International GPS Service CORD Site Information Form See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Dave Stowers Date Prepared : 2003-05-08 Report Type : UPDATE If Update: Previous Site Log : cord_20030425.log Modified/Added Sections : 0, 2, 3.1-3.3, 4.1 1. Site Identification of the GNSS Monument Site Name : Cordoba Four Character ID : CORD Monument Inscription : NONE IERS DOMES Number : 41511M001 CDP Number : (A4) Monument Description : stainless steel pin w/ tread and dimple as mark Height of the Monument : 0.05 Monument Foundation : cemented in concrete roof structure Foundation Depth : 0.20 Marker Description : (CHISELLED CROSS/DIVOT/BRASS NAIL/etc) Date Installed : 1999-07-27 Geologic Characteristic : (BEDROCK/CLAY/CONGLOMERATE/GRAVEL/SAND/etc) Bedrock Type : (IGNEOUS/METAMORPHIC/SEDIMENTARY) Bedrock Condition : (FRESH/JOINTED/WEATHERED) Fracture Spacing : (1-10 cm/10-50 cm/50-200 cm/over 200 cm) Fault zones nearby : (YES/NO/Name of the zone) Distance/activity : (multiple lines) Additional Information : (multiple lines) : CONAE building foundation rests on bedrock : as verified by local geologist who also : identified basement crystalline material : at site. The monument consists of a conquest : pin cemented in the top of a corner column of : the building. It is a 1 inch stainless steel : pin with tread and dimple as mark. A leveling : mount is installed on the conquest pin. : Mark is the center point of the pin. 2. Site Location Information City or Town : Cordoba State or Province : Country : Argentina Tectonic Plate : South American Approximate Position (ITRF) X coordinate (m) : 2345500.0694 Y coordinate (m) : -4910843.8133 Z coordinate (m) : -3316369.0726 Latitude (N is +) : -314236.72 Longitude (E is +) : -0642812.00 Elevation (m,ellips.) : 747.0654, WGS84 Additional Information : (multiple lines) 3. GNSS Receiver Information 3.1 Receiver Type : ROGUE SNR-8000 Satellite System : GPS Serial Number : 375 Firmware Version : 3.2.32.8 Elevation Cutoff Setting : 4 Date Installed : 1999-07-27 Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : none Additional Information : UNAVCO #70014 3.2 Receiver Type : ROGUE SNR-8000 Satellite System : GPS Serial Number : 375 Firmware Version : 3.2.32.8 1s soc2rnx Elevation Cutoff Setting : 4 Date Installed : 2000-08-16 Date Removed : 2003-04-21T14:00Z Temperature Stabiliz. : none Additional Information : UNAVCO #70014 : samplerate - 1s : offload format - soc : conversion to 30s - soc2rnx 3.3 Receiver Type : ROGUE SNR-8000 Satellite System : GPS Serial Number : 375 Firmware Version : 3.2.32.11 Elevation Cutoff Setting : 4 Date Installed : 2003-04-21T20:00Z Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : none Additional Information : Firmware version update : offload format - trb 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS/GLONASS/GPS+GLONASS) Serial Number : (A5) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : AOAD/M_T NONE Serial Number : 118 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0792 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : 1999-07-27 Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : Height measured true vertical to : antenna reference plane for an AOAD/M_T : chokering antenna (7.92 cm) : UNAVCO #8038. 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : dy (m) : dz (m) : Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : CCYY-MM-DD/CCYY-MM-DD Notes : (multiple lines) 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : Accuracy : (mbar) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : CCYY-MM-DD/CCYY-MM-DD Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : CCYY-MM-DD/CCYY-MM-DD Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.1 Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : CCYY-MM-DD/CCYY-MM-DD Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.1 Other Instrumentation : (multiple lines) 8.5.x Other Instrumentation : 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degredations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Comision Nacional de Actividades : Espaciales Preferred Abbreviation : CONAE Mailing Address : Ruta Prov. C45 KM 8 : 5187 Falda de Karmen : PCIA.de Cordoba, Argentina Primary Contact Contact Name : Dr. Carlos Scavuzzo Telephone (primary) : (54)-3547-42-4566 Telephone (secondary) : Fax : (54)-3547-42-4578 E-mail : scavuzzo@tm.conae.gov.ar Secondary Contact Contact Name : Dr. Roberto Sistero Telephone (primary) : (54)-3547-42-0044 Telephone (secondary) : Fax : (54)-3547-42-2713 E-mail : sistero@conae.gov.ar Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : Jet Propulsion Laboratory Preferred Abbreviation : JPL Mailing Address : 4800 Oak Grove Drive : Pasadena, CA : USA 91109 Primary Contact Contact Name : David A. Stowers Telephone (primary) : 818-354-7055 Telephone (secondary) : Fax : 818-393-4965 E-mail : dstowers@jpl.nasa.gov Secondary Contact Contact Name : Network Engineer/UNAVCO Telephone (primary) : 303-497-8000 Telephone (secondary) : Fax : 303-497-8028 E-mail : ruud@unavco.ucar.edu, kfeaux@unavco.ucar.edu Additional Information : Oivind Ruud(x8030) or Karl Feaux(x8037) 13. More Information Primary Data Center : JPL (ODC-Operational Data Center) Secondary Data Center : CDDIS (GDC-Global Data Center) URL for More Information : Hardcopy on File Site Map : (Y or URL) Site Diagram : Y Horizon Mask : Y Monument Description : Y Site Pictures : Y Additional Information : (multiple lines) Antenna Graphics with Dimensions AOAD/M_T ----- / + \ <-- 0.128 L2 | + | <-- 0.110 L1 +--------------------------------------------------+ <-- 0.102 TCR | | | | | | | | +-+--------------------------------------------------+-+ <-- 0.038 +-------------------+-------------+--------------------+ <-- 0.035 BCR | | =| | +------x------+ <-- 0.000 ARP=BPA <-- 0.381 --> ARP: Antenna Reference Point BPA: Bottom of Preamplifier L1 : L1 Phase Center L2 : L2 Phase Center TCR: Top of Chokering BCR: Bottom of Chokering