BAIE Site Information Form (site log) International GPS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Peter Taylor & Stephen Delahunt Date Prepared : 2004-02-26 Report Type : UPDATE If Update: Previous Site Log : baie_20030305.log Modified/Added Sections : 12 1. Site Identification of the GNSS Monument Site Name : BAIE CACS-ACP Four Character ID : BAIE Monument Inscription : M012001 IERS DOMES Number : 40151M001 CDP Number : Monument Description : concrete pillar Height of the Monument : 1.50 Monument Foundation : bedrock Foundation Depth : 3.00 Marker Description : brass plate Date Installed : 2001-11-04 Geologic Characteristic : BEDROCK Bedrock Type : Bedrock Condition : Fracture Spacing : Fault zones nearby : Distance/activity : Additional Information : The GPS reference mark consists of a forced : centering brass plate on top of a 1.5 metre : (above grade) 40cm diameter concrete pillar : anchored to bedrock. 2. Site Location Information City or Town : BAIE COMEAU State or Province : Quebec Country : CANADA Tectonic Plate : North American Approximate Position (ITRF) X coordinate (m) : 1546823.34 Y coordinate (m) : -3879765.13 Z coordinate (m) : 4804185.05 Latitude (N is +) : +491112.57 Longitude (E is +) : -0681547.98 Elevation (m,ellips.) : 27.48 Additional Information : GPS equipment located in the computer room of : the CEGEP Campus, in Baie Comeau, Quebec. 3. GNSS Receiver Information 3.1 Receiver Type : AOA BENCHMARK ACT Satellite System : GPS Serial Number : 1116 Firmware Version : 3.3.32.2N Elevation Cutoff Setting : 10 Date Installed : 2001-11-04T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : NONE Additional Information : 4. GNSS Antenna Information 4.1 Antenna Type : AOAD/M_T Serial Number : 467 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.1000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : 0.0000 Antenna Radome Type : NONE Radome Serial Number : Antenna Cable Type : LDF4-50A Antenna Cable Length : Date Installed : 2001-11-04T00:00Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : INTERNAL Input Frequency : 5 MHZ Effective Dates : 2001-11-04 Notes : 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : HMP-35A Manufacturer : VAISALA Serial Number : XXX Data Sampling Interval : 900.00 SEC. Accuracy (% rel h) : 5.00 Aspiration : NONE Height Diff to Ant : 0.00 m. Calibration date : Effective Dates : 2001-11-04 Notes : 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : PTB-100A Manufacturer : VAISALA Serial Number : XXX Data Sampling Interval : 900.00 SEC. Accuracy : 0.25 Mbar. Aspiration : NONE Height Diff to Ant : 0.00 m. Calibration date : Effective Dates : 2001-11-04 Notes : The readings are modeled as a function of the : pressure transducer output and the : temperature. 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : VSI 44212 Manufacturer : VSI Serial Number : XXX Data Sampling Interval : 900.00 SEC. Accuracy : 0.20 deg. C. Aspiration : NONE Height Diff to Ant : 0.00 m. Calibration date : Effective Dates : 2001-11-04 Notes : 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.1 Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.1 Other Instrumentation : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position: NONE 10. Local Episodic Effects Possibly Affecting Data Quality: NONE 11. On-Site, Point of Contact Agency Information Agency : NRCan/GEODETIC SURVEY OF CANADA Preferred Abbreviation : NRCan/GSD Mailing Address : 615 Booth St., Ottawa, Ontario : CANADA, K1A 0E9 Primary Contact Contact Name : Mark Caissy Telephone (primary) : 613-995-4024 Telephone (secondary) : Fax : 613-995-3215 E-mail : mark.caissy@nrcan.gc.ca Secondary Contact Contact Name : Peter Taylor Telephone (primary) : 613-992-2106 Telephone (secondary) : Fax : 613-995-3215 E-mail : peter.taylor@nrcan.gc.ca Additional Information : 12. Responsible Agency (if different from 11.) Agency : Joint NRCan-Ottawa/GeoForchungsZentrum-Potsdam Preferred Abbreviation : NRCan/GFZ Mailing Address : 615 Booth St., Ottawa, Ontario : CANADA, K1A 0E9 Primary Contact Contact Name : Mark Caissy Telephone (primary) : 613-995-4024 Telephone (secondary) : Fax : 613-995-3215 E-mail : mark.caissy@nrcan.gc.ca Secondary Contact Contact Name : Dr. Roman Galas Telephone (primary) : (+49) -331-2881179 Telephone (secondary) : (+49) -331-4729142 Fax : (+49) -331-2881111 E-mail : galas@gfz-potsdam.de Additional Information : Natural Resources Canada (NRCan) and : GeoForschungsZentrum (GFZ) are jointly : responsible for this site. It is being used for : postglacial rebound investigation. 13. More Information Primary Data Center : CDDIS Secondary Data Center : NRCan URL for More Information : Hardcopy on File Site Map : Site Diagram : Horizon Mask : Monument Description : Site Pictures : Additional Information : Antenna Graphics with Dimensions Type: AOAD/M_T --- L2 Phase Center => / + \ <---------------+ L1 Phase Center => | + | <---------+ | +----------------------------------------------+ | | | | | | | | | | | | | | | | | | ================================================== | | | | | | | +-+ | | 0.228m Bottom of Preamp. (BPA) => +====| |====+ <--+ | | | | | 0.210m | | | | | | | | | | | Mount => | | 0.100m | | | | | | | | | | | | | +-+ | | | | Monument => +----------------+====| |====+-----------------+ <--+-----+ Ref. Point | | | | | | | Concrete Pillar | | | | | | | BPA: Bottom of Preamplifier L1 : L1 Phase Center L2 : L2 Phase Center TCR: Top of Chokering BCR: Bottom of Chokering BPA: Bottom of Preamplifier L1 : L1 Phase Center L2 : L2 Phase Center TCR: Top of Chokering BCR: Bottom of Chokering