20130502.log Modified/Added Sections : 0, 1, 3.6, 3.7, 4.2, 4.3, 11, 13 1. Site Identification of the GNSS Monument Site Name : JOZEFOSLAW Four Character ID : JOZ2 Monument Inscription : Joze2 IERS DOMES Number : 12204M002 CDP Number : Monument Description : steel mast Height of the Monument : 1.5 m Monument Foundation : roof of building Foundation Depth : Marker Description : forced centered plate Date Installed : 2002-01-03T00:00Z Geologic Characteristic : CLAY Bedrock Type : SEDIMENTARY Bedrock Condition : JOINTED Fracture Spacing : over 200 cm Fault zones nearby : Teisseyre Distance/activity : Additional Information : point of IGS, EUREF 2. Site Location Information City or Town : Jozefoslaw State or Province : Mazovia Country : Poland Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : 3664881.000 Y coordinate (m) : 1409190.000 Z coordinate (m) : 5009618.000 Latitude (N is +) : +520552.19 Longitude (E is +) : +0210156.43 Elevation (m,ellips.) : 152.3 Additional Information : 3. GNSS Receiver Information 3.1 Receiver Type : ASHTECH Z18 Satellite System : GPS+GLO Serial Number : ZX199912127 Firmware Version : 0064 Elevation Cutoff Setting : 0 deg Date Installed : 2002-01-03T00:00Z Date Removed : 2008-03-14T10:00Z Temperature Stabiliz. : 19.0 +/- 1.0 Additional Information : 3.2 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355045 Firmware Version : 5.62/3.014 Elevation Cutoff Setting : 0 deg Date Installed : 2008-03-14T10:10Z Date Removed : 2009-05-06T18:00Z Temperature Stabiliz. : 19.0 +/- 1.0 Additional Information : 3.3 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355045 Firmware Version : 5.62/3.017 Elevation Cutoff Setting : 0 deg Date Installed : 2009-05-10T20:00Z Date Removed : 2010-05-01T10:26Z Temperature Stabiliz. : 19.0 +/- 1.0 Additional Information : 3.4 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355045 Firmware Version : 5.62/3.019 Elevation Cutoff Setting : 0 deg Date Installed : 2010-05-01T10:27Z Date Removed : 2011-05-26T14:50Z Temperature Stabiliz. : 19.0 +/- 1.0 Additional Information : 3.5 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355045 Firmware Version : 8.20/3.019 Elevation Cutoff Setting : 0 deg Date Installed : 2011-05-26T15:09Z Date Removed : 2013-05-02T11:20Z Temperature Stabiliz. : 19.0 +/- 1.0 Additional Information : 3.6 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355045 Firmware Version : 8.71/3.822 Elevation Cutoff Setting : 0 deg Date Installed : 2013-05-02T11:41Z Date Removed : 2019-03-22T12:31Z Temperature Stabiliz. : 19.0 +/- 1.0 Additional Information : 3.7 Receiver Type : TRIMBLE NETR9 Satellite System : GPS+GLO+GAL+BDS+QZSS Serial Number : 5541R50016 Firmware Version : 5.37 Elevation Cutoff Setting : 0 deg Date Installed : 2019-03-22T15:30Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : 21.0 +/- 1.0 Additional Information : 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : ASH701941.B SNOW Serial Number : CRL20004801 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 4 deg Antenna Radome Type : SNOW Radome Serial Number : Antenna Cable Type : N/A Antenna Cable Length : 10 m Date Installed : 2002-01-03T00:00Z Date Removed : 2008-03-14T10:00Z Additional Information : 4.2 Antenna Type : LEIAT504GG NONE Serial Number : 200300 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : N/A Antenna Cable Length : 10 m Date Installed : 2008-03-14T10:10Z Date Removed : 2019-03-22T12:31Z Additional Information : 4.3 Antenna Type : TRM59800.00 NONE Serial Number : 5516356133 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : TIMES MICROWAVE SYSTEMS LMR-400 Antenna Cable Length : 30 m Date Installed : 2019-03-22T15:30Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : Surge protector (Polyphaser DGXZ+15TFTF-A) : installed in antenna cable. : The cable consists of LMR-400 cable (30 m), : surge protector, and RG213 cable (2.5 m). 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.1 Tied Marker Name : JOZE Tied Marker Usage : EUREF/IGS Tied Marker CDP Number : Tied Marker DOMES Number : 12204M001 Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : -59.580 dy (m) : 36.731 dz (m) : 47.105 Accuracy (mm) : 1 mm Survey method : GPS TRIANGULATION Date Measured : 2001-10-10T00:00Z Additional Information : Data from permanent GPS observations 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : EXTERNAL RUBIDIUM Input Frequency : 10 MHz Effective Dates : 1994-11-10/2008-03-14 Notes : TEMEX NEUCHATEL TIME SA 6.2 Standard Type : INTERNAL Input Frequency : Effective Dates : 2008-03-14/CCYY-MM-DD Notes : 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : GPS, GRAVITY Status : PERMANENT Effective Dates : 1993-11-01/CCYY-MM-DD Notes : gravity tidal station no. 0909 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : LB-710RHMS Manufacturer : LAB-EL POLAND Serial Number : Data Sampling Interval : 900 sec Accuracy (% rel h) : 2 Aspiration : NATURAL Height Diff to Ant : 0 m Calibration date : 2001-10-05 Effective Dates : 2001-10-20/CCYY-MM-DD Notes : 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : LB-716 Manufacturer : LAB-EL POLAND Serial Number : Data Sampling Interval : 900 sec Accuracy : 0.5 hPa Height Diff to Ant : -9 m Calibration date : 2001-10-05 Effective Dates : 2001-10-20/CCYY-MM-DD Notes : 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : LB-710RHMS Manufacturer : LAB-EL POLAND Serial Number : Data Sampling Interval : 900 sec Accuracy : 0.2 deg C Aspiration : NATURAL Height Diff to Ant : 0 m Calibration date : 2001-10-05 Effective Dates : 2001-10-20/CCYY-MM-DD Notes : 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Warsaw University of Technology : Department of Geodesy and Geodetic Astronomy Preferred Abbreviation : WUT Mailing Address : pl. Politechniki 1 : 00-661 Warszawa : Poland Primary Contact Contact Name : Tomasz Liwosz Telephone (primary) : Telephone (secondary) : Fax : E-mail : tomasz.liwosz@pw.edu.pl Secondary Contact Contact Name : Michal Kruczyk Telephone (primary) : Telephone (secondary) : Fax : E-mail : michal.kruczyk@pw.edu.pl Additional Information : 12. Responsible Agency (if different from 11.) Agency : Preferred Abbreviation : Mailing Address : Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : 13. More Information Primary Data Center : BKG Secondary Data Center : BEV URL for More Information : http://www.gik.pw.edu.pl Hardcopy on File Site Map : X Site Diagram : X Horizon Mask : X Monument Description : X Site Pictures : X Additional Information : X Antenna Graphics with Dimensions TRM59800.00 ----- / \ | | +-------------------------------------------------+ <-- 0.1020 TCR | | | | | | | | +-+-------------------------------------------------+-+ <-- 0.0381 +-------------------+-------------+-------------------+ <-- 0.0350 BCR | | =| | +------x------+ <-- 0.0000 BPA=ARP RXC=NRP <-- 0.3810 -->