JOZ2 Site Information Form (site log) International GPS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Lech Kujawa Date Prepared : 2008-06-10 Report Type : UPDATE If Update: Previous Site Log : joz2_20080507.log Modified/Added Sections : 0, 3.2 1. Site Identification of the GNSS Monument Site Name : JOZEFOSLAW Four Character ID : JOZ2 Monument Inscription : Joze2 IERS DOMES Number : 12204M002 CDP Number : (A4) Monument Description : steel mast Height of the Monument : 1.5 m Monument Foundation : roof of building Foundation Depth : Marker Description : forced centered plate Date Installed : 1993-08-03 Geologic Characteristic : clay Bedrock Type : Bedrock Condition : Fracture Spacing : Fault zones nearby : Teisseyre Distance/activity : (multiple lines) Additional Information : point of IGS, EUREF, EPOCH-92, CERGOP, : CERGOP2,geodyn. network EXTENDED SAGET : IERS DOMES Number by Altamimi, 22-NOV-93 2. Site Location Information City or Town : Jozefoslaw State or Province : Country : Poland Tectonic Plate : Eurasian Approximate Position X coordinate (m) : 3664881 Y coordinate (m) : 1409190 Z coordinate (m) : 5009618 Latitude (N is +) : +520552.20 Longitude (E is +) : +0210156.45 Elevation (m,ellips.) : 00152.5 Additional Information : (multiple lines) 3. GNSS Receiver Information 3.1 Receiver Type : ASHTECH Z18 Satellite System : GPS+GLONASS Serial Number : ZX199912127 Firmware Version : 0064 Elevation Cutoff Setting : 0 Date Installed : 2002-01-03 Date Removed : 2008-03-14T10:00Z Temperature Stabiliz. : 19 Additional Information : 3.2 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLONASS Serial Number : 355045 Firmware Version : 5.62/3.014 Elevation Cutoff Setting : 0 Date Installed : 2008-03-14T10:10Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : 19 Additional Information : 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS/GLONASS/GPS+GLONASS) Serial Number : (A5) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : ASH701941.B SNOW Serial Number : CRL20004801 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 000.0000 Marker->ARP North Ecc(m) : 000.0000 Marker->ARP East Ecc(m) : 000.0000 Alignment from True N : 4.0 Antenna Radome Type : SNOW Radome Serial Number : Antenna Cable Type : N/A Antenna Cable Length : 10 Date Installed : 2002-01-03 Date Removed : 2008-03-14T10:00Z Additional Information : 4.2 Antenna Type : LEIAT504GG NONE Serial Number : 200300 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 000.0000 Marker->ARP North Ecc(m) : 000.0000 Marker->ARP East Ecc(m) : 000.0000 Alignment from True N : 0.0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : N/A Antenna Cable Length : 10 Date Installed : 2008-03-14T10:10Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.1 Tied Marker Name : JOZE Tied Marker Usage : EUREF/IGS Tied Marker CDP Number : Tied Marker DOMES Number : 12204M001 Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : -59.580 dy (m) : +36.731 dz (m) : +47.105 Accuracy (mm) : 1 Survey method : GPS TRIANGULATION Date Measured : 2001-10-10 Additional Information : Data from permanent GPS observations 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : RUBIDIUM Input Frequency : 10 Mhz Effective Dates : 1994-11-10/2008-03-14 Notes : TEMEX NEUCHATEL TIME SA 6.2 Standard Type : INTERNAL Input Frequency : (if external) Effective Dates : 2008-03-14/CCYY-MM-DD Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : GPS, GPS+GLONASS, GRAVITY Status : PERMANENT Effective Dates : 1993-11-01/2001-01-01 Notes : gravity tidal station no. 0909 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : HPTL.3A (Vaisala) Manufacturer : NAVI Ltd.,Sporna 11, PL 61-709 POZNAN Serial Number : Data Sampling Interval : 900 Accuracy (% rel h) : 1 Aspiration : NATURAL Height Diff to Ant : 1m Calibration date : 2001-10-05 Effective Dates : 1997-01-01/CCYY-MM-DD Notes : 8.1.2 Humidity Sensor Model : LB-710RHMS Manufacturer : LAB-EL POLAND Serial Number : Data Sampling Interval : 900 Accuracy (% rel h) : 2% Aspiration : NATURAL Height Diff to Ant : 0.3m Calibration date : 2001-10-05 Effective Dates : 2001-10-20/CCYY-MM-DD) Notes : (multiple lines) 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : HPTL.3A (Vaisala) Manufacturer : NAVI Ltd.,Sporna 11, PL 61-709 POZNAN Serial Number : Data Sampling Interval : 900 Accuracy : 0.2 hPa sigma Height Diff to Ant : 1m Calibration date : (2001-10-05) Effective Dates : 1997-01-01/CCYY-MM-DD Notes : 8.2.2 Pressure Sensor Model : LB-716 Manufacturer : LAB-EL POLAND Serial Number : Data Sampling Interval : 900 Accuracy : 0.5 hPa Height Diff to Ant : 0.3m Calibration date : 2001-10-05 Effective Dates : 2001-10-20/CCYY-MM-DD) Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : HPTL.3A (Vaisala) Manufacturer : NAVI Ltd.,Sporna 11, PL 61-709 POZNAN Serial Number : Data Sampling Interval : 900 Accuracy : +/- 0.2 deg C Aspiration : NATURAL Height Diff to Ant : (m) Calibration date : (2001-10-05) Effective Dates : 1997-01-01/CCYY-MM-DD Notes : 8.3.2 Temp. Sensor Model : LB-710RHMS Manufacturer : LAB-EL POLAND Serial Number : Data Sampling Interval : 900 Accuracy : +/- 0.2 deg C Aspiration : NATURAL Height Diff to Ant : 0.3m Calibration date : 2001-10-05 Effective Dates : 2001-10-20/CCYY-MM-DD) Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Institute of Geodesy & Geodetic Astronomy : Warsaw University of Technology Preferred Abbreviation : WUT Mailing Address : Warsaw University of Technology : Poland, 00-661 Warsaw, 1 Politechniki Sq. Primary Contact Contact Name : Lech Kujawa Telephone (primary) : (48-22) 6214248 Telephone (secondary) : (48-22) 6607754 Fax : (48-22) 6212448 E-mail : lk@gik.pw.edu.pl Secondary Contact Contact Name : Jerzy Rogowski Telephone (primary) : (48-22) 6228515 Telephone (secondary) : (48-22) 6607754 Fax : (48-22) 6210052 E-mail : jbr@gik.pw.edu.pl Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : Preferred Abbreviation : Mailing Address : Primary Contact : Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : BKGI Secondary Data Center : OLG URL for More Information : http://www.gik.pw.edu.pl Hardcopy on File Site Map : X Site Diagram : X Horizon Mask : X Monument Description : X Site Pictures : X Additional Information : avaiable after May 25 1997 Antenna Graphics with Dimensions LEIAT504GG +-------+ <-- 0.1393 / + \ | + | +-----------------+-------------+------------------+ <-- 0.1012 TCR | | | | | | | | +-+--------------------------------------------------+-+ +-------------------+-------------+--------------------+ <-- 0.0345 BCR | | | | +------x------+ <-- 0.0000 BPA=ARP <-- 0.3794 --> ARP: Antenna Reference Point BPA: Bottom of Preamplifier TCR: Top of Chokering BCR: Bottom of Chokering