HARV00USA Site Information Form (site log) International GNSS Service See Instructions at: ftp://igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Tatevik Shakhbandaryan Date Prepared : 2019-05-31 Report Type : UPDATE If Update: Previous Site Log : harv_20181015.log Modified/Added Sections : 3.17,3.18 1. Site Identification of the GNSS Monument Site Name : Harvest Oil Platform Four Character ID : HARV Monument Inscription : Harvest GPS Pier IERS DOMES Number : 40420M101 CDP Number : Monument Description : STEEL PILLAR on Oil Platform Height of the Monument : Monument Foundation : Foundation Depth : Marker Description : Date Installed : 1992-06-07T00:00Z Geologic Characteristic : Bedrock Type : Bedrock Condition : Fracture Spacing : Fault zones nearby : Distance/activity : Additional Information : Geological Province : Local Geology : Geological information from "NASA Space Geodesy : Program : Technical Memorandum 4482, March 1993, p582. 2. Site Location Information City or Town : Vandenberg AFB State or Province : California Country : United States of America Tectonic Plate : PACIFIC Approximate Position (ITRF) X coordinate (m) : -2686069.7450 Y coordinate (m) : -4527083.8121 Z coordinate (m) : 3589502.6050 Latitude (N is +) : +342809.8478 Longitude (E is +) : -1204055.4476 Elevation (m,ellips.) : 14.9662 Additional Information : 15 Km SW of Vandenberg AFB : Latitude, Longitude and Elevation derived from : "IERS Technical Note 20, Results and Analysis : of the ITRF94" March 1996; Table 7 "ITRF94 : Class C Station Coordinates at Epoch 1993.0", : pT76. : This is a custom mount bolted to the Harvest : Oil Platform located off the coast of Santa : Barbara, California. : Coordinates were updated 2012-03-07 using : GIPSY and data from 2012-02-18 until : 2012-03-07; ITRF08 3. GNSS Receiver Information 3.1 Receiver Type : ROGUE SNR-8000 Satellite System : GPS Serial Number : T101 Firmware Version : 1.4 Elevation Cutoff Setting : Date Installed : 1992-06-17T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : Additional Information : 3.2 Receiver Type : ROGUE SNR-8000 Satellite System : GPS Serial Number : T101 Firmware Version : 1.41-7/25/92 Elevation Cutoff Setting : Date Installed : 1992-06-26T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : Additional Information : 3.3 Receiver Type : ROGUE SNR-8000 Satellite System : GPS Serial Number : T101 Firmware Version : 2.0-8/27/92 Elevation Cutoff Setting : Date Installed : 1992-07-30T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : Additional Information : 3.4 Receiver Type : ROGUE SNR-8000 Satellite System : GPS Serial Number : T101 Firmware Version : 2.2-9/22/92 Elevation Cutoff Setting : Date Installed : 1992-09-23T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : Additional Information : 3.5 Receiver Type : ROGUE SNR-8000 Satellite System : GPS Serial Number : T101 Firmware Version : 2.5-10/23/92 Elevation Cutoff Setting : Date Installed : 1992-10-29T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : Additional Information : 3.6 Receiver Type : ROGUE SNR-8000 Satellite System : GPS Serial Number : T101 Firmware Version : 2.6-93/01/12 Elevation Cutoff Setting : Date Installed : 1993-01-29T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : Additional Information : 3.7 Receiver Type : ROGUE SNR-8000 Satellite System : GPS Serial Number : T101 Firmware Version : 2.8-93/05/25 Elevation Cutoff Setting : Date Installed : 1993-06-07T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : Additional Information : 3.8 Receiver Type : ROGUE SNR-8000 Satellite System : GPS Serial Number : T101 Firmware Version : 2.8-93/06/08 Elevation Cutoff Setting : Date Installed : 1993-06-30T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : Additional Information : 3.9 Receiver Type : ROGUE SNR-8000 Satellite System : GPS Serial Number : T101 Firmware Version : 3.0 10/10/94 17:00:54 Elevation Cutoff Setting : Date Installed : 1994-11-19T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : Additional Information : 3.10 Receiver Type : ROGUE SNR-8000 Satellite System : GPS Serial Number : T101 Firmware Version : 3.2 link 03/09/95 Elevation Cutoff Setting : Date Installed : 1995-05-22T17:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : Additional Information : 3.11 Receiver Type : AOA BENCHMARK ACT Satellite System : GPS Serial Number : 1115 Firmware Version : 3.3.32.2 Elevation Cutoff Setting : Date Installed : 1999-07-27T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : Additional Information : 3.12 Receiver Type : AOA SNR-8000 ACT Satellite System : GPS Serial Number : T389 Firmware Version : 3.3.32.2 Elevation Cutoff Setting : Date Installed : 1999-09-10T00:00Z Date Removed : 2002-03-16T20:45Z Temperature Stabiliz. : Additional Information : 3.13 Receiver Type : AOA SNR-8000 ACT Satellite System : GPS Serial Number : T389 Firmware Version : 3.3.32.5 Elevation Cutoff Setting : Date Installed : 2002-03-16T21:49Z Date Removed : 2011-11-01T19:59Z Temperature Stabiliz. : Additional Information : firware update 3.14 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO Serial Number : 00848 Firmware Version : 3.3.5 Elevation Cutoff Setting : 4 deg Date Installed : 2012-02-18T00:09Z Date Removed : 2014-10-02T16:14Z Temperature Stabiliz. : Additional Information : Turbo Rogue failed, installed Javad Delta 3.15 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO Serial Number : 00848 Firmware Version : 3.5.7b0 Elevation Cutoff Setting : 0 deg Date Installed : 2014-10-02T16:15Z Date Removed : 2016-04-14T18:10Z Temperature Stabiliz. : Additional Information : 3.16 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO Serial Number : 00848 Firmware Version : 3.6.4 Elevation Cutoff Setting : 0 deg Date Installed : 2016-04-14T18:32Z Date Removed : 2018-10-09T17:45Z Temperature Stabiliz. : Additional Information : SBAS, QZSS turned off : L1 center frq set to 1573 3.17 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL Serial Number : 00848 Firmware Version : 3.7.2 Elevation Cutoff Setting : 0 deg Date Installed : 2018-10-09T19:30Z Date Removed : 2019-05-29T00:43Z Temperature Stabiliz. : Additional Information : SBAS off : L1 center frq set to 1573 3.18 Receiver Type : JAVAD TRE_G3TH DELTA Satellite System : GPS+GLO+GAL Serial Number : 00848 Firmware Version : 3.7.6 Elevation Cutoff Setting : 0 deg Date Installed : 2019-05-29T00:43Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : Additional Information : L1 center frq set to 1573 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : AOAD/M_T JPLA Serial Number : 101 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.1000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : Antenna Radome Type : JPLA Radome Serial Number : Antenna Cable Type : Antenna Cable Length : Date Installed : 1992-06-17T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : Effective Dates : 1996-06-17/2015-08-13 Notes : "Effective End Date" may be earlier than the : date specified. Until we find the exact date : we'll go with the earliest date for which we : have a record of the switch. 6.2 Standard Type : EXTERNAL Input Frequency : 10 MHz Effective Dates : 2015-08-13/CCYY-MM-DD Notes : "Effective Start Date" may be earlier than the : date specified. Until we find the exact date : we'll go with the earliest date for which we : have a record of the switch. 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : MET3 Manufacturer : Paroscientific Serial Number : Data Sampling Interval : 1 min sec Accuracy (% rel h) : 2 Aspiration : Height Diff to Ant : -24.8 m Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : 8.1.2 Humidity Sensor Model : MET4 Manufacturer : Paroscientific Serial Number : 77849 Data Sampling Interval : 60 second sec Accuracy (% rel h) : 2 Aspiration : Height Diff to Ant : -24.8 m Calibration date : (CCYY-MM-DD) Effective Dates : 2010-02-09/CCYY-MM-DD Notes : 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : MET3 Manufacturer : Paroscientific Serial Number : Data Sampling Interval : 1 min sec Accuracy : 0.08 hPa Height Diff to Ant : -24.8 m Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : 8.2.2 Pressure Sensor Model : MET4 Manufacturer : Paroscientific Serial Number : 77849 Data Sampling Interval : 60 second sec Accuracy : 0.08 hPa Height Diff to Ant : -24.8 m Calibration date : (CCYY-MM-DD) Effective Dates : 2010-02-09/CCYY-MM-DD Notes : 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : MET3 Manufacturer : Paroscientific Serial Number : Data Sampling Interval : 1 min sec Accuracy : 0.5 deg C Aspiration : Height Diff to Ant : -24.8 m Calibration date : Effective Dates : Notes : 8.3.2 Temp. Sensor Model : MET4 Manufacturer : Paroscientific Serial Number : 77849 Data Sampling Interval : 60 second sec Accuracy : 0.5 deg C Aspiration : Height Diff to Ant : -24.8 m Calibration date : Effective Dates : 2010-02-09/CCYY-MM-DD Notes : 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Jet Propulsion Laboratory Preferred Abbreviation : JPL Mailing Address : 4800 Oak Grove Drive : Pasadena, CA 91109 USA Primary Contact Contact Name : David A. Stowers Telephone (primary) : 1-818-354-7055 Telephone (secondary) : Fax : 1-818-393-4965 E-mail : dstowers@jpl.nasa.gov Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : 12. Responsible Agency (if different from 11.) Agency : Preferred Abbreviation : Mailing Address : Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : 13. More Information Primary Data Center : JPL Secondary Data Center : CDDIS URL for More Information : Hardcopy on File Site Map : Site Diagram : Horizon Mask : Monument Description : Site Pictures : Additional Information : Antenna Graphics with Dimensions TURBOROGUE: DORNE MARGOLIN T ----- / + \ <-- 0.128 L2 | + | <-- 0.110 L1 +--------------------------------------------------+ <-- 0.102 TCR | | | | | | | | +-+--------------------------------------------------+-+ <-- 0.038 +-------------------+-------------+--------------------+ <-- 0.035 BCR | | =| | +------x------+ <-- 0.000 BPA=ARP <-- 0.381 --> ARP: Antenna Reference Point BPA: Bottom of Preamplifier L1 : L1 Phase Center L2 : L2 Phase Center TCR: Top of Chokering BCR: Bottom of Chokering