IGS Station Mail          10 Nov 13:19:55 PST 2004      Message Number 237
******************************************************************************

Author: Stephen Delahunt
 
Four Character ID        : STJO
IERS DOMES Number        : 40101M001
City or Town             : ST. JOHN'S
State or Province        : Newfoundland and Labrador
Country                  : CANADA
Agency                   : NRCan/GEODETIC SURVEY OF CANADA

ADVISORY CORRECTION:
====================

Reference mail: "IGSSTATION-234"

On 04Nov08 I made two erroneous statements I would like to correct:  

 - The 04Nov08 14:44 UTC STJO clock switch was from a maser to a RUBIDIUM.
 - Clock Steering was not applied to the RUBIDIUM.

The station was returned to the MASER clock 04Nov10 20:00 UTC

A revised site log has been posted.