CONT Site Information Form (site log) International GNSS Service See Instructions at: ftp://igscb.jpl.nasa.gov/pub/station/general/sitelog_instr.txt 0. Form Prepared by (full name) : Rudi Stoeger Date Prepared : 2014-09-26 Report Type : UPDATE If Update: Previous Site Log : cont_20100215.log Modified/Added Sections : 1, 3.1, 4.1 1. Site Identification of the GNSS Monument Site Name : Concepcion - TIGO Four Character ID : CONT Monument Inscription : IERS DOMES Number : 41719M004 CDP Number : Monument Description : CONCRETE PILLAR Height of the Monument : 4.2 m Monument Foundation : CONCRETE BLOCK Foundation Depth : 3.0 m Marker Description : 5/8" THREAD Date Installed : 2005-08-16T13:00Z Geologic Characteristic : CLAY Bedrock Type : Bedrock Condition : Fracture Spacing : Fault zones nearby : Distance/activity : Additional Information : This site is located in about : 20km distance to the pacific ocean : and about 150km to the nearest : vulcanoes of the Andes. : Station decomissioned on 2014-09-22. 2. Site Location Information City or Town : Concepcion State or Province : VIII Region Country : Chile Tectonic Plate : SOUTH AMERICAN Approximate Position (ITRF) X coordinate (m) : 1492070.5609 Y coordinate (m) : -4887972.6300 Z coordinate (m) : -3803568.6023 Latitude (N is +) : -365034.18 Longitude (E is +) : -0730130.03 Elevation (m,ellips.) : 00200.027 Additional Information : The site is at the TIGO observatory at the : campus of the Universidad de Concepcion. 3. GNSS Receiver Information 3.1 Receiver Type : SEPT POLARX2 Satellite System : GPS Serial Number : 1377 Firmware Version : 2.6.0 Elevation Cutoff Setting : 0 deg Date Installed : 2005-08-17T00:00Z Date Removed : 2014-09-22T21:00Z Temperature Stabiliz. : none Additional Information : The receiver is installed in a 40ft : container with air condition. : The receiver is feeded by an external : 10 MHz frequency reference from : H-maser : Station decomissioned on 2014-09-22. 3.x Receiver Type : (A20, from rcvr_ant.tab; see instructions) Satellite System : (GPS+GLO+GAL+BDS+QZSS+SBAS) Serial Number : (A20, but note the first A5 is used in SINEX) Firmware Version : (A11) Elevation Cutoff Setting : (deg) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Temperature Stabiliz. : (none or tolerance in degrees C) Additional Information : (multiple lines) 4. GNSS Antenna Information 4.1 Antenna Type : ASH700936E SNOW Serial Number : CR16008 Antenna Reference Point : BPA Marker->ARP Up Ecc. (m) : 0000.0311 Marker->ARP North Ecc(m) : 0000.0000 Marker->ARP East Ecc(m) : 0000.0000 Alignment from True N : 0 deg Antenna Radome Type : SNOW Radome Serial Number : Antenna Cable Type : RG-8 Antenna Cable Length : 20.5 m Date Installed : 2005-08-16T15:30Z Date Removed : 2014-09-22T21:00Z Additional Information : Station decomissioned on 2014-09-22. 4.x Antenna Type : (A20, from rcvr_ant.tab; see instructions) Serial Number : (A*, but note the first A5 is used in SINEX) Antenna Reference Point : (BPA/BCR/XXX from "antenna.gra"; see instr.) Marker->ARP Up Ecc. (m) : (F8.4) Marker->ARP North Ecc(m) : (F8.4) Marker->ARP East Ecc(m) : (F8.4) Alignment from True N : (deg; + is clockwise/east) Antenna Radome Type : (A4 from rcvr_ant.tab; see instructions) Radome Serial Number : Antenna Cable Type : (vendor & type number) Antenna Cable Length : (m) Date Installed : (CCYY-MM-DDThh:mmZ) Date Removed : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 5. Surveyed Local Ties 5.1 Tied Marker Name : T100 Tied Marker Usage : VLBI Tied Marker CDP Number : 7640 Tied Marker DOMES Number : 41719S001 Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : dy (m) : dz (m) : Accuracy (mm) : Survey method : Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : 5.2 Tied Marker Name : T200 Tied Marker Usage : SLR Tied Marker CDP Number : 7405 Tied Marker DOMES Number : 41719M001 Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : dy (m) : dz (m) : Accuracy (mm) : Survey method : Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : 5.3 Tied Marker Name : TPS E_GGD = CONZ Tied Marker Usage : GPS+GLONASS Tied Marker CDP Number : Tied Marker DOMES Number : 41719M002 Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : dy (m) : dz (m) : Accuracy (mm) : Survey method : Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : 5.x Tied Marker Name : Tied Marker Usage : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc) Tied Marker CDP Number : (A4) Tied Marker DOMES Number : (A9) Differential Components from GNSS Marker to the tied monument (ITRS) dx (m) : (m) dy (m) : (m) dz (m) : (m) Accuracy (mm) : (mm) Survey method : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc) Date Measured : (CCYY-MM-DDThh:mmZ) Additional Information : (multiple lines) 6. Frequency Standard 6.1 Standard Type : EXTERNAL H-MASER Input Frequency : 10 MHz Effective Dates : 2005-08-17/CCYY-MM-DD Notes : 6.x Standard Type : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc) Input Frequency : (if external) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 7. Collocation Information 7.1 Instrumentation Type : VLBI Status : PERMANENT Effective Dates : 2002-04-23/CCYY-MM-DD Notes : 7.2 Instrumentation Type : SLR Status : MOBILE Effective Dates : 2002-05-01/CCYY-MM-DD Notes : 7.3 Instrumentation Type : PRARE Status : PERMANENT Effective Dates : 2002-06-15/CCYY-MM-DD Notes : 7.4 Instrumentation Type : JPS LEGACY GPS+GLONASS CONZ Status : PERMANENT Effective Dates : 2002-05-16/2006-06-22 Notes : Four character ID CONZ 7.5 Instrumentation Type : TPS E_GGD GPS+GLONASS CONZ Status : PERMANENT Effective Dates : 2006-06-22/2009-04-30 Notes : Four character ID CONZ 7.6 Instrumentation Type : LEICA GRX1200GGPRO GPS+GLONASS CONZ Status : PERMANENT Effective Dates : 2009-04-30/CCYY-MM-DD Notes : Four character ID CONZ 7.7 Instrumentation Type : Supra Conducting Gravitymeter Status : PERMANENT Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : 7.8 Instrumentation Type : Broadband Seismometer Status : PERMANENT Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : 7.x Instrumentation Type : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc) Status : (PERMANENT/MOBILE) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8. Meteorological Instrumentation 8.1.1 Humidity Sensor Model : 809 Manufacturer : Lamprecht Serial Number : Data Sampling Interval : 60) sec Accuracy (% rel h) : 2.5 Aspiration : PERNIX Height Diff to Ant : - 0.7 m Calibration date : (CCYY-MM-DD) Effective Dates : 2002-04-01/CCYY-MM-DD Notes : The humidity sensor is 0.7 m : above the antenna. : The horizontal distance to : the antenna is 7 m. 8.1.x Humidity Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy (% rel h) : (% rel h) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.2.1 Pressure Sensor Model : 740-16B DIGIQUARTZ Manufacturer : PAROSCIENTIFIC Serial Number : Data Sampling Interval : 60 sec Accuracy : 0.1 hPa Height Diff to Ant : 3.5 m Calibration date : (CCYY-MM-DD) Effective Dates : 2002-04-01/CCYY-MM-DD Notes : The pressure sensor is 3.5 m : below the antenna. : The horizontal distance to : the antenna is 2.5 m. 8.2.x Pressure Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (hPa) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.3.1 Temp. Sensor Model : 809 Manufacturer : Lamprecht Serial Number : Data Sampling Interval : 60 sec Accuracy : 0.3 deg C Aspiration : PLATINUM PROBE Height Diff to Ant : - 0.7 m Calibration date : Effective Dates : 2002-04-01/CCYY-MM-DD Notes : The temperature sensor is : 0.7 m above the antenna. : The horizontal distance to : the antenna is 7 m. 8.3.x Temp. Sensor Model : Manufacturer : Serial Number : Data Sampling Interval : (sec) Accuracy : (deg C) Aspiration : (UNASPIRATED/NATURAL/FAN/etc) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.4.1 Water Vapor Radiometer : Passive Microwave Radiometer Manufacturer : CAPTEC GmbH Zurich Serial Number : CTWT129703 Distance to Antenna : 4 m Height Diff to Ant : 0.3 m Calibration date : Effective Dates : 2003-03-01/CCYY-MM-DD Notes : The Microwave Radiometer is : 0.3 m below the antenna. 8.4.x Water Vapor Radiometer : Manufacturer : Serial Number : Distance to Antenna : (m) Height Diff to Ant : (m) Calibration date : (CCYY-MM-DD) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Notes : (multiple lines) 8.5.x Other Instrumentation : (multiple lines) 9. Local Ongoing Conditions Possibly Affecting Computed Position 9.1.x Radio Interferences : (TV/CELL PHONE ANTENNA/RADAR/etc) Observed Degradations : (SN RATIO/DATA GAPS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.2.x Multipath Sources : (METAL ROOF/DOME/VLBI ANTENNA/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 9.3.x Signal Obstructions : (TREES/BUILDINGS/etc) Effective Dates : (CCYY-MM-DD/CCYY-MM-DD) Additional Information : (multiple lines) 10. Local Episodic Effects Possibly Affecting Data Quality 10.x Date : (CCYY-MM-DD/CCYY-MM-DD) Event : (TREE CLEARING/CONSTRUCTION/etc) 11. On-Site, Point of Contact Agency Information Agency : Universidad de Concepcion Preferred Abbreviation : UdeC Mailing Address : Universidad de Concepcion : Proyecto TIGO : Casilla 4036, Correo 3 : Concepcion : Chile Primary Contact Contact Name : Armin Boer Telephone (primary) : ++56-41-2207034 Telephone (secondary) : ++56-41-2207053 Fax : ++56-41-2207031 E-mail : gps@tigo.cl, armin.boer@tigo.cl Secondary Contact Contact Name : Hayo Hase Telephone (primary) : ++56-41-2207032 Telephone (secondary) : ++56-41-2207051 Fax : ++56-41-2207031 E-mail : hayo.hase@tigo.cl Additional Information : 12. Responsible Agency (if different from 11.) Agency : Bundesamt fuer Kartographie und Geodaesie Preferred Abbreviation : BKG Mailing Address : Bundesamt fuer Kartographie und Geodaesie : Geodetical Observatory Wettzell : Sackenrieder Strasse 25 : D-93444 Bad Koetzting : Germany Primary Contact Contact Name : Reiner Dassing Telephone (primary) : ++49-9941-603112 Telephone (secondary) : ++49-9941-6030 Fax : ++49-9941-603222 E-mail : reiner.dassing@bkg.bund.de Secondary Contact Contact Name : Uwe Hessels Telephone (primary) : ++49-9941-603208 Telephone (secondary) : ++49-9941-6030 Fax : ++49-9941-603222 E-mail : uwe.hessels@bkg.bund.de Additional Information : 13. More Information Primary Data Center : BKG Secondary Data Center : TIGO URL for More Information : www.bkg.bund.de, www.tigo.cl Hardcopy on File Site Map : Site Diagram : Horizon Mask : Monument Description : Site Pictures : Additional Information : Antenna Graphics with Dimensions ASH700936E +---------+ / + \ <-- 0.1280 L2 | + | <-- 0.1100 L1 +-----------------+-------------+------------------+ <-- 0.1008 TCR | | | | | | | | +-+--------------------------------------------------+-+ <-- 0.0378 +-------------------+-------------+--------------------+ <-- 0.0348 BCR | | | | +------x------+ <-- 0.0000 BPA=ARP <-- 0.3794 --> ARP: Antenna Reference Point L1 : L1 Phase Center L2 : L2 Phase Center TCR: Top of Chokering BCR: Bottom of Chokering TGP: Top of Ground Plane BGP: Bottom of Ground Plane TPA: Top of Preamplifier BPA: Bottom of Preamplifier TOP: Top of Pole All dimensions are in meters.