Message-ID: <5ACEEE96F4F9D41190790002A528B51E78E5E9@s0-ott-x11.nrn.nrcan.gc.ca> From: =?ISO-8859-1?Q?=22Ferland=2C_R=E9mi=22?= To: "'igsmail@igscb.jpl.nasa.gov'" Subject: [IGSMAIL-4148]: FW: FAIR in SINEX Products Date: Wed, 6 Nov 2002 10:12:34 -0500 Sender: owner-igsmail Precedence: bulk ****************************************************************************** IGS Electronic Mail 06 Nov 08:57:58 PST 2002 Message Number 4148 ****************************************************************************** Author: R. Ferland Dear IGS Colleagues, To follow on the IGS mail distributed earlier this week by Geoff Blewitt reporting about a seismic event and potential displacement at FAIR. A displacement was later on reported by M. Heflin based on the rapid products. If the pre and post seismic estimates at FAIR are included in the weekly SINEX combination, they must be reported separately with distinct solution #. The epoch blocks should allow to distinguish which solution belong to what epoch. Since the station is also part of the reference frame network, it should not be used any more for the solution alignment as also mentioned by Geoff. This will be confirmed when more data is available with the final products. The station will not be used in the IGS weekly SINEX combination until the displacement is confirmed. In the alignment of the cumulative solution, the station will continue to be used for alignment, but only using the pre-seismic data. Best Regards, Remi,