GENO Site Information Form (site log) International GNSS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Giuseppe Colucci Date Prepared : 2014-03-03 Report Type : UPDATE If Update: Previous Site Log : geno_20130527.log Modified/Added Sections : 4.1 1. Site Identification of the GNSS Monument Site Name : Genova - Istituto Idrografico della Marina Four Character ID : GENO Monument Inscription : Stable pillar on the roof IERS DOMES Number : 12712M002 CDP Number : (A4) Monument Description : PILLAR Height of the Monument : 1.2 m Monument Foundation : CONCRETE BLOCK Foundation Depth : (m) Marker Description : CHISELLED CROSS Date Installed : 2001-08-22 Geologic Characteristic : BEDROCK Bedrock Type : SEDIMENTARY Bedrock Condition : (FRESH/JOINTED/WEATHERED) Fracture Spacing : (0 cm/1-10 cm/11-50 cm/51-200 cm/over 200 cm) Fault zones nearby : (YES/NO/Name of the zone) Distance/activity : (multiple lines) Additional Information : (multiple lines) 2. Site Location Information City or Town : Genova State or Province : LIGURIA Country : Italy Tectonic Plate : EURASIAN Approximate Position (ITRF) X coordinate (m) : 4507890.2717 Y coordinate (m) : 707618.9744 Z coordinate (m) : 4441603.0081 Latitude (N is +) : +442509.84 Longitude (E is +) : +0085515.96 Elevation (m,ellips.) : 137.0 Additional Information : (multiple lines) 3. GNSS Receiver Information 3.1 Receiver Type : TRIMBLE 4000SSI Satellite System : GPS Serial Number : 21512 Firmware Version : 7.29 Elevation Cutoff Setting : 15 deg Date Installed : 1998-07-23 Date Removed : 2001-08-22 Temperature Stabiliz. : 20 +/- 5 Additional Information : (multiple lines) 3.2 Receiver Type : TRIMBLE 4000SSI Satellite System : GPS Serial Number : 32811 Firmware Version : Nav 7.19 Sig 3.04 Elevation Cutoff Setting : 5 deg Date Installed : 2001-08-22 Date Removed : 2002-08-12 Temperature Stabiliz. : 20 +/- 5 Additional Information : (multiple lines) 3.3 Receiver Type : TRIMBLE 4000SSI Satellite System : GPS Serial Number : 32257 Firmware Version : Nav 7.19 Sig 3.04 Elevation Cutoff Setting : 5 deg Date Installed : 2002-08-13 Date Removed : 2013-05-21T10:00Z Temperature Stabiliz. : 20 +/- 5 Additional Information : (multiple lines) 3.4 Receiver Type : TRIMBLE 4700 Satellite System : GPS Serial Number : 220203888 Firmware Version : Nav 1.20 Sig 0.00 Elevation Cutoff Setting : 5 deg Date Installed : 2013-05-21T14:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : (deg C) +/- (deg C) Additional Information : (multiple lines) 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TRM29659.00 NONE Serial Number : 11730 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : RG214 Antenna Cable Length : 30 m Date Installed : 1998-07-23 Date Removed : CCYY-MM-DDThh:mmZ Additional Information : On Feb 27, 2014 a cable connector was replaced : by a new one 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : (if external) Effective Dates : 1998-07-23/CCYY-MM-DD Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : e-geos S.p.A. - una società ASI/Telespazio Preferred Abbreviation : TPZ Mailing Address : P.O.BOX OPEN - 75100 Matera, ITALY Primary Contact Contact Name : G. Colucci Telephone (primary) : ++39.0835.377574 Telephone (secondary) : Fax : E-mail : giuseppe.colucci@e-geos.it Secondary Contact Contact Name : R. Faccia, F. Ambrico Telephone (primary) : ++39.0835.377540 Telephone (secondary) : Fax : E-mail : gpsgeo@hp835.mt.asi.it Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : Agenzia Spaziale Italiana Preferred Abbreviation : ASI Mailing Address : P.O.BOX OPEN - 75100 Matera, ITALY Primary Contact Contact Name : Dott. Giuseppe Bianco Telephone (primary) : ++39.0835.377509 Telephone (secondary) : Fax : E-mail : giuseppe.bianco@asi.it Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : ASI Secondary Data Center : BKGI URL for More Information : http://geodaf.mt.asi.it/html/gps/info.html Hardcopy on File Site Map : (Y or URL) Site Diagram : (Y or URL) Horizon Mask : (Y or URL) Monument Description : (Y or URL) Site Pictures : (Y or URL) Additional Information : (multiple lines) Antenna Graphics with Dimensions TRM29659.00 Trimble L1/L2 Dorne Margolin element with chokerings Model 29659.00 ----- / + \ <-- 0.1280 L2 | + | <-- 0.1100 L1 +--------------------------------------------------+ <-- 0.1020 TCR | | | | | | | | +----------------------------------------------------+ <-- 0.0380 +------------------+-------------+-------------------+ <-- 0.0350 BCR | | | | +------x------+ <-- 0.0000 BPA ARP: Antenna Reference Point