FUNC00PRT Site Information Form (site log) International GNSS Service See Instructions at: ftp://igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Ana Carla Bernardes Date Prepared : 2020-10-07 Report Type : UPDATE If Update: Previous Site Log : func_20191212.log Modified/Added Sections : 10.1 1. Site Identification of the GNSS Monument Site Name : Funchal Four Character ID : FUNC Monument Inscription : None IERS DOMES Number : 13911S001 CDP Number : Monument Description : STEEL MAST Height of the Monument : 8 m Monument Foundation : ROOF Foundation Depth : Marker Description : Date Installed : 2006-07-21T00:00Z Geologic Characteristic : BASALT LAVA Bedrock Type : IGNEOUS Bedrock Condition : Fracture Spacing : Fault zones nearby : NO Distance/activity : Additional Information : Portuguese Permanent GNSS Network (ReNEP) : The GPS station is located on the terrace of : an old building, supported by a metal structure : The substract is composed by basalt lava flows : inclined to south.The flow belongs to the more : recent unit vulcano-stratigraphic from Madeira : Island : (between 1 to 1.5 million years until now) 2. Site Location Information City or Town : Funchal State or Province : Madeira Island-Madeira Country : Portugal Tectonic Plate : AFRICAN Approximate Position (ITRF) X coordinate (m) : 5143339.430 Y coordinate (m) : -1563412.870 Z coordinate (m) : 3421191.440 Latitude (N is +) : +323852.61 Longitude (E is +) : -0165427.42 Elevation (m,ellips.) : 78.5 Additional Information : ITRF93 3. GNSS Receiver Information 3.1 Receiver Type : LEICA RS500 Satellite System : GPS Serial Number : 80278 Firmware Version : 4.20/1.39 Elevation Cutoff Setting : 5 deg Date Installed : 2006-07-21T00:00Z Date Removed : 2007-10-12T14:00Z Temperature Stabiliz. : 22.5 +/- 2.5 Additional Information : 3.2 Receiver Type : LEICA SR520 Satellite System : GPS Serial Number : 20329 Firmware Version : 5.00/1.33 Elevation Cutoff Setting : 5 deg Date Installed : 2007-10-12T14:00Z Date Removed : 2008-04-02T13:00Z Temperature Stabiliz. : 22.5 +/- 2.5 Additional Information : 3.3 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355290 Firmware Version : 5.62/3.014 Elevation Cutoff Setting : 5 deg Date Installed : 2008-04-04T12:00Z Date Removed : 2008-08-18T11:30Z Temperature Stabiliz. : 22.5 +/- 2.5 Additional Information : 3.4 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355290 Firmware Version : 6.00/3.015 Elevation Cutoff Setting : 5 deg Date Installed : 2008-08-18T11:30Z Date Removed : 2009-04-02T10:35Z Temperature Stabiliz. : 22.5 +/- 2.5 Additional Information : 3.5 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355290 Firmware Version : 7.02/3.016 Elevation Cutoff Setting : 5 deg Date Installed : 2009-04-02T10:35Z Date Removed : 2009-04-22T15:45Z Temperature Stabiliz. : 22.5 +/- 2.5 Additional Information : 3.6 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355290 Firmware Version : 7.02/3.017 Elevation Cutoff Setting : 5 deg Date Installed : 2009-04-22T15:45Z Date Removed : 2010-10-06T08:15Z Temperature Stabiliz. : 22.5 +/- 2.5 Additional Information : 3.7 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355290 Firmware Version : 7.02/3.019 Elevation Cutoff Setting : 5 deg Date Installed : 2010-10-06T17:30Z Date Removed : 2013-01-24T11:42Z Temperature Stabiliz. : 22.5 +/- 2.5 Additional Information : 3.8 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355290 Firmware Version : 8.51/3.019 Elevation Cutoff Setting : 5 deg Date Installed : 2013-01-24T11:58Z Date Removed : 2014-06-18T14:30Z Temperature Stabiliz. : Additional Information : 3.9 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355290 Firmware Version : 8.51/3.054 Elevation Cutoff Setting : 5 deg Date Installed : 2014-06-18T14:47Z Date Removed : 2016-12-29T12:32Z Temperature Stabiliz. : Additional Information : 3.10 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355290 Firmware Version : 8.51/3.055 Elevation Cutoff Setting : 5 deg Date Installed : 2016-12-29T12:46Z Date Removed : 2017-04-20T11:31Z Temperature Stabiliz. : Additional Information : 3.11 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO+SBAS Serial Number : 355290 Firmware Version : 9.20/3.823 Elevation Cutoff Setting : 5 deg Date Installed : 2017-04-20T11:52Z Date Removed : 2019-12-12T16:50Z Temperature Stabiliz. : Additional Information : 3.12 Receiver Type : LEICA GRX1200GGPRO Satellite System : GPS+GLO Serial Number : 355290 Firmware Version : 9.20/3.823 Elevation Cutoff Setting : 0 deg Date Installed : 2019-12-12T16:50Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : Additional Information : 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TRM29659.00 NONE Serial Number : 0220223328 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Antenna Cable Length : Date Installed : 2006-07-21T00:00Z Date Removed : 2008-04-02T13:00Z Additional Information : 4.2 Antenna Type : LEIAT504GG NONE Serial Number : 200455 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 deg Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Antenna Cable Length : 30 m Date Installed : 2008-04-04T12:00Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : Effective Dates : 2006-07-21/CCYY-MM-DD Notes : 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : Met3 Manufacturer : Paroscientific Serial Number : DQ80812 Data Sampling Interval : 900 sec Accuracy (% rel h) : 2 Aspiration : Height Diff to Ant : -0.2 m Calibration date : (CCYY-MM-DD) Effective Dates : 2006-07-21/CCYY-MM-DD Notes : 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : Met3 Manufacturer : Paroscientific Serial Number : DQ80812 Data Sampling Interval : 900 sec Accuracy : 1 hPa Height Diff to Ant : -0.2 m Calibration date : (CCYY-MM-DD) Effective Dates : 2006-07-21/CCYY-MM-DD Notes : 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : Met3 Manufacturer : Paroscientific Serial Number : DQ80812 Data Sampling Interval : 900 sec Accuracy : 0.5 deg C Aspiration : Height Diff to Ant : -0.2 m Calibration date : Effective Dates : 2006-07-21/CCYY-MM-DD Notes : 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.1 Date : 2020-05-23/CCYY-MM-DD Event : antenna stretchers broken 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Direcao-Geral do Territorio Preferred Abbreviation : DGT Mailing Address : Rua Artilharia Um 107 : 1099-052 Lisboa : Portugal Primary Contact Contact Name : Helena Ribeiro Telephone (primary) : +351 21 381 9600 ext. 251 Telephone (secondary) : Fax : +351 21 381 9699 E-mail : hribeiro@dgterritorio.pt Secondary Contact Contact Name : Ana Carla Bernardes Telephone (primary) : +351 21 381 9600 ext. 220 Telephone (secondary) : Fax : +351 21 381 9699 E-mail : abernardes@dgterritorio.pt Additional Information : 12. Responsible Agency (if different from 11.) Agency : Preferred Abbreviation : Mailing Address : Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : 13. More Information Primary Data Center : BKG Secondary Data Center : URL for More Information : http://www.dgterritorio.pt Hardcopy on File Site Map : Site Diagram : Horizon Mask : Monument Description : Site Pictures : Y Additional Information : Antenna Graphics with Dimensions LEIAT504GG L1/L2 Dorne Margolin antenna with chokerings (designed after DORNE MARGOLIN T) +-------+ <-- 0.1393 / + <-- 0.1159 L2 | + | <-- 0.0854 L1 +-----------------+-------------+------------------+ <-- 0.1012 TCR | | | | | | | | +-+--------------------------------------------------+-+ +-------------------+-------------+--------------------+ <-- 0.0345 BCR | | | | +------x------+ <-- 0.0 BPA=ARP <-- 0.3794 --> ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center TCR: Top of Chokering BCR: Bottom of Chokering BPA: Bottom of Preamplifier