International GPS Service BAKO Site Information Form See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Cecep SUBARYA Date Prepared : 2000-11-11 Report Type : UPDATE If Update: Previous Site Log : bako0101.log Modified/Added Sections : (n.n,n.n,...) 1. Site Identification of the GNSS Monument Site Name : BAKOSURTANAL Four Character ID : BAKO Monument Inscription : Concrete Pilar, 50 cm above ground level IERS DOMES Number : 23101M002 CDP Number : (A4) Monument Description : (PILLAR/BRASS PLATE/STEEL MAST/etc) Height of the Monument : (m) Monument Foundation : (STEEL RODS, CONCRETE BLOCK, ROOF, etc) Foundation Depth : (m) Marker Description : (CHISELLED CROSS/DIVOT/BRASS NAIL/etc) Date Installed : 1981-06-12T00:00Z Geologic Characteristic : Alluvial Bedrock Type : SEDIMENTARY Bedrock Condition : (FRESH/JOINTED/WEATHERED) Fracture Spacing : (1-10 cm/10-50 cm/50-200 cm/over 200 cm) Fault zones nearby : (YES/NO/Name of the zone) Distance/activity : (multiple lines) Additional Information : (multiple lines) : size : Permanent tripod (stainless-still) above the : pillar 2. Site Location Information City or Town : Cibinong State or Province : West Java Country : Indonesia Tectonic Plate : Eurasia Approximate Position (ITRF) X coordinate (m) : -1836968.9684 Y coordinate (m) : +6065617.1296 Z coordinate (m) : -716257.7685 Latitude (N is +) : -062927.96 Longitude (E is +) : +1065056.04 Elevation (m,ellips.) : +158.1365 m (above ellipsoid WGS84) Additional Information : +138.4550 m ( above mean sea level) 3. GNSS Receiver Information 3.1 Receiver Type : TRIMBLE 4000SSE Satellite System : (GPS/GLONASS/GPS+GLONASS) Serial Number : 3305A02491 Firmware Version : 6.12 / 2.12 Elevation Cutoff Setting : (deg) Date Installed : 1998-02-07T00:00Z Date Removed : 2000-11-11T00:00Z Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 3.2 Receiver Type : TRIMBLE 4000SSI Satellite System : (GPS/GLONASS/GPS+GLONASS) Serial Number : 3547A13477 Firmware Version : NP 7.19 ; SP3.04 Elevation Cutoff Setting : (deg) Date Installed : 2000-11-11T00:00Z Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS/GLONASS/GPS+GLONASS) Serial Number : (A5) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TRM14532.00 Serial Number : 0220044159 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 1.616 m (vertical measurement) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : 0 degrees Antenna Radome Type : Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : 1998-02-07T00:00Z Date Removed : 2000-11-11T00:00Z Additional Information : Antenna height refers to bottom of ground plane : measured from station mark. 4.2 Antenna Type : TRM14532.00 Serial Number : 0220044138 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 1.616 (m) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : Antenna Radome Type : Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : 2000-11-11T00:00Z Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : 4000ST L1/L2 Geodetic, Model 14532.00 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : dy (m) : dz (m) : Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : (H-MASER/CESIUM/QUARTZ/INTERNAL/RUBIDIUM) Input Frequency : Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : DORIS Status : PERMANENT Effective Dates : 1998-05-19/CCYY-MM-DD Notes : Measurement tie by using GPS geodetic : receiver Trimble 4000SSi observation start : 00h:00m finished 23h:59m UT. : (more information contact IGN, Z. Altamimi) 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : CCYY-MM-DD/CCYY-MM-DD Notes : (multiple lines) 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : Accuracy : (mbar) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : CCYY-MM-DD/CCYY-MM-DD Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : CCYY-MM-DD/CCYY-MM-DD Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.1 Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : CCYY-MM-DD/CCYY-MM-DD Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.1 Other Instrumentation : (multiple lines) 8.5.x Other Instrumentation : 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degredations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDLINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : BAKOSURTANAL : Nat. Coordination Agency for Surveys and Mapping Preferred Abbreviation : (A10) Mailing Address : Jl. Raya Jakarta-Bogor Km.46 : Cibinong 16911 : Jawa Barat - Indonesia Primary Contact Contact Name : Cecep SUBARYA Telephone (primary) : 62 21 875 7329 Telephone (secondary) : 62 21 875 2062 ext. 297 Fax : 62 21 875 3289 E-mail : geodesi@indo.net.id Secondary Contact Contact Name : Asadi Telephone (primary) : 62 21 875 7329 Telephone (secondary) : 62 21 875 2062 Fax : 62 21 875 3289 E-mail : geodesi@indo.net.id Additional Information : (multiple lines) 12. Responsible Agency (if different from 11.) Agency : (multiple lines) Preferred Abbreviation : (A10) Mailing Address : (multiple lines) Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information URL for More Information : Hardcopy on File Site Map : (Y or URL) Site Diagram : Yes Horizon Mask : 15 degress Monument Description : Yes Site Pictures : Yes Additional Information : (multiple lines) Antenna Graphics with Dimensions