IITK00IND Site Information Form (site log) International GNSS Service See Instructions at: https://files.igs.org/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : mohammadchoudhury Date Prepared : 2023-03-15 Report Type : UPDATE If Update: Previous Site Log : (ssss_ccyymmdd.log) Modified/Added Sections : (n.n,n.n,...) 1. Site Identification of the GNSS Monument Site Name : Indian Institute of Technology Kanpur Four Character ID : IITK Monument Inscription : Square and a dot IERS DOMES Number : 22317M001 CDP Number : Monument Description : Concrete Pillar Height of the Monument : 4.75 m Monument Foundation : Concrete Foundation Depth : 1.5 m Marker Description : Stainless steel plate Date Installed : 2021-03-31T00:00Z Geologic Characteristic : Hard Clay Bedrock Type : Bedrock Condition : Fracture Spacing : Fault zones nearby : Faizabad fault Distance/activity : 231 km approximately Additional Information : The station runs on Institute’s uninterrupted : power supply. Marker is a stainless steel plate : that is inserted 0.3 m into the concrete pillar. 2. Site Location Information City or Town : Kanpur State or Province : Uttar Pradesh Country : India Tectonic Plate : INDIAN Approximate Position (ITRF) X coordinate (m) : 968880.6487 Y coordinate (m) : 5628037.6499 Z coordinate (m) : 2830900.7294 Latitude (N is +) : +263117.12 Longitude (E is +) : +0801355.68 Elevation (m,ellips.) : 71.7 Additional Information : 3. GNSS Receiver Information 3.1 Receiver Type : TRIMBLE ALLOY Satellite System : GPS+GLO+GAL+BDS+QZSS+IRNSS Serial Number : 6006R44002 Firmware Version : 5.44 Elevation Cutoff Setting : 0 deg Date Installed : 2021-03-31T11:54Z Date Removed : 2021-12-23T23:59Z Temperature Stabiliz. : none Additional Information : 3.2 Receiver Type : TRIMBLE ALLOY Satellite System : GPS+GLO+GAL+BDS+QZSS+IRNSS Serial Number : 6006R44002 Firmware Version : 5.45 Elevation Cutoff Setting : 0 deg Date Installed : 2021-12-24T00:00Z Date Removed : 2023-01-10T05:51Z Temperature Stabiliz. : none Additional Information : 3.3 Receiver Type : TRIMBLE ALLOY Satellite System : GPS+GLO+GAL+BDS+QZSS+IRNSS Serial Number : 6006R44002 Firmware Version : 6.16 Elevation Cutoff Setting : 0 deg Date Installed : 2023-01-10T05:51Z Date Removed : CCYY-MM-DDThh:mmZ Temperature Stabiliz. : none Additional Information : 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : TRM159900.00 SCIS Serial Number : 5842338432 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 000.3080 Marker->ARP North Ecc(m) : 000.0000 Marker->ARP East Ecc(m) : 000.0000 Alignment from True N : 0 deg Antenna Radome Type : SCIS Radome Serial Number : Antenna Cable Type : Times Microwave Systems and LMR-400 Coaxial Cabl Antenna Cable Length : 30.0 m Date Installed : 2021-03-31T23:56Z Date Removed : CCYY-MM-DDThh:mmZ Additional Information : 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : PTU 307 Manufacturer : VAISALA Serial Number : S0730797 Data Sampling Interval : 15 sec Accuracy (% rel h) : 1.00 Aspiration : Height Diff to Ant : 5.86 m Calibration date : (CCYY-MM-DD) Effective Dates : 2021-07-03/CCYY-MM-DD Notes : All the three sensors i.e Humidity, Pressure and : Temperature are integreated within VAISALA : PTU307 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : PTU 307 Manufacturer : VAISALA Serial Number : S0730797 Data Sampling Interval : 15 sec Accuracy : 0.07 hPa Height Diff to Ant : 5.86 m Calibration date : (CCYY-MM-DD) Effective Dates : 2021-07-03/CCYY-MM-DD Notes : 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : PTU 307 Manufacturer : VAISALA Serial Number : S0730797 Data Sampling Interval : 15 sec Accuracy : 0.10 deg C Aspiration : Height Diff to Ant : 5.86 m Calibration date : Effective Dates : 2021-07-03/CCYY-MM-DD Notes : 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Indian Institute of Technology Kanpur Preferred Abbreviation : Mailing Address : National Centre for Geodesy, : Indian Institute of Technology Kanpur : Kanpur : 208016 : India Primary Contact Contact Name : National Centre for Geodesy Telephone (primary) : 05122597937 Telephone (secondary) : 05122597722 Fax : E-mail : ncg@iitk.ac.in Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : 12. Responsible Agency (if different from 11.) Agency : Indian Institute of Technology Kanpur Preferred Abbreviation : Mailing Address : National Centre for Geodesy, : Indian Institute of Technology Kanpur : Kanpur : 208016 : India Primary Contact Contact Name : National Centre for Geodesy Telephone (primary) : 05122597937 Telephone (secondary) : 05122597722 Fax : E-mail : ncg@iitk.ac.in Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : 13. More Information Primary Data Center : Secondary Data Center : URL for More Information : Hardcopy on File Site Map : Site Diagram : Horizon Mask : Monument Description : Site Pictures : Additional Information : Antenna Graphics with Dimensions (insert text graphic from file antenna.gra)