CONZ Site Information Form (site log) International GPS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Rudi Stoeger Date Prepared : 2005-05-31 Report Type : UPDATE If Update: Previous Site Log : conz_20041015.log Modified/Added Sections : 4.1, 4.2, 12, 13 1. Site Identification of the GNSS Monument Site Name : Concepcion - TIGO Four Character ID : CONZ Monument Inscription : IERS DOMES Number : 41719M002 CDP Number : Monument Description : CONCRETE PILLAR STAINLESS STEAL CONSTRUCTION Height of the Monument : 2.0 Monument Foundation : CONCRETE BLOCK Foundation Depth : 3.0 Marker Description : 5/8" THREAD Date Installed : 2002-05-16T12:00Z Geologic Characteristic : CLAY Bedrock Type : Bedrock Condition : Fracture Spacing : Fault zones nearby : Distance/activity : Additional Information : The site is located in about 20km distance : to the pacific ocean and about 150km from : the nearest vulcanoes of the Andes. 2. Site Location Information City or Town : Concepcion State or Province : VIII Region Country : Chile Tectonic Plate : South-American Approximate Position (ITRF) X coordinate (m) : 1492007.790 Y coordinate (m) : -4887911.140 Z coordinate (m) : -3803640.120 Latitude (N is +) : -365037.54 Longitude (E is +) : -0730131.73 Elevation (m,ellips.) : 00181.2 Additional Information : The site is at the TIGO observatory at the : campus of the Universidad de Concepcion. 3. GNSS Receiver Information 3.1 Receiver Type : JPS LEGACY Satellite System : GPS+GLONASS Serial Number : MT302041021 Firmware Version : RE014 2.2 Elevation Cutoff Setting : 0 Date Installed : 2002-05-16T12:00Z Date Removed : 2002-11-12T12:30Z Temperature Stabiliz. : 5 Additional Information : Additional number LE2130 on the : type level. : The receiver is located in the air : conditioned gravity meter house. 3.2 Receiver Type : JPS LEGACY Satellite System : GPS+GLONASS Serial Number : MT302041021 Firmware Version : 2.2 Jun,13,2002 p3 Elevation Cutoff Setting : 0 Date Installed : 2002-11-12T12:30Z Date Removed : 2003-10-17T08:30Z Temperature Stabiliz. : 5 Additional Information : Additional number LE2130 on the : type level. : The receiver is located in the air : conditioned gravity meter house. 3.3 Receiver Type : JPS LEGACY Satellite System : GPS+GLONASS Serial Number : MT302041021 Firmware Version : 2.3p2 Elevation Cutoff Setting : 0 Date Installed : 2003-10-17T08:30Z Date Removed : 2004-08-24T17:52Z Temperature Stabiliz. : 5 Additional Information : /par/lock/notvis switched to "on". : Additional number LE2130 on the : type level. : The receiver is located in the air : conditioned gravity meter house. 3.4 Receiver Type : JPS LEGACY Satellite System : GPS+GLONASS Serial Number : AGBVRU1GGE8 Firmware Version : 2.3 Apr28,2004 p4 Elevation Cutoff Setting : 0 Date Installed : 2004-10-14T20:41Z Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : 5 Additional Information : /par/lock/notvis switched to "on". : Additional number LE4851 on the : type level. : The receiver is located in the air : conditioned gravity meter house. 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS/GLONASS/GPS+GLONASS) Serial Number : (A5) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : JPSREGANT_DD_E NONE Serial Number : RA0178 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : -00.0125 Marker->ARP North Ecc(m) : 000.0000 Marker->ARP East Ecc(m) : 000.0000 Alignment from True N : 330 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : Nokia Cable M17/75-RG214 Antenna Cable Length : 60 Date Installed : 2002-05-16T12:00Z Date Removed : 2005-05-17T14:30Z Additional Information : The threaded reference pin is penetrating : the antenna by 12.5mm. 4.2 Antenna Type : TPSCR3_GGD CONE Serial Number : 217 0246 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 000.0556 Marker->ARP North Ecc(m) : 000.0000 Marker->ARP East Ecc(m) : 000.0000 Alignment from True N : 0 Antenna Radome Type : CONE Radome Serial Number : Antenna Cable Type : Nokia Cable M17/75-RG214 Antenna Cable Length : 60 Date Installed : 2005-05-17T14:30Z Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.1 Tied Marker Name : T100 Tied Marker Usage : VLBI Tied Marker CDP Number : 7640 Tied Marker DOMES Number : 41719S001 Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5.2 Tied Marker Name : T200 Tied Marker Usage : SLR Tied Marker CDP Number : 7405 Tied Marker DOMES Number : 41719M001 Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : Effective Dates : 2002-05-16/CCYY-MM-DD Notes : 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : VLBI Status : PERMANENT Effective Dates : 2002-04-23/CCYY-MM-DD Notes : 7.2 Instrumentation Type : SLR Status : MOBILE Effective Dates : 2002-05-01/CCYY-MM-DD Notes : 7.3 Instrumentation Type : PRARE Status : PERMANENT Effective Dates : 2002-06-15/CCYY-MM-DD Notes : 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : 809 Manufacturer : Lambrecht Serial Number : Data Sampling Interval : 60 Accuracy (% rel h) : 2.5 Aspiration : PERNIX Height Diff to Ant : 10 Calibration date : (CCYY-MM-DD) Effective Dates : 2002-04-01/CCYY-MM-DD Notes : The humidity sensor is about 10 m below : GPS monument in 50 m distance. 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : 740-16B DIGIQUARTZ Manufacturer : PAROSCIENTIFIC Serial Number : Data Sampling Interval : 60 Accuracy : 0.1 Height Diff to Ant : 15 Calibration date : (CCYY-MM-DD) Effective Dates : 2002-04-01/CCYY-MM-DD Notes : The pressure sensor is located inside : TIGO-3 and about 15 m below GPS antenna. 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : 809 Manufacturer : Lambrecht Serial Number : Data Sampling Interval : 60 Accuracy : 0.3 Aspiration : PLATINUM PROBE Height Diff to Ant : 10 Calibration date : (CCYY-MM-DD) Effective Dates : 2002-04-01/CCYY-MM-DD Notes : The temperature sensor is about 10 m below : the GPS-antenna in about 50 m distance. 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.1 Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.1 Other Instrumentation : Tiltmeter inside the GPS-monument 8.5.2 Other Instrumentation : Broadband Seismometer 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Universidad de Concepcion Preferred Abbreviation : UdeC Mailing Address : Universidad de Concepcion : Proyecto TIGO : Casilla 4036, Correo 3 : Concepcion : CHILE Primary Contact Contact Name : Armin Boer Telephone (primary) : +56-41-207034 Telephone (secondary) : +56-41-207053 Fax : +56-41-207031 E-mail : gps@tigo.cl, armin.boer@tigo.cl Secondary Contact Contact Name : Hayo Hase Telephone (primary) : +56-41-207032 Telephone (secondary) : +56-41-207051 Fax : +56-41-207031 E-mail : hayo.hase@tigo.cl Additional Information : 12. Responsible Agency (if different from 11.) Agency : Bundesamt für Kartographie und Geodäsie Preferred Abbreviation : BKG Mailing Address : Fundamentalstation Wettzell : Sackenrieder Str. 25 : D-93444 Kötzting : GERMANY Primary Contact Contact Name : Wolfgang Schlueter Telephone (primary) : ++49-9941-603107 Telephone (secondary) : ++49-9941-603106 Fax : ++49-9941-603222 E-mail : schlueter@wettzell.ifag.de Secondary Contact Contact Name : Uwe Hessels Telephone (primary) : ++49-9941-603204 Telephone (secondary) : ++49-9941-6030 Fax : ++49-9941-603222 E-mail : uwe.hessels@bkg.bund.de Additional Information : Klaus Roettcher : ++49-9941-603115 : roettcher@wettzell.ifag.de : Rudi Stoeger : ++49-9941603117 : ++49-99416030 : ++49-9941603222 : stoeger@wettzell.ifag.de 13. More Information Primary Data Center : BKGI Secondary Data Center : IGN URL for More Information : www.tigo.cl, www.wettzell.ifag.de Hardcopy on File Site Map : (Y or URL) Site Diagram : (Y or URL) Horizon Mask : (Y or URL) Monument Description : (Y or URL) Site Pictures : Y Additional Information : (multiple lines) Antenna Graphics with Dimensions JPSREGANT_DD_E From 2002-05-16 until 2005-05-17 +-------------------------+ <--------------Plastic Housing for / ------------------- \ Antenna/Choke Ring / / + \ \ <-- 0.1186 L2 +---------+ | + | +---------+ <-- 0.1131 L1 | +-------------------------------------------------+ | <-- 0.xxxx TCR / | | \ | | | | | | | | | | | | \+-----------------------------------------------------+/ |+-----------------------------------------------------+| <-- 0.xxxx BCR \______________ | | ______________/ \ | | / \+---------x---------+/ <-- 0.0000 BPA=ARP TPSCR3_GGD After 2005-05-17 --------- / + \ <-- 0.104 L2 | + | <-- 0.081 L1 +--------------------------------------------------+ <-- 0.071 TCR | | | | | | | | +-----------------+-------------+------------------+ <-- 0.003 BCR +-----x-----+ <-- 0.000 BPA=ARP <-- 0.326 --> ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center TCR: Top of Chokering BCR: Bottom of Chokering TGP: Top of Ground Plane BGP: Bottom of Ground Plane TPA: Top of Preamplifier BPA: Bottom of Preamplifier TOP: Top of Pole