KGN000JPN Site Information Form (site log) International GNSS Service See Instructions at: https://files.igs.org/pub/station/general/sitelog_instr_v2.0.txt 0. Form Prepared by (full name) : Tadahiro GOTOH Date Prepared : 2006-02-07 Report Type : UPDATE If Update: Previous Site Log : kgn0_20030623.log Modified/Added Sections : 6.1, 6.2 1. Site Identification of the GNSS Monument Site Name : Koganei Time Transfer Station Nine Character ID : KGN000JPN Monument Inscription : no monument, GPS antenna reference point IERS DOMES Number : 21704S006 CDP Number : none Monument Description : Steel Pillar Height of the Monument : 2.3 m Monument Foundation : Roof Foundation Depth : Marker Description : Date Installed : 1999-10-01T00:00Z Geologic Characteristic : Pillar Bedrock Type : Bedrock Condition : Fracture Spacing : Fault zones nearby : Distance/activity : Additional Information : (multiple lines) : Antenna is placed on a Pillar ( Scaffold ) : on the top of the 4 stories building. 2. Site Location Information City or Town : Koganei State or Province : Tokyo Country or Region : JPN Tectonic Plate : NORTH AMERICAN Approximate Position (ITRF) X coordinate (m) : -3942148.9090 Y coordinate (m) : 3368281.8900 Z coordinate (m) : 3701898.6110 Latitude (N is +) : +354224.48 Longitude (E is +) : +1392918.60 Elevation (m) : 128.5 Additional Information : WGS-84 3. GNSS Receiver Information 3.1 Receiver Type : ASHTECH Z-XII3 Satellite System : GPS Serial Number : RT90103 DEVIATION#241 Firmware Version : NAV:1L01(08/03/99 10:23) Elevation Cutoff Setting : Date Installed : 1999-10-01T00:00Z Date Removed : 2002-06-11T00:00Z Temperature Stabiliz. : Additional Information : Navigation Boad Type is MCF, 10.4 Megabytes, : Channel Firmware Version is 1D04 (07/29/97 3.2 Receiver Type : ASHTECH Z-XII3T Satellite System : GPS Serial Number : RT90103 DEVIATION#241 Firmware Version : NAV:1L01(08/03/99 10:23) Elevation Cutoff Setting : Date Installed : 2002-06-11T00:00Z Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : Additional Information : 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : ASH701933A_M SCIS Serial Number : CRN21999080101 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0.0000 Marker->ARP North Ecc(m) : 0.0000 Marker->ARP East Ecc(m) : 0.0000 Alignment from True N : Antenna Radome Type : SCIS Radome Serial Number : Antenna Cable Type : Antenna Cable Length : Date Installed : 1999-10-01T00:00Z Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : SCIGN radome 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : EXTERNAL STEERED CESIUM Input Frequency : 5.0 MHz Effective Dates : 2001-07-01/2006-02-07 Notes : Frequency source is UTC(CRL). We use a 4 : multiplier made by KVARZ (Model:MU-0520-10) : and input this 20MHz signal to the receiver. 6.2 Standard Type : EXTERNAL CESIUM Input Frequency : 5.0 MHz Effective Dates : 2006-02-07/CCYY-MM-DD Notes : We use a 4 multiplier made by KVARZ : (Model:MU-0520-10) and input this 20MHz signal : to the receiver. 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : National Institute of : Information and Communications Technology Preferred Abbreviation : NICT Mailing Address : 4-2-1, Nukuikita-machi, Koganei, Tokyo : 184-8795 Japan Primary Contact Contact Name : Tadahiro GOTOH Telephone (primary) : 81-42-327-6850 Telephone (secondary) : Fax : 81-42-327-6664 E-mail : tara@nict.go.jp Secondary Contact Contact Name : Jun AMAGAI Telephone (primary) : 81-42-327-7494 Telephone (secondary) : Fax : 81-42-327-5812 E-mail : amagai@nict.go.jp Additional Information : Supervisor Shin'ichi Hama : Tel 81-42-327-5690 : Fax 81-42-327-5812 : E-mail hamashin@nict.go.jp 12. Responsible Agency (if different from 11.) Agency : (multiple lines) Preferred Abbreviation : (A10) Mailing Address : (multiple lines) Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : (multiple lines) 13. More Information Primary Data Center : Secondary Data Center : URL for More Information : Hardcopy on File Site Map : (Y or URL) Site Diagram : (Y or URL) Horizon Mask : (Y or URL) Monument Description : (Y or URL) Site Pictures : (Y or URL) Additional Information : (multiple lines) Antenna Graphics with Dimensions Ashtech: DORNE MARGOLIN ASH ASH701933C_M +---------+ / + \ <-- 0.1280 L2 | + | <-- 0.1100 L1 +-----------------+-------------+------------------+ <-- 0.1008 TCR | | | | | | | | +-+--------------------------------------------------+-+ <-- 0.0378 +-------------------+-------------+--------------------+ <-- 0.0348 BCR | | | | +------x------+ <-- 0.0000 BPA=ARP <-- 0.3794 -->