JOG200IDN Site Information Form (site log) International GNSS Service See Instructions at: https://files.igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : markus.bradke@gfz-potsdam.de Date Prepared : 2022-04-28 Report Type : UPDATE If Update: Previous Site Log : jog2_20211028.log Modified/Added Sections : 0, 3.12, 3.13 1. Site Identification of the GNSS Monument Site Name : YogYakarta Four Character ID : JOG2 Monument Inscription : IERS DOMES Number : 23109M002 CDP Number : Monument Description : PILLAR Height of the Monument : 1.51 m Monument Foundation : ROOF Foundation Depth : 4.00 m Marker Description : BRASS NAIL Date Installed : 2004-12-08T04:00Z Geologic Characteristic : Bedrock Type : YOUNG VOLCANIC SAND Bedrock Condition : OLD VOLCANIC SAND Fracture Spacing : 1-10 cm Fault zones nearby : Opak and Progo Fault Distance/activity : 15 km to Opak fault, 15 km to Progo fault : south 25 km from Merapi very active : caldera (4 yearly eruption) Additional Information : Monument Foundation attached to the building : pillar on the 3rd floor/11.25m from the ground 2. Site Location Information City or Town : Yogyakarta State or Province : Daerah Instimewa Yogyakarta Country : Indonesia Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : -2200208.0871 Y coordinate (m) : 5924895.6273 Z coordinate (m) : -855929.2334 Latitude (N is +) : -074549.73 Longitude (E is +) : +1102220.87 Elevation (m,ellips.) : 174.4 Additional Information : 3. GNSS Receiver Information 3.1 Receiver Type : AOA BENCHMARK ACT Satellite System : GPS Serial Number : 2002 Firmware Version : 3.3.32.2N Elevation Cutoff Setting : 0.5 deg Date Installed : 2004-12-08T04:00Z Date Removed : 2011-05-03T05:00Z Temperature Stabiliz. : none Additional Information : 3.2 Receiver Type : SEPT POLARX2 Satellite System : GPS Serial Number : 1260 Firmware Version : 2.7.0 Elevation Cutoff Setting : 0 deg Date Installed : 2011-05-03T05:00Z Date Removed : 2011-12-03T00:00Z Temperature Stabiliz. : none Additional Information : 3.3 Receiver Type : TPS NETG3 Satellite System : GPS+GLO Serial Number : 01153 Firmware Version : 3.4p2 Elevation Cutoff Setting : 0 deg Date Installed : 2011-12-03T00:00Z Date Removed : 2013-02-05T23:59Z Temperature Stabiliz. : none Additional Information : 3.4 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL Serial Number : 212 Firmware Version : 3.4.7 Elevation Cutoff Setting : 0 deg Date Installed : 2013-02-06T00:00Z Date Removed : 2016-04-20T08:17Z Temperature Stabiliz. : Additional Information : 3.5 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL Serial Number : 212 Firmware Version : 3.5.12 Elevation Cutoff Setting : 0 deg Date Installed : 2016-04-20T08:18Z Date Removed : 2016-10-25T12:49Z Temperature Stabiliz. : Additional Information : 3.6 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL Serial Number : 212 Firmware Version : 3.6.7 Elevation Cutoff Setting : 0 deg Date Installed : 2016-10-25T12:49Z Date Removed : 2016-11-09T09:19Z Temperature Stabiliz. : Additional Information : enables tracking of E01/E02 3.7 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL+QZSS Serial Number : 212 Firmware Version : 3.6.7 Elevation Cutoff Setting : 0 deg Date Installed : 2016-11-09T09:19Z Date Removed : 2018-07-09T14:05Z Temperature Stabiliz. : Additional Information : QZSS option activated 3.8 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL+QZSS Serial Number : 212 Firmware Version : 3.7.3P1 Elevation Cutoff Setting : 0 deg Date Installed : 2018-07-09T14:06Z Date Removed : 2018-09-12T10:35Z Temperature Stabiliz. : Additional Information : 3.9 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL+QZSS Serial Number : 212 Firmware Version : 3.7.4b0-193-7438 Elevation Cutoff Setting : 0 deg Date Installed : 2018-09-12T10:35Z Date Removed : 2019-02-19T14:51Z Temperature Stabiliz. : Additional Information : enables tracking of E31 3.10 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL+QZSS Serial Number : 212 Firmware Version : 3.7.5p1 Elevation Cutoff Setting : 0 deg Date Installed : 2019-02-19T14:52Z Date Removed : 2020-06-15T07:25Z Temperature Stabiliz. : Additional Information : Board revision TRE_G3TH_5 3.11 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL+QZSS Serial Number : 212 Firmware Version : 3.7.9 Elevation Cutoff Setting : 0 deg Date Installed : 2020-06-15T07:26Z Date Removed : 2020-11-11T12:38Z Temperature Stabiliz. : Additional Information : Board revision TRE_G3TH_5 3.12 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL+QZSS Serial Number : 212 Firmware Version : 3.7.10 Elevation Cutoff Setting : 0 deg Date Installed : 2020-11-11T12:39Z Date Removed : 2022-04-28T09:13Z Temperature Stabiliz. : Additional Information : Board revision TRE_G3TH_5 3.13 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL+QZSS Serial Number : 212 Firmware Version : 4.2.00-211012 Elevation Cutoff Setting : 0 deg Date Installed : 2022-04-28T09:14Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : Additional Information : Board revision TRE_G3TH_5 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : AOAD/M_T NONE Serial Number : 384 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0480 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Antenna Cable Length : 30.00 m Date Installed : 2004-12-08T04:00Z Date Removed : 2011-05-03T05:00Z Additional Information : 4.2 Antenna Type : TPSCR3_GGD NONE Serial Number : 2170502 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.1206 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Antenna Cable Length : Date Installed : 2011-05-03T05:00Z Date Removed : 2011-12-03T00:00Z Additional Information : 4.3 Antenna Type : TPSCR.G3 NONE Serial Number : 383-0153 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.1206 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Antenna Cable Length : Date Installed : 2011-12-03T00:00Z Date Removed : 2013-02-05T23:59Z Additional Information : 4.4 Antenna Type : JAV_RINGANT_G3T NONE Serial Number : 323 Antenna Reference Point : BAM Marker->ARP Up Ecc. (m) : 0.1206 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Ecoflex 10 Antenna Cable Length : 25.00 m Date Installed : 2013-02-06T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : Effective Dates : 2004-12-08/CCYY-MM-DD Notes : 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : HMP45A-P Manufacturer : Vaisala Serial Number : B3110015 Data Sampling Interval : 300 sec Accuracy (% rel h) : 1.5 Aspiration : NATURAL Height Diff to Ant : -0.80 m Calibration date : 2012-09-03 Effective Dates : 2013-02-06/CCYY-MM-DD Notes : The humidity sensor is part of a Vaisala : PTU200 meteo station 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : PTU200 Manufacturer : Vaisala Serial Number : B3110015 Data Sampling Interval : 300 sec Accuracy : 0.1 hPa Height Diff to Ant : -3.80 m Calibration date : 2012-09-03 Effective Dates : 2013-02-06/CCYY-MM-DD Notes : The pressure sensor is part of a Vaisala : PTU200 meteo station 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : HMP45A-P Manufacturer : Vaisala Serial Number : B3110015 Data Sampling Interval : 300 sec Accuracy : 0.1 deg C Aspiration : NATURAL Height Diff to Ant : -0.80 m Calibration date : 2012-09-03 Effective Dates : 2013-02-06/CCYY-MM-DD Notes : The temperature sensor is part of a Vaisala : PTU200 meteo station 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Universitas Gadjah Mada : Fakultas Teknik Preferred Abbreviation : GMU Mailing Address : Jl. Grafica 2 : Yogyakarta : Indonesia Primary Contact Contact Name : GFZ Network Operator Telephone (primary) : (+49)-331-2881746 Telephone (secondary) : Fax : E-mail : gnss@gfz-potsdam.de Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : 12. Responsible Agency (if different from 11.) Agency : Helmholtz Centre Potsdam : GFZ German Research Centre for Geosciences : Geodesy Preferred Abbreviation : GFZ Mailing Address : Telegrafenberg A17 : D-14473 Potsdam : Germany Primary Contact Contact Name : GFZ Network Operator Telephone (primary) : (+49)-331-2881746 Telephone (secondary) : Fax : E-mail : gnss@gfz-potsdam.de Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : 13. More Information Primary Data Center : CDDIS Secondary Data Center : IGN URL for More Information : https://gnss.gfz-potsdam.de Hardcopy on File Site Map : Site Diagram : Horizon Mask : Monument Description : Site Pictures : Y Additional Information : Antenna Graphics with Dimensions JAV_RINGANT_G3T --------- <-- 0.0614 / \ / \ +-------------------------------------------------+ <-- 0.0410 TCR | | | +-------------------+ | | | \ / | | | | \ / | | | | +--x--+ | | <-- 0.0000 BAM=ARP +--------------+-------------------+--------------+ <-- -0.0260 BCR RXC=NRP <-- 0.3260 --> TPSCR.G3 +-------+ / \ | | +-----------------+-------------+-----------------+ <-- 0.1015 TCR | | | | | | | | +-+-------------------------------------------------+-+ +-------------------+-------------+-------------------+ <-- 0.0345 BCR | | | | +------x------+ <-- 0.0000 BPA=ARP NOM=NRP <-- 0.1190 --> <-- 0.3800 --> TPSCR3_GGD --------- / \ | | +-------------------------------------------------+ <-- 0.0710 TCR | | | | | | | | +-----------------+-------------+-----------------+ <-- 0.0030 BCR +-----x-----+ <-- 0.0000 BPA=ARP NOM=NRP <-- 0.3260 --> AOAD/M_T ----- / \ | | +-------------------------------------------------+ <-- 0.1020 TCR | | | | | | | | +-+-------------------------------------------------+-+ <-- 0.0380 +-------------------+-------------+-------------------+ <-- 0.0350 BCR | | =| | +------x------+ <-- 0.0000 BPA=ARP RXC=NRP <-- 0.3810 -->