JOZ2 Site Information Form (site log) International GPS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Lech Kujawa Date Prepared : 2002-09-25 Report Type : NEW If Update: Previous Site Log : Modified/Added Sections : 1. Site Identification of the GPS Monument Site Name : JOZEFOSLAW Four Character ID : JOZ2 Monument Inscription : IERS DOMES Number : 12204M002 CDP Number : (A4) Monument Description : steel mast Height of the Monument : 1.5 m Monument Foundation : roof of building Foundation Depth : Marker Description : forced centered plate Date Installed : 1993-08-03 Geologic Characteristic : clay Bedrock Type : Bedrock Condition : Fracture Spacing : Fault zones nearby : Teisseyre Distance/activity : (multiple lines) Additional Information : point of IGS, EUREF, EPOCH-92, CERGOP, : CERGOP2,geodyn. network EXTENDED SAGET : IERS DOMES Number by Altamimi, 22-NOV-93 2. Site Location Information City or Town : JOZEFOSLAW near WARSAW State or Province : Country : POLAND Tectonic Plate : Eurasian Approximate Position X coordinate (m) : 3664880 Y coordinate (m) : 1409190 Z coordinate (m) : 5009618 Latitude (N is +) : +520552.20 Longitude (E is +) : +0210156.46 Elevation (m,ellips.) : 00152.5 Additional Information : (multiple lines) 3. GNSS Receiver Information 3.1 Receiver Type : ASHTECH Z18 Satellite System : GPS+GLONASS Serial Number : ZX199912127 Firmware Version : 0064 Elevation Cutoff Setting : 0 Date Installed : 2002-01-03 Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : 19 Additional Information : (multiple lines) 4. GPS Antenna Information 4.1 Antenna Type : ASH701941.B SNOW Serial Number : CRL20004801 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 000.0000 Marker->ARP North Ecc (m): 000.0000 Marker->ARP East Ecc (m) : 000.0000 Alignment from True N : 4.0 Antenna Radome Type : SNOW Radome Serial Number : Antenna Cable Type : Antenna Cable Lenght : 18 Date Installed : 2002-01-03 Date Removed : CCYY-MM-DDThh:mmZ Additional Information : 5. Surveyed Local Ties 5.1 Tied Marker Name : JOZE Tied Marker Usage : EUREF/IGS Tied Marker CDP Number : Tied Marker DOMES Number : 12204M001 Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : -59.580 dy (m) : +36.731 dz (m) : +47.105 Accuracy (mm) : 1 Survey method : GPS OBSERVATIONS Date Measured : 2001-10-10 Additional Information : Data from permanent GPS observations 6. Frequency Standard 6.1 Standard Type : RUBIDIUM Frequency : 10 Mhz Effective Dates : 1994-11-10/CCYY-MM-DD Notes : TEMEX NEUCHATEL TIME SA 7. Collocation Information 7.1 Instrumentation Type : GPS, GPS+GLONASS, GRAVITY Status : PERMANENT Effective Dates : 2001-01-01/1993-11-01 Notes : gravity tidal station no. 0909 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : HPTL.3A (Vaisala) Manufacturer : NAVI Ltd.,Sporna 11, PL 61-709 POZNAN Serial Number : Data Sampling Interval : 900 Accuracy (% rel h) : 1 Aspiration : NATURAL Height Diff to Ant : 1m Calibration date : 2001-10-05 Effective Dates : 1997-01-01/CCYY-MM-DD Notes : 8.1.2 Humidity Sensor Model : LB-710RHMS Manufacturer : LAB-EL POLAND Serial Number : Data Sampling Interval : 900 Accuracy (% rel h) : 2% Aspiration : NATURAL Height Diff to Ant : 0.3m Calibration date : 2001-10-05 Effective Dates : 2001-10-20/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : HPTL.3A (Vaisala) Manufacturer : NAVI Ltd.,Sporna 11, PL 61-709 POZNAN Serial Number : Data Sampling Interval : 900 Accuracy : 0.2 hPa sigma Height Diff to Ant : 1m Calibration date : (2001-10-05) Effective Dates : 1997-01-01/CCYY-MM-DD Notes : 8.2.2 Pressure Sensor Model : LB-716 Manufacturer : LAB-EL POLAND Serial Number : Data Sampling Interval : 900 Accuracy : 0.5 hPa Height Diff to Ant : 0.3m Calibration date : 2001-10-05 Effective Dates : 2001-10-20/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : HPTL.3A (Vaisala) Manufacturer : NAVI Ltd.,Sporna 11, PL 61-709 POZNAN Serial Number : Data Sampling Interval : 900 Accuracy : +/- 0.2 deg C Aspiration : NATURAL Height Diff to Ant : (m) Calibration date : (2001-10-05) Effective Dates : 1997-01-01/CCYY-MM-DD Notes : 8.3.2 Temp. Sensor Model : LB-710RHMS Manufacturer : LAB-EL POLAND Serial Number : Data Sampling Interval : 900 Accuracy : +/- 0.2 deg C Aspiration : NATURAL Height Diff to Ant : 0.3m Calibration date : 2001-10-05 Effective Dates : 2001-10-20/CCYY-MM-DD) Notes : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : NO Observed Degredations : NO Effective Dates : 2001-10-01/2002-09-20) Additional Information : (multiple lines) 9.2.x Multipath Sources : NO Effective Dates : 2001-10-01/2002-09-20 Additional Information : (multiple lines) 9.3.x Signal Obstructions : NO Effective Dates : 2001-10-01/2002-09-20) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : Event : 11. On-Site, Point of Contact Agency Information Agency : Institute of Geodesy & Geodetic Astronomy : Warsaw University of Technology Preferred Abbreviation : (A10) Mailing Address : Warsaw University of Technology : Poland, 00-661 Warsaw, 1 Politechniki Sq. Primary Contact Contact Name : Lech Kujawa Telephone (primary) : (48-22) 6214248 Telephone (secondary) : (48-22) 6607754 Fax : (48-22) 6212448 E-mail : lk@gik.pw.edu.pl Secondary Contact Contact Name : Jerzy Rogowski Telephone (primary) : (48-22) 6228515 Telephone (secondary) : (48-22) 6607754 Fax : (48-22) 6210052 E-mail : jbr@gik.pw.edu.pl Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : Preferred Abbreviation : Mailing Address : Primary Contact : Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : BKG Frankfurt Secondary Data Center : OLG Graz URL for More Information : http://www.gik.pw.edu.pl/ Hardcopy on File Site Map : X Site Diagram : X Horizon Mask : X Monument Description : X Site Pictures : X Additional Information : avaiable after May 25 1997 Antenna Graphics with Dimensions ASH701941.B SNOW . --- . <-- 0.420 . . / \ / \ . . / \ / \ . . / \ / \ . . / \ . . / +---------+ \ / / + \ \ -- 0.1267 L2 / | + | \ -- 0.1080 L1 +-----------------+-------------+------------------+ -- 0.1008 TCR | | | | | | | | +-+--------------------------------------------------+-+ -- 0.0378 +-------------------+-------------+--------------------+ -- 0.0348 BCR | | | | +------x------+ -- 0.0000 BPA=ARP -- 0.3794 -- ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center TCR: Top of Chokering BCR: Bottom of Chokering TPA: Top of Preamplifier BPA: Bottom of Preamplifier